GE Healthcare · X-ray VascularInnova1050261
161719 Gantry Limit Switch Engaged, Please Call Service; is displayed on the Image Monitor
Symptom
Gantry Limit Switch Engaged, Please Call Service; is displayed on the Image Monitor
Error message
INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. INX100: 1050261 FRT PIVOT AXIS SWITCH ENGAGED (PRD BC) error code 1050261 FRT PIVOT AXIS SWITCH ENGAGED WR GantryAxis No Motion PIVOT_Limit_Switch 1 0 - Limit switch 2 problem (prd: BC) Z:/heroic/prd_task.c 638 MCB prd code BCH is displayed on the MCB is displayed in the error log. The Pivot MCB has a PRD code of BC displayed on it. 1050261: Front: FRT PIVOT AXIS SWITCH ENGAGED; Debug Text: - Extra course switch engaged or 24V failure (4AB6)
Applies to
- Models
- Innova
- Product
- X Innova 4100 X Do not use---------4100 systems 4100 systems
- Software
- $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 Date 01-01-2010 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 SP4 SYSTEM RELEASE UIS 4.52.1 DL GHOST 22.2.3 DL DL_Unity_4.19.14 GITANE V7.47 ITU OS: 2.2.4.6 RAFI: 1.11 GE: 1.3.3 Calypso CLY.PLATFORM 4.52.XX IDC 5.39.XX GITANE V9 FW1.5 POS CPU RR POS LBY 1.4.4U_23 PST 1.9.D PIB SW V3.6 FPGA V4.3 (with every type of interco lift) MCB DSP 34F / FPGA317 STEPPER BOARD IS6.31L JEDI P6.36BF1 AW AW4.4_04 or AW4.3_05.04 or AW4.2_07 3DXR 1.0.5.XX VOLUME VIEWER 6.5.0 or 6.7.0 or 6.8.3 or 7.4.71
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.