InstallationSoftware / InstallationInstallationInstall
Software installation overview: methods 1/2/3, required media, site backup
Before a CD-ROM goes anywhere near the drive, three installation methods make three different promises about what survives on the system and image disks — this atom decodes which one to pick, exactly what each one needs on hand, and the one thing every real install does first: saving the site-specific information to MO.
Applies to
Aquilion 16 (TSX-101A) — system software volume 2D260-074E*B, source p.137-138, covering source Chapter 9, section 9.1 "Outline" (the three installation methods), the introduction to section 9.2 "Installation Methods 1 and 2," section 9.2.1 "Preparation," and section 9.2.2 "Saving the site-specific information on an MO cassette." Source states this manual describes only Methods 1 and 2 in procedural detail; Method 3 (make-update) is itemized here but not carried into a step-by-step procedure anywhere in this volume. This atom does not cover the step-by-step install itself — that is source's own next section, 9.2.3 (see Related, toshiba-ct-aquilion16-software-install-system-software).
Personnel
Basic — choosing among three source-defined installation methods and running a menu-driven site-information backup ([Maintenance Utility] > [Backup Tool]); no board-level work, no special tooling beyond handling CD-ROMs and an MO cassette. The disk-initializing install steps this preparation leads into are covered in a separate section (9.2.3; see Related). (Skill assessment derived from content — not an OEM-stated skill level.)
Steps
8 steps
Source
2D260-074E*B p.137-138
Full step-by-step for Software installation overview: methods 1/2/3, required media, site backup
All 8 steps are documented in the FSELIB Aquilion 16 (TSX-101A) service manual — re-authored, web-first, with the real figures from the source.
Open the full procedureRelated Software / Installation guides
Set up an imager (DICOM or Toshiba protocol) with the Setup Utility preset tool7 stepsInitialize the system: model/tube setup, special config, RDD/RAID, host name25 stepsInstall the system software from CD-ROM (boot, format, Windows 2000 setup)20 stepsRun the console malfunction-diagnosis program (hwtest)0 stepsRun the independent MHR PWB test (diagnostics) from the RTM terminal4 stepsRemove the host PC unit (PX74-07959 GR-1/GR-2)4 steps
View all Aquilion 16 (TSX-101A) guidesSource: 2D260-074E*B p.137-138. Preview re-authored by FSELIB — the full procedure with figures and steps is in the paid service manual.