ID158943, Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monito…
ID158943, Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
600205 and 600200 collimator errors are in the log 600205 Collimator Rectangular blades recoverable error; continue AR XRBeamForm Rect. Blades Component(s)_Collimator 0 0 Collimator motor stepping longitudinal XRPAtlasLogger.cpp 156 600200 Collimator rectangular blades autocalibration failed IH XRBeamForm Rect. Blades Component(s)_Collimator 0 0 Error or timeout on collimator rectangular blades recalibration after several retries XRPAtlasLogger.cpp 156 600205 and 600200 collimator errors are in the log 600205 Collimator Rectangular blades recoverable error; continue AR XRBeamForm Rect. Blades Component(s)_Collimator 0 0 Collimator motor stepping longitudinal XRPAtlasLogger.cpp 156 600200 Collimator rectangular blades autocalibration failed IH XRBeamForm Rect. Blades Component(s)_Collimator 0 0 Error or timeout on collimator rectangular blades recalibration after several retries XRPAtlasLogger.cpp 156 600205 Collimator Rectangular blades recoverable error; XRBeamForm Rect. Blades Component(s) Collimator motor stepping longitudinal 600205 Collimator Rectangular blades recoverable error; continue AR XRBeamForm Rect. Blades Component(s) Collimator 1 1 Collimator motor stepping longitu
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Innova Collimator Innova collimator Innova collimator
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.