GE Healthcare · MRSignaExcite224867022486642248674
Scan aborts with MDS link error due to SSM.
Symptom
Scan Aborts with MDS Link Error
Error message
2248670 MDS link failure. An MDS device failed to respond to SCP on a second try. Mon Feb 2 13:27:26 2004 2248670 1 MR-OC0 NSP SCP:MdsLinkHWO 1407 MDS link failure. An MDS device failed to respond to SCP on a second try. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. MDS timer: 0x0025 Transmitted header: 0x10 Gradient Transmitted opcode: 0x02 EN 351 2248664 - MDS link failure. An MDS device failed to respond to SCP Mon Feb 2 13:27:26 2004 2248664 1 MR-OC0 NSP SCP:MdsLinkHWO 1395 MDS link failure. An MDS device failed to respond to SCP. If the link is broken, a separate error message will be logged. If not, a spurious error occurred. MDS timer: 0x0025 Transmitted header: 0x10 Gradient Transmitted opcode: 0x02 EN 335 2248674 MDS link failure The MDS fiber optic link appears to be broken between the RF and System cabinets. Mon Feb 2 13:27:28 2004 2248674 1 MR-OC0 NSP SCP:../MdsLinkHWO.cpp 983 MDS link failure. The MDS fiber optic link appears to be broken between the RF and System cabinets. Check RF cabinet power, fiber optic connections and signal level of the fiber optic link between the cabinets. Run MDS fiber optic link diagnos
Applies to
- Models
- Signa, Excite
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- SecondOpinion System Support Module 2160200-43 See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH See comments in resolution concept for second opinion requirements before ordering this part. FE replaced SSM which is now a FRU Part #: 2160200-43 Part Type: GP REPAIRABLES Part Weight: 48.50 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: ERBTEC #550020 SYSTEM SUPPORT MODULE FRU: Yes Status: Orderable ICV/Transfer Price: 5684.00 USD /Each List Price: 36215.22 USD /EACH
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.