160096 Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
30021: Vamp POWER UNIT : EXCESSIVE CURRENT ON INV A 30021: POWER UNIT : EXCESSIVE CURRENT ON INV A is logged on exposure. Followed by 20056 ECM : POWER UNIT IN RESET STATE DUE TO ERROR, and 20039 ECM : POWER UNIT IN RESET STATE - PREP/EXPOSE SWITCH IGNORED 30021: POWER UNIT : EXCESSIVE CURRENT ON INV A: AR: HWStatus=0016 User=0000 0000 42C6 Red LED SURC on the small filament board is lit after boot up. 30021 is followed by 20056 ECM: Power Unit in Reset State Due to Error: AR: HWStatus=0001 User=0000 0000 4260
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $ Innova2000, HER_M6_12.31, M6 release to be used with DL6/RTAC6 hardware Innova2000 M6 release to be used with DL6/RTAC6 hardware on Innova 2000. Heroic M6 release to be used with DL6/RTAC6 hardware on Innova 2000.
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.