GE Healthcare · X-ray VascularInnova10500951050002
The Gantry Pivot Axis will not Drive RAO / LAO
Symptom
The Gantry Pivot Axis will not Drive RAO / LAO . The Customer Complains when driving the Pivot Axis it will not complete the movment. The Gantry Pivot Axis will not Drive RAO / LAO. The Customer Complains when driving the Pivot Axis it will not complete the movment.
Error message
INX100: 1050095 Pivot AXIS CONTROL LOOP GantryAxis Intermittent Motion stop Pivot AXIS CONTROL LOOP servoloopsCheckPosition 1050095 Pivot AXIS CONTROL LOOP DO GantryAxis Intermittent Motion stop Pivot AXIS CONTROL LOOP 0 0 - servoloopsCheckPosition Z:/heroic/motion control task.c 4540 1050002 DO GantryAxis BUDDY Larm AXIS ENABLE disable from buddy 1050002 DO BUDDY Larm AXIS ENABLE GantryAxis null BUDDY_Larm_AXIS_ENABLE disableFromBuddyN This error is caused by the Buddy of the LARM (Pivot MCB) disabling the enable of the LARM, to prevent Gantry motion during a failure. The disable is issued when the Buddy AMP detects a failure on the LARM or the Buddy (Pivot) has failed 1050002 DO BUDDY Larm AXIS ENABLE GantryAxis null BUDDY_Larm_AXIS_ENABLE disableFromBuddyN This error is caused by the Buddy of the LARM (Pivot MCB) disabling the enable of the LARM, to prevent Gantry motion during a failure. The disable is issued when the Buddy AMP detects a failure on the LARM or the Buddy (Pivot) has failed.
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.