Activion16 (TSX-031A) service procedures & guides

105 field-service procedure previews for the Canon Medical (Toshiba) Activion16 (TSX-031A) — what each procedure does, tools/parts and safety. The full step-by-step lives in the FSELIB service manual.

Console · 7

Couch/Table · 21

Adjust the couch descent (lowering) speed — solenoid throttle valves L21/L245 stepsAdjust the couch height display6 stepsAdjust the couch-top longitudinal belt tension6 stepsAdjust the couch-top supporting rollers (height, level, and sway)8 stepsChange the patient couch vertical stop positions2 stepsCheck the couch-top (horizontal) travel speed4 stepsCouch — routing of the internal cables at the linkage unit (work procedure)8 stepsEnable or disable couch-top sliding fine adjustment (KGTSM `adj`)5 stepsJack up the patient couch when it cannot move up from the DOWN limit (emergency)3 stepsManually lower the patient couch after a power/fuse failure (emergency)4 stepsPM: Inspect and maintain the couch clutch/brake assembly (dry type)5 stepsPartially disassemble the patient couch for narrow carrying-in routes (CBTB-018A only)10 stepsPatient couch control troubleshooting — KGTSM / KGTSP / slide servo amplifier faults76 stepsPatient couch troubleshooting — vertical lift, horizontal slide, rollers, and noise (by symptom)3 stepsReplace the couch horizontal (longitudinal) drive unit6 stepsReplace the patient couch hydraulic unit25 stepsReplace the patient couch's flexible cover7 stepsSet the couch autoslide movement range (KGTSM console)5 stepsSet the couch horizontal movement absolute-value control data (KGTSM console)5 stepsSet the couch vertical movement upward stop position (Auto-set mode, KGTSM console)5 stepsSet the couch-sliding zero-clear switch hold time (KGTSM `ctm`)5 steps

DAS · 9

Data Transmission · 9

Detector · 3

Detector/DAS · 1

Gantry · 32

Adjust the gantry positioning projectors (side, slant, and median)10 stepsAdjust the gantry rotation belt tension16 stepsAdjust the gantry rotation speed (servo amplifier, VR1)3 stepsAdjust the gantry servo-amplifier offset23 stepsAdjust the gantry tilt-stop angles (encoder calibration)5 stepsCheck the gantry rotation speed7 stepsCheck the gantry rotation speed voltage from the KGTSM PWB to the servo amplifier8 stepsCheck the safety circuit on the KGTSM PWB53 stepsClean the gantry exterior covers, Mylar ring, and mat switch3 stepsDiagnose gantry tilt faults — tilt disabled or noisy during tilt operation0 stepsGantry mechanical troubleshooting — tilt, rotation, slip ring, wedge, slit (by symptom)6 stepsManually tilt the gantry after a tilt-drive malfunction (emergency)4 stepsOpen or close the gantry front cover9 stepsOperate the KGTSM maintenance panel7 stepsPerform the checks after replacing the KGTSM PWB, servo amplifier, or servo motor0 stepsRelease the gantry rotation brake to turn the rotation section by hand (emergency)9 stepsRemove and mount the gantry rear-upper covers (left and right)3 stepsRemove and refit the Activion16 gantry top cover3 stepsRemove and refit the gantry Mylar ring6 stepsRemove and refit the gantry dome cover5 stepsRemove or mount the gantry side cover (right or left)3 stepsReplace a gantry laser-positioning projector lamp2 stepsReplace the gantry optical system (slit/wedge assembly)7 stepsReplace the gantry rotation motor8 stepsReplace the gantry tilt gas spring7 stepsService the gantry tilt drive: lubricate the tilt detection unit and replace the power cylinder24 stepsSet up and verify the gantry rotation servo amplifier29 stepsSlit section won't move, won't return, or is noisy — troubleshoot and repair3 stepsTroubleshoot da seção do anel coletor (slip ring) — escova gasta, ruído e descarga (Gantry)4 stepsTroubleshoot the Activion16 gantry rotation section0 stepsUse the KGTSM maintenance mode from a PC terminal8 stepsWedge section troubleshooting — filter won't operate, abnormal noise, or unstable wedge block0 steps

Options · 1

Power · 3

X-ray & HV · 4

X-ray Generator/HV · 10

X-ray Tube · 5