GE Healthcare · X-ray VascularInnova1050187
ID159088 Unable to move the Omega Table.
Symptom
Unable to move the Omega Table. The Table top locks do not release and up/down motion does not work. The customer is unable to move the Omega Table. The Table top locks do not release and up/down motion does not work. The table is not functioning. The customer is unable to move the Omega Table. The Table top locks do not release and up/down motion does not work. errors 1050278
Error message
1050187 Table Rotation encoder Comm lost Error 1050187 Table Rotation encoder communication lost. See long description for further details. Error 1050187 Table Rotation encoder communication lost. In the errlog, we get the following error: Positioner CPU does not get anymore table rotation value. As a side effect, you may get following error after a record acquisition: This means that a data from positioner was either missing or out of range.
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC) Omega IV Cardiac table Omega IV Cardiac table Omega IV cardiac table
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.