3D calculation process in SUIF fails before normal completion

Symptom

INX1PRO-IQ+: 3D calculation process in SUIF fails before normal completion, resulting in 3D calibration failure INX1PRO-IQ+: 3D calculation process in SUIF fails before normal completion. See long description for further details. INX1PRO-IQ+: 3D calculation process in SUIF fails before normal completion. Select SUIF, start the 3D calibration procedure. Follow procedure to acquire all helix sequences (ie 2 acquisitions if 3D option only enabled, 6 acquisitions if 3D + CT options enabled). When all acquisitions have been acquired, the 3D calculation process is started. Problem observed: 3D calculation process is aborted prior 100% completion, thus the system cannot be calibrated for 3D. There is no obvious message telling user why the calculation failed. Sometimes, a message related to Fluoro store may be displayed on the live monitor (can be "Disk full: fluoro cannot be stored. Delete archived patients" that has no relationship with the 3D calculation failure)

Error message

1200007 Front: Functional error with Debug “Unexpected event PROCESS_CALIBRATION_DONE received while in state ACTOR_SEQUENCES__CONFIGURATION_SEQUENCE__OPMODES_CONFIGURATION__CONFIGURATION” This error may be followed or preceeded by 810007 Front: Generic Software Error 1200007 Front: Functional error with Debug text “Unexpected event PROCESS_CALIBRATION_DONE received while in state ACTOR_SEQUENCES__CONFIGURATION_SEQUENCE__OPMODES_CONFIGURATION__CONFIGURATION” This error may be followed or preceeded by 810007 Front: Generic Software Error

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Software
$INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144. Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production.
Area
X-ray Vascular

Full cause & step-by-step resolution