Aquilion 16 (TSX-101A) service procedures & guides
197 field-service procedure previews for the Canon Medical (Toshiba) Aquilion 16 (TSX-101A) — what each procedure does, tools/parts and safety. The full step-by-step lives in the FSELIB service manual.
Console (Diagnostics) · 2
Console (Operation) · 2
Console (Recon) · 2
Gantry/Rotation · 7
Adjust the MR sensor and MR sensor PWB20 stepsReplace the MR sensor and MR sensor PWB12 stepsReplace the rotation-direction photo sensor unit6 stepsGantry rotation interlock when servicing with cover open11 stepsGantry rotation speed check and fine adjustment7 stepsGantry rotation system operation and troubleshooting (S/N Axxxxx)0 stepsGantry rotation system operation and troubleshooting (S/N Bxxxxx)5 steps
Couch/Control · 9
Set couch autoslide movement range and zero-clear time4 stepsPatient couch control troubleshooting (CBTB-016A/016B)11 stepsAdjust couch height and projector angle displays10 stepsSet couch horizontal movement absolute-value control data9 stepsCouch slide servo amplifier operation and maintenance tool (CBTB-016A/016B)10 stepsSet couch-top sliding fine-adjustment function5 stepsCheck the couch-top speed2 stepsSet couch vertical movement stop position (auto-set mode)5 stepsSelect footswitch mode (CBTB-016A/016B)5 steps
Gantry-Couch/Control · 2
Couch/Table (Longitudinal) · 6
Adjust the slide drive belt tension6 stepsAdjust the couch-top supporting rollers (level and sway)4 stepsReplace the horizontal (longitudinal) drive unit5 stepsReplace the couch slide servo amplifier3 stepsTroubleshoot: slide stop accuracy, roller ride, rattle/sway, noise, and no in/out motion0 stepsTroubleshoot: couch top will not slide into/out of the gantry opening13 steps
Couch/Table (Vertical) · 7
Adjust the vertical (lowering) motion speed5 stepsChange the vertical stop positions (height photosensor adjustment)2 stepsJack Up the Patient Couch When It Will Not Rise From the DOWN Limit4 stepsLower the Patient Couch from a Raised Position After a Failure (200 VAC Jig)4 stepsReplace the hydraulic unit (cylinder, pump, oil tank)25 stepsRoute the internal cables at the lifting linkage8 stepsTroubleshoot: couch will not go up/down and oil leakage9 steps
Couch/Table (Clutch/Brake) · 1
Couch/Table · 10
Partially disassemble the patient couch for carrying-in (narrow route)5 stepsReset the overcurrent relay (horizontal and vertical motors)6 stepsFine-adjust the couch position using CT images13 stepsPrepare the couch and perform rough positioning with the projector16 stepsSecure the couch, install the footswitch, fit covers and set the height indicator18 stepsCarry the patient couch in tilted, on a triangular stand (narrow route or small elevator)11 stepsGantry/couch interlock test procedures21 stepsPatient couch cleaning, headrest and horizontal-belt tension checks — 2.1-2.518 stepsCouch hydraulic leakage, lubrication, tightening, natural-fall, DC power and sensor checks — 2.12-2.191 stepsCouch cable, movement-accuracy, free-operation, interlock and limit checks — 2.6-2.1116 steps
Couch/Table (Covers) · 2
DAS · 13
Acquire calibration data (NRA / air calibration)2 stepsCheck the DAS supply voltage (PCN1-PCN4)8 stepsRun the DCA offset data check (X-ray inhibit)7 stepsRun the DCA test-pattern check and read the Data Check menu3 stepsRun the DCA X-ray output check9 stepsDiagnose integrator-, gain-, and slice-thickness-dependent abnormalities4 stepsReplace a DAS PWB (Converter-16 / Control-16)7 stepsTroubleshoot ring-image artifacts18 stepsTroubleshoot large image SD13 stepsTroubleshoot shifted CT number13 stepsTroubleshoot streak-shower artifacts0 stepsData acquisition trouble ↔ cause matrix (Table 5.4-2)0 stepsDAS troubleshooting — safety notices, work precautions, tools6 steps
Detector/DAS · 5
Replace the main detector array29 stepsReplace the REF detector10 stepsCalibration data acquisition (NRA / air calibration)18 stepsData acquisition system checks: temperature, connectors, line-voltage pins, fuses, fan, window — 4.1-4.60 stepsData transfer unit operation and cleaning check (GCIFA PWB) — 5.1/5.26 steps
Detector temperature control · 1
Gantry — Covers & access · 9
Adjust the operating panel acrylic cover clearance4 stepsClean the FRP covers and remove the wedge/slit optical system7 stepsOpen and close the gantry front cover10 stepsRemove and remount the base and under covers13 stepsRemove and mount the dome cover5 stepsRemove and mount the Mylar sheet (ring)5 stepsRemove and remount the side cover4 stepsRemove and remount the rear cover (with/without dome)9 stepsRemove, remount or withdraw the upper cover10 steps
Gantry — Optical / projector · 2
Gantry — Rotation drive · 2
Gantry — Tilt drive · 4
Gantry — Slip ring & brushes · 4
Gantry — X-ray tube · 2
Gantry — Tilt/Stand · 2
Gantry — Slip ring · 2
Gantry — X-ray beam optics · 2
Gantry — Troubleshooting · 1
Installation · 6
Bring the patient couch and console into position9 stepsChecks before turning on the power7 stepsBasic disassembly and carrying-out of the system13 stepsFinal gantry-couch relationship check, system test and calibration data14 stepsIntegrated test — scan operation and image quality6 stepsPre-delivery: mount couch accessories, clean and fill the QC sheet10 steps
Gantry · 24
Bring the gantry into the scanner room15 stepsAlign the slip-ring brush assemblies10 stepsClean the large-current slip ring (LCSR)21 stepsOperational checks of gantry, couch, detector and X-ray tube18 stepsInstall optional units and mount the covers6 stepsClean dome internal-projector window and check Mylar ring mounting — 1.345 stepsGantry fan-noise check and filter cleaning — 1.44/1.456 stepsFault-current protective breaker (NFB2) operation check — 1.436 stepsGantry mounting-bolt/screw tightening checks (items 1.1-1.24, paint-mark method)4 stepsGantry rotation operation check (scan speeds) — 1.329 stepsGantry safety-mechanism and interlock checks — 1.36/1.377 stepsGantry terminal-board looseness, screw/nut, cable and final cleaning checks — 1.55-1.588 stepsVisual check of GTS unit and rotation servo unit interiors — 1.49/1.507 stepsOff-delay timer (X-ray tube cooling protection) setting and function check — 1.485 stepsOperating-panel and footswitch operation & switch-clearance checks — 1.46/1.477 stepsClean gantry photo-sensors (rotation, wedge, slit, rotational-direction detectors) — 1.255 stepsPositioning projector lamp: replacement, cleaning and internal/external/median alignment — 1.3317 stepsGantry safety-circuit operation checks via KGTSM (tilt/vertical/horizontal, runout, rotation error) — 1.38/1.39/1.4013 stepsSlipring brush abrasion check and brush replacement — 1.3014 stepsClean the large-current slip ring and adjust brush alignment — 1.2932 stepsSlit operation check (slice/slit width table) and wedge slide check & lubrication — 1.27/1.288 stepsTilt cable routing (cable movement) check — 1.353 stepsTilt power cylinder and gas spring abnormal-sound/oil-leak check — 1.265 stepsTilt limit switch check and tilt-angle adjustment — 1.316 steps
Power · 4
Recon/Console · 3
X-ray & HV · 6
X-ray tube If adjustment (remote)11 stepsCheck phantom position, run the test scan and check tube alignment10 stepsX-ray tube alignment (front/rear and left/right)12 stepsX-ray HV: XC battery, charge/discharge, starter output, cables, SRU bolts, tube bellows — 3.14-3.1919 stepsX-ray tube/heat-exchanger leakage, rotor resistance and cooling-fan checks — 3.1-3.917 stepsGenerator troubleshooting table (phenomena and countermeasures)3 steps
Network/DICOM · 1
Gantry — Site installation · 1
Interlocks · 1
Maintenance · 2
Data Transfer (MUDAT) · 7
Diagnose an abnormal image caused by the MUDAT1 stepsDAS test mode and View Trigger (VT) check9 stepsDisassemble the MUDAT7 stepsCheck LED luminescence with the IR converter (ROT and SOT)7 stepsManual check and console test for locating MUDAT faults14 stepsOperation check after MUDAT work0 stepsTroubleshoot control-system data communication errors20 steps
Software / Alignment · 2
Software / Storage & RAID · 2
Software / Backup & Restore · 2
Software / Calibration · 1
Software / DCA · 5
Start and stop DCA (Data Collection Analyzer) and its function set4 stepsCheck DAS offset data with X-ray inhibited (JP3 test mode)8 stepsRun DAS/GCIF/offset/output test patterns and read the results3 stepsIsolate an abnormal channel or artifact using the DCA sinogram14 stepsCheck X-ray output with the DCA (acquisition, mean calculation, graph)9 steps
Software / Error Analysis · 1
Software / Installation · 4
Set up an imager (DICOM or Toshiba protocol) with the Setup Utility preset tool7 stepsInitialize the system: model/tube setup, special config, RDD/RAID, host name25 stepsSoftware installation overview: methods 1/2/3, required media, site backup8 stepsInstall the system software from CD-ROM (boot, format, Windows 2000 setup)20 steps
Software / Network & DICOM · 2
Software / Options & Licensing · 3
Software / Exam Scheduler · 1
Software / System Setup · 1
X-ray & HV (X-ray tube) · 4
X-ray & HV (XC control) · 7
If (filament current) adjustment procedure11 stepsXC Maintenance Program: outline, connection and menu1 stepsXC Maintenance Program: Signal Show (kV/mA/If/HV waveforms)1 stepsXC Maintenance Program: block test, exposure/running test, debug monitor and screens9 stepsSet up PWBs and adjust the kV waveform (VR3)4 stepsTroubleshoot XC operation, cable interlock and starter communication faults0 stepsReplace the XC PWB backup battery4 steps
X-ray & HV (SRU generator) · 7
Identify the defective inverter before replacement0 stepsReplace the inverter in the SRU generator5 stepsRemove and remount the SRU unit11 stepsError-cause identification flowchart (block test to isolate SRU/HV cable)4 stepsTroubleshoot inverter temperature error and anode/cathode arc0 stepsTroubleshoot kV/mA output faults (Over mA, Under mA, HV overcurrent, Under kV)0 stepsTroubleshoot SRU status error and identify the faulty inverter block0 steps