POWER MONITOR FAULTS Due to UPM RF Detector Board.
Symptom
Scan Aborts with Error code 2257270 The Universal Power Monitor 1 (and/or 2) detected too much amplifier reflected power (Body Channel). See long description Scan aborts with error code 2257270 on both power monitors, see below. Error: 2257270 Host: E-OP-MR1 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: T1flair Coil: HDCTL TOP Scan: 53019/1 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel). Forward Power = 73. Reflected Power = 10.-> ------------------------------------------------------------------------ Wed Feb 11 12:36:08 2009 Error: 2257270 Host: E-OP-MR1 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: Gradient Echo Coil: 8HRBRAIN Scan: 53051/1 The Universal Power Monitor 2 detected too much amplifier reflected power (Body Channel). Forward Power = 1542. Reflected Power = 192.->
Error message
2257270 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel) See long description Error: 2257270 Host: cmr2 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: FSE-XL Coil: 8HRBRAIN Scan: 442/7 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel). Forward Power = 4929. Reflected Power = 620.-> 2248622 RF amplifier is not ready. See long description Error: 2248622 Host: HDx3T Process: NSP File: APS:aps_pass2 Line: 245 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: FSE-XL Coil: HDNV Array Scan: 4680/4 RF amplifier is not ready.
Applies to
- Models
- Signa
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 5250034 RF Detector 2 Board
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.