GE MR — field troubleshooting
9,114 field-service issues · page 60 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- O2 Alarm Sensor is Defective.MR
- CWA Unable to Download or Reset The TPS MGD or ISE.MR · 2256923
- Tricks option fails to download...System not equipped with the appropriate hardware.MR
- Table Down Pedals are Not Working Due to Cradle Release Adjustment.MR
- Can the Optima 450w Magnet Curtain Option be used on the Discovery 750 Magnet.MR
- MCR Test Fails with The Signals Energy Level is Marginally Below the Expected Value Due to UTNS3.MR · 2247386, 18571
- Paused scans and image artifacts due to Power sagging from the normal 480 VAC down to as low as 0 VAC during the pulse sequence.MR · 2244573
- Images Are Not In The Browser Due To Database Out Of SyncMR
- Start Exam Button is disabled with MWL due to missing DICOM field.MR
- HP Computer Fails to Boot Linux Operating System.MR
- HP xw9300 fails to boot, beeps twice with red power LED, due to thermal overload.MR
- Unable to scan with Power Monitor Faults.MR · 2254791
- CWA Application software not completed boot with TPS not responding.MR · 2223878
- Unable to Scan Next Series due to Customer Popup Message "recon has not finished.MR · 2218731
- Gradient Artifact with No Errors or Gradient Pulsing Due to System Control Assembly.MR · 2240307
- 2254253 3T RF Amplifier PA Filament under Voltage (fault 38) due to blown fuse in MKS 3.0T RF Amplifier.MR · 2254253
- POWER MONITOR FAULTS Due to UPM RF Detector Board.MR · 2257270, 2248622
- Analogic RF Amplifier 1 Peak Power Faults Due to RF Amplifier 2 output low.MR · 2248825
- Dielectric Pad is leakingMR
- Short Circuit in 16 Channel Switch caused failure in SRI.MR · 2261176
- CWA SPT Process Aborted.MR
- CWA Unable to Scan with Error No. 2227915 The RDBM Read Header function returned the following error 6 The IT link is possibly disconnected or the IT Boards are not communicating.MR · 2249422, 2227915
- Nylon screw for cradle release actuator broke off carriage assembly when table was raised up.MR
- RF calibration not in specification.MR · 2248815, 2248816
- How to Temporarily Disable an Oxygen Monitor Alarm.MR
- Known Software issue with 15M4B coding error.MR
- Cradle Has No Movement Due To PHPS.MR · 2249110, 2224829
- Defective LCD monitor.MR
- Loss of Signal or Shading in Spine Images due to the Coil.MR · 2224709
- Part Number for the Gradient Cable Terminal Strip on Rear of the Ovation Magnet is Difficult to Find.MR
- Cradle home position not found due to S1 switch.MR · 2268834, 2268899
- Erbtec 52 faults due to a failed Amplifier.MR · 2225638
- Orthopedic XQ systemMR
- Applications boot fails due to corrupt software.MR · 2255485, 2223880
- OrthoMRI Will Not Scan with Gradient Errors.MR
- Intermittent Warnings of high Patient Comfort Temperature Readings due to Gradient Chiller.MR · 2248653
- CWA Fails TPS Reset when booting up to Applications or when Resetting TPS.MR · 2252245
- 2267502 Low signal during DTX2 calibration due to DTX2.MR · 2267502
- Will Not Scan With RF Errors.MR · 2225710
- CWA PDU is in Stop Mode.MR · 2248602
- RF Amplifier Interface Errors Due to SRFD2 RF Amp.MR · 2246047
- Buttons on Magnet Enclosure Control Panels do not work due to swapped cablesMR · 2254702
- Defective Patient Handling Power Supply Module (PHPS).MR
- Documentation Is Not Clear.MR
- Multicoil Bias Faults Due to Coil.MR · 2252293, 2224666
- Table will not advance Due to the carriage release actuator is not fully releasing the table top or cradle assembly.MR · 2224842
- Scan aborts with MDS link error due to SSM.MR · 2248670, 2248664
- ICN Fails to Configure Due to Sun ICN VRE.MR
- Cradle Will Move in Briefly then Stop Due to Table Plunger or cradle release Pin was preventing the table from advancingMR
- Technologist can't Hear the Patients Due to SCIM.MR
- TPS reset failed due to defective megaswitch.MR · 2267520, 2256925
- CWA Images Not Displayed In The Viewer Or The Browser.MR
- Annefact Star Artifact Root Cause.MR
- Images are in Autoview Window but not in Browser.MR · 2224340
- Intermittent Error 2252294 The Driver Module Has Detected an Invalid Configuration Source of Fault is Multi-Coil Board #2 Not Present, caused by Driver Module Firmware Bug.MR · 2218527, 2252294
- Unable to Scan with SGA Power Supply UnderVoltage Fault due to SGA-PS-LITE.MR · 2244862, 2244592
- 2244851 Current distortion fault due to HFD-S Lite Gradient Control Board.MR · 2244570, 2244851
- CWA Protocol PSD Download Fails.MR · 2218630, 2218501
- 2267863 The X axis XGA is reporting a I_Coil Wire Fault due to XGA amplifier.MR · 2267863, 2267778
- 181179 MR000107 PDS - HEC Alert - AVG Facility Supply Pressure Exceeds Specification.MR
- Unable to Scan with Message The IRF3 is not ready due to the install GUI and the mrconfig file did not match.MR · 2267431
- Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.MR · 2261733, 2268904
- CWA PDU in Stop Mode and TPS Download failure.MR · 2267798
- CWA PDU in Stop Mode and TPS Download failure.MR · 2252318, 51384
- CWA Loss of Center Frequency due to TCU powered off.MR · 2224708, 2224713
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.MR
- How do you go about performing the data base recovery on A Unix E-Scan Data Base?MR
- CWA PDU in Stop Mode and TPS Download failure.MR · 2267910, 3996792
- CWA Can Not Boot Application Software With VRE Errors.MR · 2277672, 1537357
- CWA Customer Needs to Know the Maximum Spatial Gradient of the Main Magnetic Field.MR
- MR000003 PDS - MC Bias Alert - High Percentage of Failures Detected Due to Failed Coil.MR000003 PDS - MC Bias Alert - High Percentage of Failures Detected During Coil Use.2423192 HEAD NECK UNIT.HDxT 1…MR
- Anterior Bridge Neck Coil to USAI CTL Does Not Stay Attached Due to Warn Parts to Latch.MR
- Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.MR · 2268904, 50171
- Defective Master Exciter2 board.MR · 2244720, 2247159
- Illegal characters in the dicom header.MR · 11057
- Intermittent CAN link errors due to Driver ModuleMR · 2252245
- Documented issue in HD16 customer release notes.MR
- Design of System.MR
- Cannot Boot Applications with Host Monitor Timeout Error.MR · 2249320, 1081934830
- Gradient undervoltage Faults Due to HFA Control Board.MR · 2244850, 2244570