GE MR — field troubleshooting
9,114 field-service issues · page 61 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Application Software does not complete the boot process with TPS Download failure.MR
- Gradient Overload Due to 8645 Gradient Power Module.MR · 2238488
- Host Monitor Blank Due To Loose Monitor Power Cord At Back Of Monitor.MR
- Unable to View Serial Communications Displayed in APS, AGP, or SCP Terminal Windows, Garbled Due to Term Server.MR
- Warning Message The bore temperature sensor is disabled.MR · 2225096
- Cannot Advance Table to Scan Position Due To Loose Drive Shaft Screws.MR · 2224727
- Cradle is Making a Slapping Sound Due to Clutch Too Tight.MR
- Modifying the ipg_stage File to Emulate E-Stop Circuitry.MR · 2225081
- How To Find Installed Options Using sok_test.MR
- Part number of Ovation 4 MGD chassis FAN not found.MR
- Will Not Scan With RF Errors Due To XRFD RF Amp.MR · 2254606
- MCR2 fails B port due to bad B Bezel Harness Assembly.MR · 2247384, 18571
- LPCA is Configured in Guided Install Hardware for OvationHD.MR
- Unable select Unified phantom set for MCQA test due to SW bugMR
- CWA Unable to Download or Reset The TPS MGD or ISE.MR · 2247160, 51176
- Coil id not recognized intermittently due to Coil Cable.MR · 2273003
- Planned Maintenance PM Schedules Window Pops Up On The Screen Due to Too Much Time Since Last Planned Maintenance.MR · 2218671
- CWA ASSET Uncorrected Aliasing Artifacts Due to Off Center Patient Positioning in the Calibration Scan.MR · 2227991
- 2252301 Multicoil Bias Fault Detected Open Circuit Due to Driver Module.MR · 2252301
- Tiny Plastic Balls Are on the Patient Transport Due to Broken Cradle Lateral Bearing.MR
- EPI and DWEPI Image Distortion Due to Shim.MR
- CWA Honeywell Gas Monitor Is Alarming.MR
- Will Not Scan with Gradient Errors due to the GP3 Gradient Processor.MR · 2244848, 2244574
- Table Longitudinal Drive Problems Due to Gear Reducer 40 to 1 Gear Box.Table Needs a Push Moving in and Cradle Unlatches.Signa HDxT.2224727 Unable to start prescan!MR · 2224727
- Unable to Scan With Multi Coil Bias Faults due to Driver Module.MR · 2252293, 2252301
- The Axial Alignment Light gets loose and tips in or out.Alignment light has two lines.Adjust the position of the Axial Alignment Light wqr.Excite HD 12.0MR
- Table Will Not Dock or Undock Due to The Dock Hook was Loose.Table Will Not Dock.Adjust the Dock Hook Tension wqr.Optima MR450W 21.0MR
- XGA reporting a GD power failure due to XGA.MR · 2267859
- Site Air Conditioning failure. 3T RF Amplifier Fails with PA Air Too Hot Fault 47.MR · 2238930
- LCD Monitor Fails ACR Test Due to Monitor Brightness.LCD Monitor Fails ACR Test.Adjust monitor brightness,wqr.Signa LX 9.1MR
- Broken Side Latch on Medical Advances Foot/Knee Coil.MR
- Overtemp errors due to low equipment room temperature.MR · 2269044
- Fiber Optic Link Errors Due to IRF I/O Board.MR · 2254012, 2247160
- CWA Lost Exam in Browser During Edit Patient Data with Edit Patient Data has Detected an Internal Error.MR
- CWA Fails TPS Reset when booting up to Applications or when Resetting TPS.MR · 2226595
- ICN diags fails with Error 2277676 Disk Health Diagnostic failed on ICN Due to ICN.MR · 2277676, 1525468
- Customer is unable to scan due to intermittent PDU PS1 48 V power supply failures.Unable to scan.Replace PS1 48 V supply in PDU wqr.Discovery MR750.2267910 The Power Cabinet AUX board is reporting a 4…MR · 2267910, 3996792
- Center Frequency was off.Auto prescan Fails with Signal Too Small message on all coils.Correct Center Frequency wqr.Discovery MR750.2224580 Auto Prescan failed.MR · 2224580
- Cannot scan with Error 2274021 Coil Fault - Short Circuit A multicoil bias fault was detected due to coil.MR · 2274021
- MRIQ Intermittent White Pixel and Corduroy Artifacts Due to USAI 8 Channel Body Coil.MR
- How to Login and View ICN VRE Error Logs.How to Login and View ICN VRE Error Logs.wqr.3.0T Signa HDxT 15.0MR
- cannot scan thick FIESTA slabs back to back...error indicates insufficient memoryMR · 2218527
- 2250079 % Axis Gradient Data Overrange Occurred due to HFA-S Gradient Amplifier.MR · 2250079, 51000
- Unable to archive Due to svst File.MR · 10192
- Clarify. Cross Reference Lines Missing From Screen Saved ImageMR
- Clarify #018055 cannot scan due to fermi filter errors.MR · 2224666, 2228718
- The operator's knee hit the scim cable connection beneath the console tabletop.MR · 2224666, 2218537
- Applications fails to boot due to SCP board.MR · 2249418, 2249305
- Burning Smell in Magnet Room Due to patient blower.MR
- Auto prescan fails with signal too small on head coil due to Poor Seating of Quad Head Coil Cables and/or Quick Disconnect Box.MR · 2224666
- How do I disable proprietary software on an MM3 remotely.From IDM Application suite (Questra), select "Run Command", then pick "Disable Proprietary Mode" and slect run,wqr.Magnet Monitor 3 1.56MR
- RF amplifier not ready due to RF amp.MR · 2254230, 14528
- There are greater output tolerances between two types of power supplies in the Chronus chassis.MR · 2267925
- CWA Mouse Stops Working During A Scan.MR · 200002352
- Does error 2277672 - WARNINGMR · 2277672, 1537357
- 3T RF Amplifier Error - Prescan Fails with No Signal.MR · 2248763, 2254261
- cannot login and all buttons lit up on keyboardMR · 2241085, 2241081
- Defective HFA - High Fidelity Amplifier.Will Not Scan with Gradient Errors.SecondOpinion HFA ASSEMBLY WITH FRU PACKAGING, 2393906-4 wqr.Signa HDxT.2244570 The gradient amplifier failed to go to Ready…MR · 2244570, 2244897
- Octane computer cant see mouse or keyboardMR
- Defective XPS power supply 5148804-2 causing Error 2267902.Will Not Scan with Gradient Errors.Replace XGD Power Supply XPS 5148804-2,wqr.Optima MR450W 21.0.2267899 The %b XPS-SB is reporting an input…MR · 2267902, 2267899
- Unable to Scan with Multi Coil TR Driver Faults.MR · 2218537, 2225552
- Short Circuit in 16 Channel Switch caused failure in SRI.CoilID Not Working for Any Coil CoilID Light Never Illuminates.Replace 16 Channel Switch and SRI AFTER checking this Long Description wqr.22611…MR · 2261176, 2261180
- Cannot Boot Applications Due to Image Space Query Failed.MR
- How to Identify Starmap Acquisition Option M3340AE on Scanner.How to Identify Starmap Acquisition Option M3340AE on Scanner,wqr.Signa HDxT 15.0MR
- EPT (Echo Planar Test) B0 Image test failed.MR
- HIS RIS Worklist Comes Up Empty Due to Required Return Tags Configuration.MR
- Sage analysis application button is missing from browser.MR
- RF calibration not in specification.MR · 2224589, 4062796
- PM EPIWP is reusing the TG value found during the previous run of LVshim.MR · 2254782
- Power Surge or Drop.MR · 2218537
- Concern about pop-up Message Application Disk Space Low, but System Scanning ok.MR · 2218678
- Image reconstruction is very slow.MR · 2224340
- Will not Scan with 2254207 SRFD2 RF Amplifier Device Fault 44 RF FET device is shorted Due to the SRFD2 Amplifier.MR · 2254207
- 2254265 3T RF Amplifier PA Bias Current fault 61 due to RF amp.MR · 2224666, 2254265
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2218661, 2249418
- Defective HFA - High Fidelity Amplifier.MR · 2244847, 2244870
- Need Tools to Repair Times Microwave Heliax Cable.MR
- Date on the Host is Set Wrong.MR
- Table will not stop raising due to loose screws on dock motor actuator microswitch (DOCK MOTOR ON SWITCH) inside the dock assembly.MR
- CWA Accidental Push of E-stop Button.MR · 2267825