Activion16 (TSX-031A) service procedures & guides
105 field-service procedure previews for the Canon Medical (Toshiba) Activion16 (TSX-031A) — what each procedure does, tools/parts and safety. The full step-by-step lives in the FSELIB service manual.
Console · 7
Adjust the SS/ADI4 audio (gantry/console speaker and microphone VRs)4 stepsClean the console mouse4 stepsReplace disk array units (BSX74-2035E) — disk drive, power supply, and fan units10 stepsReplace disk drive, power supply, or fan units in the BSX74-1900E raw data disk array9 stepsReplace the host PC unit6 stepsRun the hwtest malfunction diagnosis program (Console)4 stepsRun the independent MHR PWB test from an RTM terminal (diagnostics)23 steps
Couch/Table · 21
Adjust the couch descent (lowering) speed — solenoid throttle valves L21/L245 stepsAdjust the couch height display6 stepsAdjust the couch-top longitudinal belt tension6 stepsAdjust the couch-top supporting rollers (height, level, and sway)8 stepsChange the patient couch vertical stop positions2 stepsCheck the couch-top (horizontal) travel speed4 stepsCouch — routing of the internal cables at the linkage unit (work procedure)8 stepsEnable or disable couch-top sliding fine adjustment (KGTSM `adj`)5 stepsJack up the patient couch when it cannot move up from the DOWN limit (emergency)3 stepsManually lower the patient couch after a power/fuse failure (emergency)4 stepsPM: Inspect and maintain the couch clutch/brake assembly (dry type)5 stepsPartially disassemble the patient couch for narrow carrying-in routes (CBTB-018A only)10 stepsPatient couch control troubleshooting — KGTSM / KGTSP / slide servo amplifier faults76 stepsPatient couch troubleshooting — vertical lift, horizontal slide, rollers, and noise (by symptom)3 stepsReplace the couch horizontal (longitudinal) drive unit6 stepsReplace the patient couch hydraulic unit25 stepsReplace the patient couch's flexible cover7 stepsSet the couch autoslide movement range (KGTSM console)5 stepsSet the couch horizontal movement absolute-value control data (KGTSM console)5 stepsSet the couch vertical movement upward stop position (Auto-set mode, KGTSM console)5 stepsSet the couch-sliding zero-clear switch hold time (KGTSM `ctm`)5 steps
DAS · 9
Check the DAS supply voltage (AJ-CONTROL / AJ-CONVERTER PWBs)3 stepsCheck the DAS supply voltage (Control-16 / Converter-16 PWBs)3 stepsDAS gain-dependent abnormality — reading the GAIN/odd-even-view pattern (§2.8.5)4 stepsDAS integrator-dependent abnormality — odd/even-view fault pattern (Integ-A / Integ-B)0 stepsDAS/detector troubleshooting — slice thickness-dependent (row-dependent) abnormality7 stepsData acquisition faults — cause × symptom matrix and 4 isolation flowcharts (DAS)8 stepsReplace the DAS PWB (Converter-16 / Control-16)7 stepsRun the DAS DCA test procedures (X-ray output, offset data, test pattern checks)19 stepsTroubleshoot Activion16 DAS data-acquisition image faults — cause matrix (AJ-CONTROL / AJ-CONVERTER)0 steps
Data Transmission · 9
Check gantry rotation and MUDAT data transfer after working on the MUDAT7 stepsCheck the MUDAT transmission-LED luminescence (ROT and SOT sides)7 stepsData transfer section error-identification test tools (DAS / Console / ROTSOT / SOTROT / OPCONTA / GCIFA)6 stepsDisassemble the MUDAT (rotation and stationary section PWBs)8 stepsGCIFA-D2 PWB troubleshooting flowchart (Data Transmission)0 stepsMalfunction of DAS data communication — cause investigation (streak/ring artifacts)26 stepsMalfunction of control system data communication — MUDAT ROTSOT/SOTROT fault tree (Data Transmission)14 stepsOutput GCIFA console test data and read the transmission-error display panel12 stepsSet the GCIFA tube-position switches for a Disable (non-rotation) scan4 steps
Detector · 3
Detector/DAS · 1
Gantry · 32
Adjust the gantry positioning projectors (side, slant, and median)10 stepsAdjust the gantry rotation belt tension16 stepsAdjust the gantry rotation speed (servo amplifier, VR1)3 stepsAdjust the gantry servo-amplifier offset23 stepsAdjust the gantry tilt-stop angles (encoder calibration)5 stepsCheck the gantry rotation speed7 stepsCheck the gantry rotation speed voltage from the KGTSM PWB to the servo amplifier8 stepsCheck the safety circuit on the KGTSM PWB53 stepsClean the gantry exterior covers, Mylar ring, and mat switch3 stepsDiagnose gantry tilt faults — tilt disabled or noisy during tilt operation0 stepsGantry mechanical troubleshooting — tilt, rotation, slip ring, wedge, slit (by symptom)6 stepsManually tilt the gantry after a tilt-drive malfunction (emergency)4 stepsOpen or close the gantry front cover9 stepsOperate the KGTSM maintenance panel7 stepsPerform the checks after replacing the KGTSM PWB, servo amplifier, or servo motor0 stepsRelease the gantry rotation brake to turn the rotation section by hand (emergency)9 stepsRemove and mount the gantry rear-upper covers (left and right)3 stepsRemove and refit the Activion16 gantry top cover3 stepsRemove and refit the gantry Mylar ring6 stepsRemove and refit the gantry dome cover5 stepsRemove or mount the gantry side cover (right or left)3 stepsReplace a gantry laser-positioning projector lamp2 stepsReplace the gantry optical system (slit/wedge assembly)7 stepsReplace the gantry rotation motor8 stepsReplace the gantry tilt gas spring7 stepsService the gantry tilt drive: lubricate the tilt detection unit and replace the power cylinder24 stepsSet up and verify the gantry rotation servo amplifier29 stepsSlit section won't move, won't return, or is noisy — troubleshoot and repair3 stepsTroubleshoot da seção do anel coletor (slip ring) — escova gasta, ruído e descarga (Gantry)4 stepsTroubleshoot the Activion16 gantry rotation section0 stepsUse the KGTSM maintenance mode from a PC terminal8 stepsWedge section troubleshooting — filter won't operate, abnormal noise, or unstable wedge block0 steps
Options · 1
Power · 3
X-ray & HV · 4
X-ray Generator/HV · 10
Adjust the If (filament) value remotely from the console31 stepsCheck the X-ray generator power-on and power-off sequence2 stepsCheck the X-ray tube current with the tube ammeter (MA-1201D)4 stepsCheck the X-ray tube voltage with the tube voltage meter (kV-201 bleeder)5 stepsHandle the high-voltage cable — removal, cleaning, and silicone-oil reassembly (CLAYMOUNT)15 stepsReplace the X-ray generator fuse2 stepsRetrieve and decode the XC PWB error log (direct RS-232C read + system-software XL30 console log)11 stepsRun a single-unit X-ray exposure from the console2 stepsTroubleshoot starter abnormalities (ST-7011,B / ST-7013) — E1-E8, inverter display codes, shaft lock release3 stepsTroubleshoot the Activion16 X-ray generator main circuit (9 fault flowcharts)0 steps
X-ray Tube · 5
Check the X-ray tube aging (warm-up and seasoning) schedule0 stepsCheck the X-ray tube getter aging (heat exchanger pushbutton)0 stepsClean the heat exchanger fan (annual PM)7 stepsConnect the replacement X-ray tube and run the operation check3 stepsX-ray tube troubleshooting — discharge, oil leakage, tube interlock, noise, and no tube current (by symptom)0 steps