GE X-ray Vascular — field troubleshooting
1,562 field-service issues · page 11 of 20
Symptom, error message and equipment context for each GE X-ray Vascular issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- innova 2000 system turned off by itself.X-ray Vascular
- Lift failure, dose is minimized, call service.X-ray Vascular · 1050048
- TSUI are not working:Innova 2000:TSSC Power TSGX-ray Vascular
- There is a line artifact on the monitor during fluoro and Record.X-ray Vascular
- ADX, advantx no gantry operation.X-ray Vascular
- The DL Monitor is displaying the message Xray not available; Collimator power failure Call Service.X-ray Vascular · 600101
- INX100, Acquisition constantly replays or plays fast after acquisitionX-ray Vascular
- 166213 TSSC Failure.X-ray Vascular · 1070385, 5184194
- Detector collision not cleared, Please clear collision or call serviceX-ray Vascular · 1050168
- No gantry motion is reported by the customer.X-ray Vascular · 50108
- Need to change patient demographics on an Innova system.X-ray Vascular
- The image monitor displays the error messageX-ray Vascular · 1050610
- Xray Abort Reposition Collimator Blades is dispayed on the Advantx console and Patient Dose Mismatch.X-ray Vascular · 600104, 1000014
- Database inconsistency failure; Call service for repair.X-ray Vascular · 2800148
- Gantry motion is reduced to half speedX-ray Vascular · 1050155, 100000155
- No communication between SUN workstation and VDP at DLX application start up.X-ray Vascular
- Acquisition (Fluoro or Record) does not startX-ray Vascular
- Table brakes release via TSSC long/lat lock button but do not release via SH/SB table enableX-ray Vascular
- Connectivity or HealthPage ScheduleX-ray Vascular
- Lock-Unlock function not working for gantry motionX-ray Vascular
- System failure.X-ray Vascular · 2810023, 2810052
- Xray unavailable message on live display with fluoro and record modes with footswitch depressed.X-ray Vascular · 3602031
- Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.:Innova 2000:30048 POWER UNITX-ray Vascular · 30048
- Horizontal artifact displayed on first two frames in any acquisition modeX-ray Vascular
- 168180 Innova, When performing a worklist Query the DL status bar indicates "Worklist Query Failed"X-ray Vascular · 00400003
- DLX application crash on Store PhotoX-ray Vascular
- Biplane DSA acquisition does not startX-ray Vascular
- System software configuration not updated in PDSX-ray Vascular
- ADX console not booting up completely.X-ray Vascular · 4000048, 4000054
- 169496 Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.X-ray Vascular · 3602086, 3702086
- Detector collision not cleared, Please clear collision or call serviceX-ray Vascular
- Collision risk.X-ray Vascular · 1050709
- 169761 Omega table will not drive up when table top is loaded.X-ray Vascular
- Unable to start DLX application with "dlx" as user name - a password is required.X-ray Vascular
- 3D calculation process in SUIF fails before normal completionX-ray Vascular
- The Digital Leader DL displays Hardware Error during boot of the systemX-ray Vascular
- Digital Leader DL Hangs during OS BootX-ray Vascular
- Cannot start Bolus run - Start / End positions are lostX-ray Vascular · 4210009
- DL and Image monitors are not powered on, blank.X-ray Vascular
- Frontal & Lateral gantries are locked after system boot.X-ray Vascular · 1050743, 1150743
- INX100, !Unintended Motion Risk.X-ray Vascular · 1050066
- ID171507 Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.X-ray Vascular · 200013
- Tube Chiller low fluid alarm, The Chiller is making a beeping sound and the bowl indicator is lit.X-ray Vascular · 3602084
- Xray unavailable message on live display with fluoro and record modes with footswitch depressed.X-ray Vascular · 3602031
- Detector collision not cleared, Please clear collision or call serviceX-ray Vascular · 1050178
- Innova X100 MonoplaneX-ray Vascular · 4800008
- In DLservice, cannot copy RTAC backup files to USB device.X-ray Vascular
- The Omega table top locks do not release and the customer is unable to move the table top.X-ray Vascular · 1050082
- No Acquisition exposure, fluoro or record:Innova 2000:30050 POWER UNITX-ray Vascular · 30050
- Communication FailureX-ray Vascular · 1050184
- Replace the Digital Leader (DL) system monitor.X-ray Vascular
- Detector lift won't move up or down.X-ray Vascular · 1050048
- The Innova Central ITU fails to boot up and display the user templates.X-ray Vascular
- Live Image is blurry, Looks like a fisheyeX-ray Vascular
- Bottom half of the Image monitor display is blankX-ray Vascular
- Innova X100 MonoplaneX-ray Vascular · 1000025
- 20KVA UPS is making a loud clicking noise every 30 secondsX-ray Vascular · 410012, 410013
- DLX will not boot. "Unrecoverable Hardware Error" is displayed.X-ray Vascular · 100003
- In-room TSSC or Smartbox not detected Call ServiceX-ray Vascular · 1070655, 1070200
- INX100, Lost All Gantry axis's drive or NO movementsX-ray Vascular
- Xray unavailable message on live display with fluoro and record modes with footswitch depressed.X-ray Vascular · 3602032, 20005
- Gantry moving at half speed with no errors.X-ray Vascular · 1050613
- An asynchronous error has been detected by the IP, 2810052X-ray Vascular · 2810052
- Failing IQST/QAP Dark Smudge/Spot ArtifactX-ray Vascular
- Gantry moving slow due to DETECTOR collision sensor errors.X-ray Vascular · 1050168
- Isodensity artifacts visible on fluoro/record images during acquisition and during reviewX-ray Vascular
- "This sequence cannot be reviewed" displayed on live In Room monitor.X-ray Vascular · 2800007
- No table longitudinal motion:Innova 4100:IQ+ or PRO TableX-ray Vascular · 1070210
- Innova, The worklist query returns some patients, but not all the patients that should be there.X-ray Vascular · 4001340, 00080104
- INJECTION FAILED X-RAY ABORTED; during a run or run-off after the mask image.X-ray Vascular · 2400017, 1610034
- The Advantx Console is Blank on boot of the system.X-ray Vascular
- Lateral tube will not allow more than two or three degree cranial angle change without stopping.X-ray Vascular · 1050102, 1050512
- The longitudinal table top movement starts and stops while driving.X-ray Vascular · 1050182
- After Customer performed EPO the 20KVA UPS would not turn on properly and provide power the system.X-ray Vascular
- Table rotation is binding (has seized up) at the detent position.X-ray Vascular
- Backup Power not available.X-ray Vascular · 410016
- Positioner boot failureX-ray Vascular
- Ilinq pull down list is incorrect.X-ray Vascular
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitorX-ray Vascular · 3602083, 3702083
- 174289 Detector lift won't move up or down.X-ray Vascular · 50111