Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
INX100: 810006 Stop sequence timed out followed by error codes 1610006 Stop sequence timed then 1600010 XRImProc did not received any DL frame during the last 1000msecs. 810006 Stop sequence timed out AR XRDataMgr acquisition File_Corruption_Data_base is logged in the error log, followed by 1610006 Stop sequence timed out AR XRImProc acquisition Component(s) _DL_Image_Processing_boards 1 0 (null) DLGenericActorContext DL and then error 1600010 ImProc compares a different frame number between CF last notification and last image received on fiber link. 1 to 6 images may have been lost. AR XRImProc control Component(s)_DL_FCIM_board 1 0 XRImProc did not received any DL frame during the last 1000msecs This sequence indicates the DL did not receive images as expected from the RTAC DL 810006, error Text = Stop sequence timed out FOLLOWED BY 1610017, error Text = Unable to get property as requested, debug Text += Last frame Id FOLLOWED BY 1610006, error Text = Stop sequence timed out. Check 1600010 er System impact: exam failure. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service" Look at Cause error 1600010 System impact: exam failure. Displayed message
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- FCIB board 5189435 FCIB board FRU number 5189435 FCIB board FRU number 5189435
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.