GE Healthcare · X-ray VascularInnova50108
164906 50108 Power Voltage failure error is logged intermittently in the SUIF or detected by Healthpage.
Symptom
50108 Power Voltage failure error is logged intermittently in the SUIF or detected by Healthpage. The gantry functions properly, no customer issue is reported. 50108 Power Voltage Failure error is logged intermittently in the SUIF, detected remotely, by an FE on site, or detected by Healthpage. The gantry functions properly, no customer issue is reported.
Error message
CARC error Code = 50108, error Text = POS SMA: power voltage failure, debug Text += pos-error=4AB9, hw-status=0002, recovery Class = DO, major Function /= LC Gantry C_ARC Degraded Motion displayed. Gantry Motion may or may not be inhibited. Error code 50108 HW = 0002 FRT_ARC. System impact: Degraded gantry motion. Displayed message : None. 0000 FRT_L 0001 FRT_PVT 0002 FRT_ARC 0003 FRT_II
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Software
- $ Innova 2000 LVA, DL. 13.4.1 for (DL1, DL2). FMI 12044 Innova 2000, LVA (DL1, DL2). DL 13.2.1 through 13.4.1 FMI 12044 This FMI is "Mandatory on Request" for Innova 2000 LVA upgrades, but also has the collision SW. The FMI is for DL1 and DL2 systems only, should we install it on more DL1 & 2 systems for the collisions? Innova 2000, LVA (DL1, DL2). DL 13.2.1 through 13.4.1. FMI 12044 Ghost (*) DL Ghost Image X – revision Y DL 13.4.1 DL Atlas Core 3.1O-1 RTAC Atlas Core 3.1O-1 IDC 2.14 Calypso 11.14 Titan H0 .60 Positioner Roadrunner 5.5 LVA-2 Positioner Motorola 5.0V NOTE: This FMI is "Mandatory on Request" for Innova 2000 LVA upgrades, but also has the collision SW. The FMI is for DL1 and DL2 systems only, should we install it on more DL1 & 2 systems for the collisions?
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.