Toshiba / Canon Medical CT error codes
54 GTS (Gantry + Table System) status codes for the Activion16 (TSX-031A) and the Aquilion family — each with its meaning, severity, and the subsystem that reports it.
GTS controller (general) · 11
B1100000Error in GTSB11A0000The CT fluoroscopy circuit is abnormalB13A0000Error in GNS Main-taskB13B0000Error in GNS taskB1420000Error in Gantry/Couch movementB1500000Request rejected during Gantry/Couch movementB1810000Error in offset data AquisitionB1A00000Error in Gantry/Couch condition. Set them againB1D00000Aborted Gantry/Couch movement by [ABORT] buttonB1E00000Gantry/Couch in LOCAL modeB1F00000Error in GTS ( Time Out ). Retry, or contact your service representative
Patient couch / table · 22
B1270000Error in Table movementB1370000Table stopped in illegal positionB1380000Error in Couch movement(U/D)B1381000An error is detected in the chain for moving the bed verticallyB1382000An error is detected in a signal from the motor for moving the bed verticallyB1383000An error is detected in the motor for moving the bed verticallyB1384000The bed moved in the opposite directionB13C0000Error in Couch lateral movementB1520000An error was detected in controlling the vertical bed motionB1600000Table stopped with interlock mechanismB1650000Couch reached lowest positionB1660000Couch reached highest positionB1670000Table reached inner limitB1680000Table reached outer limitB16A0000Table reached rignt limit. [sic: 'rignt'=right no original]B16B0000Table reached left limitB1930000Couch vertical movement is abnormal. Contact your service representative immediatelyB1940000One of the couch vertical movement brake relays has malfunctionedB19C0000Couch lateral movement is abnormalB19C1000The couch lateral position sensor has malfunctionedB19C2000Couch option settings are abnormalB19C3000The couch lateral movement brake relay has malfunctioned
Gantry · 14
B1300000Error in Wedge movementB1320000Error in Slit movementB1330000Error in BeamTrimmer movementB1350000Error in Gantry TiltB1360000Error in Gantry RotationB1361000Error in Gantry RotationB13F0000Gantry is not powered ONB1400000Patient touched the GantryB1530000Cannot start CT scan due to PET gantry not being at the parking positionB1630000Tilt reached +30 degB1640000Tilt reached -30 degB1690000Cannot start a scan due to Ganty being positioned out of scan area. [sic: 'Ganty'=Gantry no original]B1F20000Error in Slit movementB1F30000Error in BeamTrimmer movement
Gantry cooling · 7
B1950000The DAS fan is abnormal. Although scanning is possibel,B1960000The circuit for monitoring the PWB cooling fan in the gantry is abnormalB1970000The PWB cooling fan in the gantry is abnormal. Although scanning is possible,B1980000The cooling fan used in data transfer system (1) is abnormalB1990000Settings are abnormal in data transfer system (2)B19A0000One of the cooling fans used in data transfer system (2) is abnormalB19B0000One of the gantry rotation control cooling fans is abnormal