GE MR — field troubleshooting
9,114 field-service issues · page 59 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- MRIQ Noisy Images due to Coil.MRIQ Noisy images on the NV Array coil.SecondOpinion MRID 1.5T 8 channel NV array 2317115-2 wqr.Excite 11.1MR
- Images Reconstructed but not Listed in the Browser, Only Displayed in Auto viewer.MR · 2219864
- Unable to scan with Power Monitor Faults.MR
- MCQA Test Fails One or More Channels Due to Defective Coil.MR
- CWA No Video Signal Pop-up Message on Monitor.MR
- CWA Intermittent ROTMI Calculation Errors Due to too broad of a detection for radial prescriptions.MR · 2218725
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2223619
- 2267833 XGD reports no 420 V power due to XGD gradient power supply (XPS).MR · 2267833
- The system is unable to scan with any surface coil, get dynamic disable faults.MR · 2225539
- MRIQ Collapsed Image Bright White Line Down or Across Middle of The Image due to Gradient Power Supply.MR · 2244858, 2244593
- Planned Maintenance PM Schedules Window Pops Up On The Screen Due to Too Much Time Since Last Planned Maintenance.MR · 2218673
- 2244592 The GP is reporting a SGA Power Supply Over Voltage Fault Due to SGA Assembly.Replace the SGA Assembly wqr.Signa LX.2244593 The GP is reporting a SGA Power Supply Under Voltage Fault.9.1MR · 2244593
- 2254515 SRFD RF amplifier error with VSWR fault on the RF Amplifier.MR · 2254515
- PDU is in Stop Mode.MR · 2225935, 2248602
- Agfa Camera fails to print acceptable images following DV22.0 upgrade due to Camera Configuration.Unable to print to Agfa Printer after upgrading to DV22.0.Have Agfa Representative edit the Camera Con…MR · 3835009
- Center Frequency was offMR · 2247147, 21785575
- Auto and Manual Prescan Fails Due to the Scan Room Door Switch.MR · 2224666
- ACR uniformity under spec when using 8 channel head coil for phantom testing.MR
- Intermittent MGD - PCI, Raven, Serr, PERR, Harrier errors that stop scanning or TPS reset failing.MR · 2249409, 1579446
- Scan Stops With SRI error due to Defective SRI.MR · 2249107
- The Shoulder PA coil was defective.MR
- RF Amp Not Ready with Error Codes 2254347, 2254342 or 2254352 due to SRFD2 RF Amplifier.Will Not Scan With RF Errors.SecondOpinion SRFD2 1.5T Solid State RF Amplifier 2351573 UPDATED Dec 2 2010 wqr.Si…MR · 2254352, 2254347
- RF FET device is shorted Due to Analogic RF amplifier.MR · 2248821
- MRAPPS MRIQ Cine Phase contrast image is very noisy.MR
- MR750 Dock Motor Fails to Drive Table Up Due to Defective Dock Motor.MR
- Left Mouse Button Sticks and Right Button is Intermittent Work Around Due to Mouse.MR
- CWA Magnet Room Lights Are Out.MR
- CWA MIP images save as screen save images rather than as projections Due to Color Save Options Setting.MR
- OrthoMRI What are the dip switch settings for Artoscan 650 MB MOD drive Orthopedics Artoscan OrthoMRI Dip switch settings for Artoscan optical driveMR
- HP 9300 fails to boot to OS - Emitting Beeps due to a failure in the HP 9300.MR
- 2244851 Gradient Amplifier Y-Axis Current Distortion fault due to defective TRM.MR · 2244851, 2244577
- Unable to scan with Power Monitor Faults due to inappropriate coil selection for anatomy being imaged.MR · 2257270
- Coil Compatibility Matrix Doesn't Address HDi System Type.MR · 5440000
- MRIQ Shading in Images.MR · 2224713
- Cradle movement is Erratic over long distances due to servo drive.MR
- MRAPPS Series disappears after completing Edit Patient Data.MR
- MRAPPS How do I load the self-help online manual on the system.MR
- Body Forward Reverse Quadrature test fails due to RF Body coil.MR
- CWA Computer will not boot up to applications level.MR · 2249436
- Grainy Images Due to Shrapnel Metal in Area of Interest.MR · 2224589, 4062796
- 2222428 SRI LOCAL TEST FAILURE due to SRI.MR · 2222428
- SRI SCP Communication Error Due to SRI.MR · 2249110, 2249106
- Cradle Will Move in Briefly then Stop Due to Table Plunger or cradle release Pin was preventing the table from advancing.MR · 2224842
- ILINQ test message received from customer site.MR
- 8 Channel Coils are Not Recognized by Coil ID Due to Coil receptacle A not allowing coils to be plugged in properly. 8 Channel Coils are Not Recognized by coil id.MR · 2258107
- Table Longitudinal Drive Problems Due to Gear Reducer 40 to 1 Gear Box.MR · 2224842
- Unable to Send Images to the PACS due incorrect network configuration.MR · 11010
- CWA HP computer Fails To Power On due to GOC Breaker CB1 CB2 Off.MR
- Cannot scan with TR and dynamic disable fault Dynamic disable fault Due to SSM High Voltage Supply.MR · 2249158
- Head TR Driver faults Due to Loose Head Heliax Connection .MR · 2252305
- One or more SEVERE Failures Reported in the Latest SPT PM File.MR
- Collapsed Image and Gradient Link hammer Test Failures Due to the STIF or SRF TRF.MR · 2250082, 2244851
- 2252305 TR Driver Fault Detected Open Circuit Source of Fault is Body TR Due to Hybrid Splitter.MR · 2252293, 2252305
- Cycle Power To The System Cabinet And Reset TPS wqr.MR · 2257105, 2218624
- CWA Cannot Pull Work list from Broker Due to Corrupt WLSystem.cfg File.MR
- CWA How To Verify The Protocols Are On The MOD.MR
- CWR Software Crashes to Wallpaper and 6 Icons.MR · 200002352
- HP Computer will not boot applications software due to a failed network adapter - eth1.MR
- Need to copy an SPT protocol so I can run it outside of the SPT tool SVAT scriptMR
- Cannot scan with error 2254783 due to Scan Room Temperature sensor disconnected.MR · 2254783, 2268890
- CWA How to find the AE Title Port and IP Address.MR
- Collapsed Image Bright White Line Down or Across Middle of The Image Due to Tyme Board.MR · 2224713
- CWA Unable to scan with CAN Fiber optic Board not ready errors.MR · 2224666
- CWA The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or LoweredMR · 2268846
- Unable to Scan With Multi Coil Bias Faults.MR · 2252302
- Cannot scan with DCERD errors.MR · 2246027, 2265062
- Single click of the Left Mouse Button results in a Double Click Action Due to Mouse.MR
- 2269094 TDM overcurrent message due to failed RRX module.MR · 2269094
- Scan stops with gradient error 2244897.MR · 2244897
- Equipment Room Humidity Has Exceeded the Maximum Limits Due to Sites HVAC.MR · 2269038
- Multi Coil TR Driver Fault.MR · 2225551
- Scan Time Is Not Showing On The PCMR
- ERBTEC RF Amplifier Fault 89 Due To Blower Assembly Running Slow Or Stopped.MR · 2225668
- Questra Time is Off Due to Wrong Date or Time Set on Magnet Monitor 3.Magnet Monitor is displaying wrong date and time.Connect to MM3 Via Questra / InSIte 2 and run Remote Command to set Correct Date…MR
- Helium Level is in Alarm on the HFO SHeM.hfo alarm He 1 lower low.No Hold off set per HFO magnet SOP.MR
- Unable to scan with Power Monitor Faults due to HN Bulkhead Connector or Body Heliax Feed Through Connector.MR · 2225713
- Unable to Network to Any Destination Due to 8 Port Ethernet Switch Hub Inside GOC.MR · 11002
- CWA Browser does not list Exams.MR
- 2254278 3T RF Amplifier Enable Line fault 93 Due To Defective RF Amplifier.MR · 2254278
- Explanation of the Reconstruction Matrix and the Display Matrix for a given Acquisition Matrix wqr.MR