GE X-ray Vascular — field troubleshooting
1,562 field-service issues · page 10 of 20
Symptom, error message and equipment context for each GE X-ray Vascular issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Table brakes not holding, error on monitor about patient fall.X-ray Vascular
- ID158943, Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.X-ray Vascular · 600205, 600200
- Lateral Plane will not move into iso center following first boot in the morningX-ray Vascular · 1050607
- Innova system will not boot into applications, it asking for a password.X-ray Vascular
- Light on control box (TSSC) that displays magnification is not working.X-ray Vascular
- IQ+ or PRO table, Table Operation Degraded; Call service is displayed on the monitor.X-ray Vascular · 1070334, 1070384
- Innova, 3D Spin stopped in mid acquisition.X-ray Vascular · 1050132
- The Table top locks do not engage, the table is floating.X-ray Vascular · 50118
- ID159088 Unable to move the Omega Table.X-ray Vascular · 1050187
- Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.X-ray Vascular · 30021, 20056
- 1050015 C-arc AXIS POT ENCODER MISMATCHX-ray Vascular · 1050015
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitorX-ray Vascular · 3602062, 3602051
- No Acquisition exposure, fluoro or recordX-ray Vascular · 200013
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.X-ray Vascular · 2810010, 1610026
- Tube Collision not cleared.X-ray Vascular · 1050305
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.X-ray Vascular · 810006, 1610006
- 159886 INX100, !Unintended Motion Risk.X-ray Vascular · 1050211
- IQ+ or PRO table, Table Operation Degraded; Call service is displayed on the monitor.X-ray Vascular · 1070130, 5161556
- Unintended Motion risk.X-ray Vascular · 1050090, 1050233
- How to tell if your detector is PKI or CRDX-ray Vascular · 2270465, 2299934
- Omega, noise coming from the bottom of the table or the table base. sounds like a grinding noise.X-ray Vascular
- 160091 Innova, Image Quality DegradedX-ray Vascular · 3800315
- Innova; Table and Gantry will not move by any control.X-ray Vascular · 50127
- 160096 Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.X-ray Vascular · 30021, 20056
- DL system does not boot at power upX-ray Vascular
- IN IQ, Cannot move the table or gantry with any control.X-ray Vascular · 1070370, 5184723
- tabletop panning is not smoothX-ray Vascular
- Innova; Table and Gantry will not move by any control.X-ray Vascular · 60008
- ADV, No fluoro or record image on monitor with x-ray message on.X-ray Vascular
- Boot failure- Reset system; If problem persists call Service is displayed on the Innova MonitorX-ray Vascular · 1200114, 1300114
- Grid unlocked error with no gantry movementX-ray Vascular · 1050169, 50013
- Positioner error.X-ray Vascular · 1050274
- INX1X1, How to understand an ALARM message preceded by an Index number Acquisition monitor is display .X-ray Vascular · 1050211
- 161026 The Advantx console displays 600E Recommended X–ray tube Preventive Maintenance.X-ray Vascular · 70002
- How to find, review and download most appropriate documentation, ASM, or technical publications for vascular products in Myworkshop.X-ray Vascular · 5192425
- Healthpage does not collect errorlog nor eventlogX-ray Vascular
- Detector Collision Error; Press Detector front plate to re-initialize is displayed on the Innova MonitorX-ray Vascular · 1050166
- 161291 C-arc not movingX-ray Vascular · 50108
- The Gantry Pivot position does not match the In Room Display.X-ray Vascular · 1050015
- 161530 Innova, When performing a worklist Query the DL status bar indicates "Worklist Query Failed"X-ray Vascular
- All lamps, back lights on the TSUI (TSSC or Smart Handle / Box) are flashingX-ray Vascular
- 161719 Gantry Limit Switch Engaged, Please Call Service; is displayed on the Image MonitorX-ray Vascular · 1050261
- Fluoro image very bright (saturated) in automatic modeX-ray Vascular
- Patient Fall risk.X-ray Vascular · 1050277, 1050252
- Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.X-ray Vascular · 3602024
- 161757 Detector lift won't move up or down.X-ray Vascular · 50108
- ID161776 Innova; Table and Gantry will not move by any control.X-ray Vascular · 1050263, 1050262
- Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor.X-ray Vascular · 3602027, 3702027
- The In Room Browser does not function from The Innova Central Touch ScreenX-ray Vascular · 2810001
- LCA gantry does not move, LCA display is Blank, MVME in a continuous resetX-ray Vascular
- Unable to move the Lift using the Smart HandleX-ray Vascular
- 162034 INX100, !Unintended Motion Risk.X-ray Vascular · 1050147, 1070323
- Xray not Available - Reset System; If Problem Persists Call Service is displayed on the Image Monitor.X-ray Vascular · 600105, 1000025
- "Disk full - Free Disk Space" message is displayed on In Room Monitor DisplayX-ray Vascular · 2800041
- Unable to start Medical Application package on DLX-ray Vascular · 1050188, 810012
- 162678 Gantry Limit Switch Engaged, Please Call Service; is displayed on the Image MonitorX-ray Vascular · 1050263, 50263
- 162837 Gantry C-arc motion is jerky and it is making strange noisesX-ray Vascular · 50110
- "Emergency stop occurred.X-ray Vascular · 1050179
- System can't boot up with error 4F2E Reports on Advantx Console; message "Xray not available; Reset system to recover; Xray; Call Service" display on consoleX-ray Vascular · 1200011
- Vertical white lines are seen in the image during digital fluoro.X-ray Vascular
- DLX image transfer to AW failsX-ray Vascular · 450043
- During fluoro 42E9 error displays on advantx screen and beeps xray not inhibitedX-ray Vascular · 30053, 212011882
- Fluoro Taper calibration cannot be submitted in the SUIFX-ray Vascular
- Innova System boot failureX-ray Vascular · 3602010, 3702010
- Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.X-ray Vascular · 1200109
- 163869 INX1X1; 3KVA UPS will not power on, PDB is on, Innova will not turn on.X-ray Vascular
- Innova, Customer can not delete patient, no error displayedX-ray Vascular
- Config network Firewall Insite server IP addressX-ray Vascular
- Filament drive error.X-ray Vascular
- Firewall configuration failure in SUIFX-ray Vascular
- 164906 50108 Power Voltage failure error is logged intermittently in the SUIF or detected by Healthpage.X-ray Vascular · 50108
- Positioner Error Reset System is displayed on the in room monitor.X-ray Vascular · 1050274, 1050042
- DL lockup during use.X-ray Vascular · 1600017
- 165093 Innova; Table and Gantry will not move by any control.X-ray Vascular · 1050167, 1050607
- 165096 Wrong time or date on DLX imagesX-ray Vascular
- The Gantry Pivot Axis will not Drive RAO / LAOX-ray Vascular · 1050095, 1050002
- 165167 Advantx displays reset on console and xray is inhibitedX-ray Vascular · 30050, 30049
- 165316 Cannot Start a Bolus Chase Run.X-ray Vascular · 2210001, 2200010
- 3D calculation process in SUIF fails before normal completionX-ray Vascular · 1200007, 810007
- Image Quality Degraded; Tube inspection requested displayed during fluoro or Record, may hear loud popping noise coming from tubeX-ray Vascular · 3602085