Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.

Symptom

Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76

Error message

INX100: 810006 Stop sequence timed out followed by error codes 1610006 Stop sequence timed then 1600010 XRImProc did not received any DL frame during the last 1000msecs. 810006 Stop sequence timed out AR XRDataMgr acquisition File_Corruption_Data_base is logged in the error log, followed by 1610006 Stop sequence timed out AR XRImProc acquisition Component(s) _DL_Image_Processing_boards 1 0 (null) DLGenericActorContext DL and then error 1600010 ImProc compares a different frame number between CF last notification and last image received on fiber link. 1 to 6 images may have been lost. AR XRImProc control Component(s)_DL_FCIM_board 1 0 XRImProc did not received any DL frame during the last 1000msecs This sequence indicates the DL did not receive images as expected from the RTAC

DL 810006, error Text = Stop sequence timed out FOLLOWED BY 1610017, error Text = Unable to get property as requested, debug Text += Last frame Id FOLLOWED BY 1610006, error Text = Stop sequence timed out. Check 1600010 er System impact: exam failure. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service" Look at Cause error 1600010 System impact: exam failure. Displayed message 

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Component
FCIB board 5189435 FCIB board FRU number 5189435 FCIB board FRU number 5189435
Area
X-ray Vascular