Unable to start Medical Application package on DL
Symptom
INX1PRO-IQ+: Unable to start Medical Application package on DL INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA QCA (Quantitative Coronary Analysis), LVA QVA (Quantitative Ventricular Analysis) INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA <=> QCA (Quantitative Coronary Analysis), LVA <=> QVA (Quantitative Ventricular Analysis) when starting Stenosis Analysis on ITU.
Error message
1050188 TBLROT ENC FAILURE DO Table Speed Degraded Frt_TBLROT_ENC_FAILURE- Table rotation encoder failure encoder not calibrated (T:0x4B13 H:0x000B U:0x0001) 1050188 TBLROT ENC FAILURE DO Table Speed Degraded Frt_TBLROT_ENC_FAILURE 0 0 - Table rotation encoder failure encoder not calibrated (T:0x4B13 H:0x000B U:0x0001) Z:/heroic/table_rotation.c 238 This error can be generated due to the rotational encoder never being calibrated. As a side effect, this error may be followed by many errors 810012 Front: Invalid parameter received DO Debug: (null) (after a record acquisition for example). 2800029 WR XRSubSysMgrDLDatabase inconsistency failure 2800029 WR XRSubSysMgrDLDatabase inconsistency failure. Debug: No MedApp can be made on this sequence because field (0x0019, 0x8F, 'GEMS_DL_IMG_01') contains NO_QCA value -> acquisition issue Error logged in errorlog file when attempting to start Medical Application. Note : you may have following errors after a record acquisition: 1050187 Table Rotation encoder Comm lost Error 1050187 Table Rotation encoder communication lost. See long description for further details. Error 1050187 Table Rotation encoder communication lost. In the errlog, we g
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.