GE Healthcare · X-ray VascularInnova105027410500421050103105001610500501000014
Positioner Error Reset System is displayed on the in room monitor.
Symptom
Positioner Error Reset System is displayed on the in room monitor.
Error message
INX100 error 1050274 PIB 180V OVERTEMP: Component(s)_Positioner_Martek; - Martek: 180V module overtemperature Re-occuring positoner axis power errors 1050042 1050103 1050016 1050050 1050042 Larm AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050103 Pivot AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050016 Carc AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050050Lift AXIS MCB INTERNAL Debug: - Problem on internal Emergency brake circuit (prd: B8) Re-occuring positoner axis power errors 1050042 1050103 1050016 1050050 1050042 Larm AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050103 Pivot AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050016 Carc AXIS POWER Debug: - Power input from K3 problem (prd: BD) 1050050 Lift AXIS MCB INTERNAL Debug: - Problem on internal Emergency brake circuit (prd: B8) 1050050 Lift AXIS MCB INTERNAL DO GantryAxis Speed Degraded Lift AXIS MCB INTERNAL 0 0 - Problem on internal Emergency brake circuit (prd: B8) Z:/heroic/prd task.c 638 1050050 Lift AXIS MCB INTERNAL DO GantryAxis Speed Degraded Lift AXIS MCB INTERNAL 1 0 - H Bridge or Overcurrent detection circuit problem (prd: C3) Z:/heroic/pr
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- 180V Martek power supply 180V Martek power supply replacement. Part number = 5168282 180V Martek power supply replacement. Part number = 5168282
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.