Pular para o conteúdo principal
Canon Medical·🔬CT Scanner

Aquilion 16 (TSX-101A) Service Manual

FSELIB authored service atoms

FSELIB authored service atoms for the Canon Medical (Toshiba) Aquilion 16 CT scanner: gantry, patient couch, gantry/couch control, X-ray, DAS, diagnostics, system software, console, installation and maintenance. Web-first, real figures at 300 dpi. This service manual covers installation, calibration, troubleshooting and maintenance procedures for the Canon Medical Aquilion 16 (TSX-101A).

Also known as: Toshiba, Canon, Aquilion, Aquilion 16, TSX-101A

Start free trial →

Access 589+ technical service manuals — 7-day free trial, no credit card required.

589+ manuals · 8+ manufacturers · CT, MRI, Mammography, X-Ray & more

Technical Specifications

ManufacturerCanon Medical
Equipment TypeCT Scanner
Part Number
2D201-059/061/062/063/064/065/074/079EN, 2C201-160, 2Y201-061
RevisionFSELIB 2026-07
Models Covered
Aquilion 16TSX-101A

Table of Contents

From actual manual
11000BASE switching HUB — PowerConnect 2708 (BSX74-1896)
Start free trial →
2Navibox CNN-panel external cable map (CPU BOX and REC BOX)
Start free trial →
3REC BOX connector pinouts (DAS, CONT FC-AL, SCONT1/2)
Start free trial →
4Remove the host PC unit (PX74-07959 GR-1/GR-2)
Start free trial →
5Remove the host PC unit (PX74-08766 GR-1/GR-2)
Start free trial →
6Host PC unit specs and internals (PX74-07959 GR-1/GR-2)
Start free trial →
7Host PC unit specs and internals (PX74-08766 GR-1/GR-2)
Start free trial →
8Run the independent MHR PWB test (diagnostics) from the RTM terminal
Start free trial →
9Console keyboard and control PWB (connectors, SSW1)
Start free trial →
10Run the console malfunction-diagnosis program (hwtest)
Start free trial →
11MHR fast-reconstruction PWBs: types and architecture
Start free trial →
12MHR preprocessing and reconstruction data paths (slot map)
Start free trial →
13MHR PWB LEDs and flash-boot jumper setting
Start free trial →
14Magneto-optical disk (MOD) drive: specs and parts
Start free trial →
15MOD drive jumper block, DIP switch settings, and manual eject
Start free trial →
16Console operation section and monitors
Start free trial →
17CPU BOX connector pinouts (VOICE, XC-GTS, FC-AL, SCONT1/2, keyboards, monitor)
Start free trial →
18RTM-D interface PWB (dual-port RAM, W1, LEDs)
Start free trial →
191000BASE switching HUB — PowerConnect 2608 (BSX74-1711)
Start free trial →
20How this console manual is organized and the TSX-101A service-manual set
Start free trial →
21Console mouse: types, cleaning, and connector pinout
Start free trial →
22Console Fuse List (Ratings, Locations, and TS Drawing Numbers)
Start free trial →
23Console power controller: power-ON / power-OFF sequence
Start free trial →
24Raw Data Disk Array — Medea JBOD (config, LEDs, disk removal)
Start free trial →
25Raw Data Disk Array — Rorke Data JBOD (config, LEDs, setup)
Start free trial →
26Remove and install an RDD fan unit (Rorke Data)
Start free trial →
27Remove and install an RDD disk/power-supply unit (Rorke Data)
Start free trial →
28REC BOX internal layout and power CONT
Start free trial →
29RTM real-time manager and RTM-M PWB
Start free trial →
30Console service safety precautions (DANGER / WARNING / CAUTION)
Start free trial →
31Take static-electricity countermeasures before handling console PWBs
Start free trial →
32Adjust the SS/ADI intercom audio (speaker/mic VRs)
Start free trial →
33SS/ADI3 / SS/ADI4 PWB: switches, LEDs, connectors
Start free trial →
34Console power and signal connection diagrams (CPU BOX / REC BOX)
Start free trial →
35Console (CKCN-012C) overview and CPU BOX internal layout
Start free trial →
36Console control/data flow at boot and during scanning
Start free trial →
37Navibox architecture and console block diagram
Start free trial →
38Maintain and inspect the clutch/brake assembly
Start free trial →
39Lower covers: base covers and the flexible (bellows) cover
Start free trial →
40Remove and install the patient couch upper covers (handle, front, rear, side, rail, maintenance, couch-top bottom, and frame bottom covers)
Start free trial →
41Replace the flexible (bellows) cover
Start free trial →
42Upper covers — part identification and names
Start free trial →
43Adjust the couch-top supporting rollers (level and sway)
Start free trial →
44Adjust the Horizontal (Slide) Motion Speed - Servo Amplifier Parameters
Start free trial →
45Adjust the slide drive belt tension
Start free trial →
46Replace the couch slide servo amplifier
Start free trial →
47Replace the horizontal (longitudinal) drive unit
Start free trial →
48Troubleshoot: couch top will not slide into/out of the gantry opening
Start free trial →
49Patient couch service safety precautions (signal words, DANGER/WARNING/CAUTION, ESD)
Start free trial →
50Couch top (CFRP tabletop) component reference
Start free trial →
51Longitudinal (Slide) Movement Drive Unit and Couch-Top Moving Frame - Theory
Start free trial →
52Main patient couch unit structure and main frame unit
Start free trial →
53Patient couch overview and operation (SLIDE / HEIGHT block diagram)
Start free trial →
54Patient Couch Vertical Movement Mechanism and Hydraulic Drive — Theory of Operation
Start free trial →
55Partially disassemble the patient couch for carrying-in (narrow route)
Start free trial →
56Reset the overcurrent relay (horizontal and vertical motors)
Start free trial →
57Troubleshoot: slide stop accuracy, roller ride, rattle/sway, noise, and no in/out motion
Start free trial →
58Adjust the vertical (lowering) motion speed
Start free trial →
59Change the vertical stop positions (height photosensor adjustment)
Start free trial →
60Jack Up the Patient Couch When It Will Not Rise From the DOWN Limit
Start free trial →
61Lower the Patient Couch from a Raised Position After a Failure (200 VAC Jig)
Start free trial →
62Replace the hydraulic unit (cylinder, pump, oil tank)
Start free trial →
63Route the internal cables at the lifting linkage
Start free trial →
64Troubleshoot: couch will not go up/down and oil leakage
Start free trial →
65DAS data acquisition sequence timing
Start free trial →
66DAS test-mode data patterns (IntegA / IntegB reference)
Start free trial →
67Detector / REF to DAS channel and Converter-16 slot map
Start free trial →
68Control-16 ↔ OPCONTA interface signals and DAS gain selection
Start free trial →
69Converter-16 and Control-16 PWBs — architecture, DIP switches, LEDs, fan monitor
Start free trial →
70Replace a DAS PWB (Converter-16 / Control-16)
Start free trial →
71DAS I/O cable connector pinout (CNN1/CNN2/CNN3, 68-pin)
Start free trial →
72Run the DCA offset data check (X-ray inhibit)
Start free trial →
73Replace the main detector array
Start free trial →
74Replace the REF detector
Start free trial →
75DAS power supply (EWS600, +5.7 V)
Start free trial →
76Check the DAS supply voltage (PCN1-PCN4)
Start free trial →
77Acquire calibration data (NRA / air calibration)
Start free trial →
78Data acquisition section — safety precautions
Start free trial →
79ESD / static-electricity countermeasures for DAS PWB service
Start free trial →
80Repair precautions before replacing DAS parts
Start free trial →
81Configure the detector temperature controller after replacement (AXC004-01 / -02)
Start free trial →
82DAS overall operation and data flow
Start free trial →
83DAS section configuration and component layout
Start free trial →
84Main detector array and channel bundling
Start free trial →
85DAS troubleshooting — safety notices, work precautions, tools
Start free trial →
86Data acquisition trouble ↔ cause matrix (Table 5.4-2)
Start free trial →
87Diagnose integrator-, gain-, and slice-thickness-dependent abnormalities
Start free trial →
88Run the DCA test-pattern check and read the Data Check menu
Start free trial →
89Run the DCA X-ray output check
Start free trial →
90Troubleshoot streak-shower artifacts
Start free trial →
91Troubleshoot large image SD
Start free trial →
92Troubleshoot ring-image artifacts
Start free trial →
93Troubleshoot shifted CT number
Start free trial →
94MUDAT composition: sub-units and PWBs
Start free trial →
95Disassemble the MUDAT
Start free trial →
96DAS test mode and View Trigger (VT) check
Start free trial →
97Data-transfer diagnostic tools and IF-unit locations
Start free trial →
98Data-transfer error catalog (25 error types)
Start free trial →
99Diagnose an abnormal image caused by the MUDAT
Start free trial →
100GCIFA console test patterns (segments 1-16)
Start free trial →
101GCIFA error display panel (NORMAL and I. MODE)
Start free trial →
102Manual check and console test for locating MUDAT faults
Start free trial →
103Operation check after MUDAT work
Start free trial →
104Raw-data / extra-data structure and MUDAT error bitfields
Start free trial →
105Check LED luminescence with the IR converter (ROT and SOT)
Start free trial →
106OPCONTA PWB: DIP switches, fuses and layout
Start free trial →
107Channel switching and Disable (non-rotation) scan setup
Start free trial →
108GCIFA-D PWB: switches, jumpers, LEDs and diagnosis
Start free trial →
109GCIFA PWB: DIP switches, fuses and test-data output
Start free trial →
110GCIFA PWB LED reference
Start free trial →
111OPCONTA PWB LED reference
Start free trial →
112Safety precautions for MUDAT / data-transfer service
Start free trial →
113Static-electricity (ESD) precautions before handling PWBs
Start free trial →
114How the gantry data-transfer section works (overview)
Start free trial →
115IF unit theory: OPCONTA, GCIFA and GCIFA-D
Start free trial →
116MUDAT physical layout: rotation and stationary sections
Start free trial →
117MUDAT terminology and abbreviations
Start free trial →
118Optical emitting and receiving sections (theory)
Start free trial →
119Troubleshoot control-system data communication errors
Start free trial →
120Adjust the operating panel acrylic cover clearance
Start free trial →
121Clean the FRP covers and remove the wedge/slit optical system
Start free trial →
122Gantry covers map and cover-open access views
Start free trial →
123Open and close the gantry front cover
Start free trial →
124Remove and mount the dome cover
Start free trial →
125Remove and remount the base and under covers
Start free trial →
126Remove and remount the side cover
Start free trial →
127Remove, remount or withdraw the upper cover
Start free trial →
128Remove and mount the Mylar sheet (ring)
Start free trial →
129Remove and remount the rear cover (with/without dome)
Start free trial →
130Important fastening assemblies and tightening torques
Start free trial →
131Adjust the projectors (inner, median, external)
Start free trial →
132Replace the projector lamps (median, internal, side)
Start free trial →
133Adjust the rotation balance (weights)
Start free trial →
134Troubleshoot the rotation section
Start free trial →
135ESD countermeasures for service work (wrist strap, antistatic kit)
Start free trial →
136Gantry mechanism service safety precautions (signal words, DANGER/WARNING/CAUTION)
Start free trial →
137Align the slip ring brushes with the alignment jig
Start free trial →
138Clean the large-current slipring and brush assemblies
Start free trial →
139Repair a damaged large-current slip ring (emergency)
Start free trial →
140Replace the large-current slip ring brushes
Start free trial →
141Replace the SRU (SRU-H / SRU-L / SRU-POWER)
Start free trial →
142Gantry mechanism outline and unit configuration
Start free trial →
143How the main frame works: slip ring and rotation drive
Start free trial →
144How the wedge filter and slit units work (with slit-width table)
Start free trial →
145How the X-ray beam control and tube-mounting units work
Start free trial →
146Adjust the tilt angle (stop positions and limits)
Start free trial →
147How the Stand (Tilt) Unit Works
Start free trial →
148Lubricate the tilt drive unit
Start free trial →
149Manually tilt the gantry in case of malfunction
Start free trial →
150Replace the tilt gas spring
Start free trial →
151Replace the tilt power cylinder
Start free trial →
152Troubleshoot the slip ring section
Start free trial →
153Gantry troubleshooting approach and symptom index
Start free trial →
154Troubleshoot the slit section
Start free trial →
155Troubleshoot the tilt section
Start free trial →
156Troubleshoot the wedge section
Start free trial →
157Align the X-ray tube (front/rear and left/right)
Start free trial →
158Replace the X-ray tube (side and bottom jig methods)
Start free trial →
159Adjust couch height and projector angle displays
Start free trial →
160Check the couch-top speed
Start free trial →
161Check the KGTSM PWB safety circuit
Start free trial →
162Couch slide servo amplifier alarm codes and parameter list (CBTB-016A/016B)
Start free trial →
163Couch slide servo amplifier operation and maintenance tool (CBTB-016A/016B)
Start free trial →
164DD motor servo amplifier error display (S/N A and S/N B panels)
Start free trial →
165Interlocks: positions and operation interlock tables
Start free trial →
166KGTSM detailed error and DD-motor status codes
Start free trial →
167KGTSM message catalog: typical, DD-motor errors, terminal log
Start free trial →
168KGTSM PWB: switches, connectors, LEDs, test pins
Start free trial →
169KGTSM timer checks and timer errors
Start free trial →
170Magnet conductor covers and acquisition additional-data items
Start free trial →
171OPCONTA, GCIFA and KGTSP PWB settings and connectors
Start free trial →
172Patient couch control troubleshooting (CBTB-016A/016B)
Start free trial →
173Patient couch sliding servo amplifier (CBTB-014A): operation and parameters
Start free trial →
174Post-replacement checks and KGTSM system setting switches
Start free trial →
175Reading KGTSM cyclic/return status data (field decode)
Start free trial →
176Select footswitch mode (CBTB-016A/016B)
Start free trial →
177Set couch autoslide movement range and zero-clear time
Start free trial →
178Set couch horizontal movement absolute-value control data
Start free trial →
179Set couch vertical movement stop position (auto-set mode)
Start free trial →
180Set couch-top sliding fine-adjustment function
Start free trial →
181Use the KGTSM maintenance panel
Start free trial →
182Gantry Fuse List and Mounting Locations (S/N Axxxxx and S/N Bxxxxx)
Start free trial →
183Adjust the MR sensor and MR sensor PWB
Start free trial →
184Gantry rotation interlock when servicing with cover open
Start free trial →
185Gantry rotation speed check and fine adjustment
Start free trial →
186Gantry rotation stop position (Aquilion)
Start free trial →
187Gantry rotation system operation and troubleshooting (S/N Axxxxx)
Start free trial →
188Gantry rotation system operation and troubleshooting (S/N Bxxxxx)
Start free trial →
189Gantry X-ray tube position information (Aquilion)
Start free trial →
190Replace the MR sensor and MR sensor PWB
Start free trial →
191Replace the rotation-direction photo sensor unit
Start free trial →
192Safety precautions for gantry/couch control service
Start free trial →
193Control flow: drive section and data-acquisition
Start free trial →
194Gantry Power-Supply Sequence
Start free trial →
195Gantry/couch control section: architecture and targets of control
Start free trial →
196Optical system operation: wedge and slit reference-position control and timeouts
Start free trial →
197Tilt encoder value vs actual angle lookup table
Start free trial →
198Bring the patient couch and console into position
Start free trial →
199Check phantom position, run the test scan and check tube alignment
Start free trial →
200Place the couch and console and install the RDD HDDs
Start free trial →
201Gantry/couch interlock test procedures
Start free trial →
202KGTSM terminal settings for the patient couch
Start free trial →
203Fine-adjust the couch position using CT images
Start free trial →
204Install optional units and mount the covers
Start free trial →
205DICOM network setting (IP registration and environment tool)
Start free trial →
206Basic disassembly and carrying-out of the system
Start free trial →
207Connect warning lamp, door switch and inter-unit cables
Start free trial →
208Inter-unit cable diagram and field-wiring terminal board connection
Start free trial →
209Final gantry-couch relationship check, system test and calibration data
Start free trial →
210X-ray tube If adjustment (remote)
Start free trial →
211Imager preset setup and operational check
Start free trial →
212Integrated test — scan operation and image quality
Start free trial →
213Using the KGTSM maintenance panel
Start free trial →
214Network installation conditions (packet-filtering table)
Start free trial →
215Calibration data acquisition (NRA / air calibration)
Start free trial →
216Operational checks of gantry, couch, detector and X-ray tube
Start free trial →
217Installation flow overview and component check
Start free trial →
218Connect the console network / imager (physical LAN)
Start free trial →
219Power-supply mode setting and protective-timer checks
Start free trial →
220Power-on sequence and AC/DC voltage checks
Start free trial →
221Pre-delivery: mount couch accessories, clean and fill the QC sheet
Start free trial →
222Checks before turning on the power
Start free trial →
223Gantry rotation interlock (cover switch / SW120)
Start free trial →
224Gantry/couch interlock positions and interlock table
Start free trial →
225Installation safety precautions and signal-word glossary
Start free trial →
226Set up HyperTerminal for KGTSM/GTS access
Start free trial →
227Position, level and anchor the gantry
Start free trial →
228Prepare the couch and perform rough positioning with the projector
Start free trial →
229Secure the couch, install the footswitch, fit covers and set the height indicator
Start free trial →
230Bring the gantry into the scanner room
Start free trial →
231Align the slip-ring brush assemblies
Start free trial →
232Clean the large-current slip ring (LCSR)
Start free trial →
233System specifications, operating conditions and installation tool list
Start free trial →
234Confirm console startup, check the audio system and set up the console software
Start free trial →
235Carry the patient couch in tilted, on a triangular stand (narrow route or small elevator)
Start free trial →
236X-ray tube alignment (front/rear and left/right)
Start free trial →
237Gantry fan-noise check and filter cleaning — 1.44/1.45
Start free trial →
238Data acquisition system checks: temperature, connectors, line-voltage pins, fuses, fan, window — 4.1-4.6
Start free trial →
239Data transfer unit operation and cleaning check (GCIFA PWB) — 5.1/5.2
Start free trial →
240Whole-system image-quality tests: noise, CT number (TOS phantom), streak/artifact — 7.1-7.3
Start free trial →
241Gantry mounting-bolt/screw tightening checks (items 1.1-1.24, paint-mark method)
Start free trial →
242Interlock test method: outline, interlock positions and full interlock table — A.1-A.3
Start free trial →
243Interlock test procedures: HEIGHT/TILT/SLIDE limits, tape/mat switches, auto-home, auto-set — A.4
Start free trial →
244Couch-height, tilt-angle, rotation-speed and couch-movement-speed checks — 1.51-1.54
Start free trial →
245Gantry internal AC and DC voltage checks — 1.41/1.42
Start free trial →
246Off-delay timer (X-ray tube cooling protection) setting and function check — 1.48
Start free trial →
247Operating-panel and footswitch operation & switch-clearance checks — 1.46/1.47
Start free trial →
248Clean dome internal-projector window and check Mylar ring mounting — 1.34
Start free trial →
249Clean gantry photo-sensors (rotation, wedge, slit, rotational-direction detectors) — 1.25
Start free trial →
250Positioning projector lamp: replacement, cleaning and internal/external/median alignment — 1.33
Start free trial →
251Slit operation check (slice/slit width table) and wedge slide check & lubrication — 1.27/1.28
Start free trial →
252Preventive maintenance scope and system composition (TSX-101A/F, /G)
Start free trial →
253Couch cable, movement-accuracy, free-operation, interlock and limit checks — 2.6-2.11
Start free trial →
254Couch hydraulic leakage, lubrication, tightening, natural-fall, DC power and sensor checks — 2.12-2.19
Start free trial →
255Patient couch cleaning, headrest and horizontal-belt tension checks — 2.1-2.5
Start free trial →
256X-ray HV: XC battery, charge/discharge, starter output, cables, SRU bolts, tube bellows — 3.14-3.19
Start free trial →
257X-ray output electrical checks: kV/mA, tube-current waveform, exposure time, line voltage — 3.10-3.13
Start free trial →
258X-ray tube/heat-exchanger leakage, rotor resistance and cooling-fan checks — 3.1-3.9
Start free trial →
259Console cleaning, fans, PC input and DC power-supply checks — 6.1-6.11
Start free trial →
260Periodic inspection schedule: full item list with 3M/6M/1Y/2Y intervals
Start free trial →
261Fault-current protective breaker (NFB2) operation check — 1.43
Start free trial →
262Gantry terminal-board looseness, screw/nut, cable and final cleaning checks — 1.55-1.58
Start free trial →
263Before inspection: tools, workers, standard precautions, cleaning and disinfection
Start free trial →
264Gantry rotation operation check (scan speeds) — 1.32
Start free trial →
265Visual check of GTS unit and rotation servo unit interiors — 1.49/1.50
Start free trial →
266Gantry safety-circuit operation checks via KGTSM (tilt/vertical/horizontal, runout, rotation error) — 1.38/1.39/1.40
Start free trial →
267Gantry safety-mechanism and interlock checks — 1.36/1.37
Start free trial →
268Gantry servicing access and safety (cover open, rotation lock, supporting poles)
Start free trial →
269Maintenance safety precautions: signal words, electrical, laser, slipring and rotation hazards
Start free trial →
270Clean the large-current slip ring and adjust brush alignment — 1.29
Start free trial →
271Slipring brush abrasion check and brush replacement — 1.30
Start free trial →
272Tilt cable routing (cable movement) check — 1.35
Start free trial →
273Tilt limit switch check and tilt-angle adjustment — 1.31
Start free trial →
274Tilt power cylinder and gas spring abnormal-sound/oil-leak check — 1.26
Start free trial →
275Adjust left/right X-ray tube alignment with air + pin phantom
Start free trial →
276Back up, restore and format site information on MO with the Backup Tool
Start free trial →
277Back up and restore calibration data (RDD ↔ HDD ↔ MOD)
Start free trial →
278Enable temporary 8-/16-slice conventional scan with the ExtendSeg command
Start free trial →
279Run DAS/GCIF/offset/output test patterns and read the results
Start free trial →
280DCA main window: reference of every function and operating control
Start free trial →
281Check DAS offset data with X-ray inhibited (JP3 test mode)
Start free trial →
282Check X-ray output with the DCA (acquisition, mean calculation, graph)
Start free trial →
283Isolate an abnormal channel or artifact using the DCA sinogram
Start free trial →
284Configure DICOM connectivity: hosts, services, transfer syntax, timeouts, language
Start free trial →
285Worked DICOM setup example (Aquilion to ALATOVIEW)
Start free trial →
286Collect error logs: view and save the EventLog for analysis
Start free trial →
287Configure Exposure Record output and calculation items
Start free trial →
288Adjust front/rear X-ray tube alignment (Scan to calculate)
Start free trial →
289Configure Scheduler FTP Acquisition and FTP Output
Start free trial →
290Handle and verify the options hardware license (USB dongle)
Start free trial →
291Initialize the image disk (via supplied CD-ROM or Windows Disk Manager)
Start free trial →
292Set up an imager (DICOM or Toshiba protocol) with the Setup Utility preset tool
Start free trial →
293Examination Scheduler Initial Setting screens (1 and 2) field reference
Start free trial →
294Initialize the system: model/tube setup, special config, RDD/RAID, host name
Start free trial →
295MOD service reference: mount, unmount and format the magneto-optical drive
Start free trial →
296Acquire NRA and air calibration data (setup, procedure, flow, deletion)
Start free trial →
297Manage options software licenses: 90-Day Trial, load/unload, status
Start free trial →
298CT software architecture, login accounts, disk partitions and service media
Start free trial →
299Configure CSV output, Tag Setup, Summary Output, LMDB List and MPPS tag definition
Start free trial →
300Software installation overview: methods 1/2/3, required media, site backup
Start free trial →
301Software work after replacing a RAID (RDD) disk
Start free trial →
302System Setup utility: model/tube/HFG selection at install and after hardware change
Start free trial →
303Reference: which site-information items the Backup Tool saves
Start free trial →
304Install the Essence-of-3D A license (pr.base / pr.3d) and verify
Start free trial →
305Start and stop DCA (Data Collection Analyzer) and its function set
Start free trial →
306Start and stop the Examination Scheduler setup tool
Start free trial →
307Install the system software from CD-ROM (boot, format, Windows 2000 setup)
Start free trial →
308Configure the TOSHIBA (Xlink) protocol network between consoles and peers
Start free trial →
309X-ray tube alignment workflow and OLP/warm-up prerequisites
Start free trial →
310Console-displayed error codes (0xb2xxxxxx)
Start free trial →
311Generator troubleshooting table (phenomena and countermeasures)
Start free trial →
312X-ray HV generator error codes (E00-E90) and troubleshooting map
Start free trial →
313Identify the defective inverter before replacement
Start free trial →
314Troubleshoot inverter temperature error and anode/cathode arc
Start free trial →
315Troubleshoot X-ray tube flow and thermal faults
Start free trial →
316X-ray tube oil cooler (heat exchanger) power-OFF function
Start free trial →
317Handle and replace the high-voltage cable (tube and SRU ends)
Start free trial →
318If (filament current) adjustment procedure
Start free trial →
319Check the rotor (starter) driver output
Start free trial →
320ESD / static-electricity precautions for service work
Start free trial →
321Replace the fuse and discharge the main capacitor safely
Start free trial →
322Service notices: floating section, power cable and gantry-rotation precautions
Start free trial →
323X-ray system safety precautions (signal words, DANGER/WARNING/CAUTION)
Start free trial →
324Remove and remount the SRU unit
Start free trial →
325Replace the inverter in the SRU generator
Start free trial →
326Entire X-ray system: configuration, specifications and operating principle
Start free trial →
327Overload protection (OLP) management functions
Start free trial →
328SRU (H/L) inverter and molded-transformer architecture
Start free trial →
329SRU generator composition and power supply unit (DRV PWB)
Start free trial →
330Tools and instruments for the X-ray system
Start free trial →
331Error-cause identification flowchart (block test to isolate SRU/HV cable)
Start free trial →
332Troubleshoot kV/mA output faults (Over mA, Under mA, HV overcurrent, Under kV)
Start free trial →
333Troubleshoot SRU status error and identify the faulty inverter block
Start free trial →
334X-ray tube system: configuration, specifications and cooling curves
Start free trial →
335X-ray tube malfunctions troubleshooting and malfunction-code reference
Start free trial →
336Checks and adjustments when replacing the X-ray tube
Start free trial →
337How If adjustment works (filament heating vs mA feedback)
Start free trial →
338Replace the XC PWB backup battery
Start free trial →
339Set up PWBs and adjust the kV waveform (VR3)
Start free trial →
340Troubleshoot XC operation, cable interlock and starter communication faults
Start free trial →
341XC Maintenance Program: block test, exposure/running test, debug monitor and screens
Start free trial →
342XC Maintenance Program: outline, connection and menu
Start free trial →
343XC Maintenance Program: Signal Show (kV/mA/If/HV waveforms)
Start free trial →
344XC PWB reference: switches, jumpers, LEDs, test points
Start free trial →
345XC Maintenance Program: log request and status information
Start free trial →
346XC maintenance program: R-status bit map, error-status bits, and Detail-screen parameter values
Start free trial →

346 sections · Full content available after sign in

Error Codes — decoded

760 codes

Each code below has a decoded reference page — meaning, severity and subsystem.

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

Service Procedures & Guides

197 guides

View all 197 guides →

All Aquilion 16 (TSX-101A) resources →Manuals, error codes & specs for this model

Frequently asked questions

Where can I access the Canon Medical Aquilion 16 (TSX-101A) service manual?

The full Aquilion 16 (TSX-101A) service manual is on FSELIB — the field-service engineering library for medical imaging. Sign in or start a 7-day free trial to open the complete manual: installation, calibration, troubleshooting, error codes and replacement procedures.

What does the Aquilion 16 (TSX-101A) service manual cover?

It covers 1000BASE switching HUB — PowerConnect 2708 (BSX74-1896), Navibox CNN-panel external cable map (CPU BOX and REC BOX), REC BOX connector pinouts (DAS, CONT FC-AL, SCONT1/2), Remove the host PC unit (PX74-07959 GR-1/GR-2), Remove the host PC unit (PX74-08766 GR-1/GR-2), Host PC unit specs and internals (PX74-07959 GR-1/GR-2) and more for the Canon Medical Aquilion 16 (TSX-101A) (CT Scanner).

Does the Aquilion 16 (TSX-101A) manual include error codes?

Yes — 760 decoded error codes for the Aquilion 16 (TSX-101A), each with its meaning, severity and the subsystem that reports it.

Is the Aquilion 16 (TSX-101A) service manual free to download?

Access is by subscription, with a 7-day free trial. FSELIB hosts authored, web-first service documentation (searchable procedures, diagrams and error-code references) — not a scraped PDF.

Related Manuals

💬 Forum Discussions about this Model