160091 Innova, Image Quality Degraded

Symptom

Innova, Image Quality Degraded Image Quality Degraded

Error message

3800315 Text = Received bad value from IDC for sensor Fbck, debug Text = (null), recovery Class = DO, major Function /= XRTechOpt 3800315 Text = Received bad value from IDC for sensor Fbck, System impact: Possible image quality issue. Displayed message : None. You may see this in testing if you use lead or other thing to Fluoro. The system can not adjust dose correct from the last exposure to the new. because lookup conv table. Step to high for normal then step to low causing the image to change levels., You need aluminum block. Calibration issues If a issue check Digital Detector Calibration 3800315 Text = Received bad value from IDC for sensor Fbck, System impact: Possible image quality issue. Displayed message : None. You may see this in testing if you use lead or other thing to Fluoro. The system can not adjust dose correct from the last exposure to the new. because lookup conv table. Step to high for normal then step to low causing the image to change levels., You need aluminum block. Calibration issues If a issue check Digital Detector Calibration

Applies to

Models
Innova
Product
Innova 2000 Innova 2000 systems Innova 2000 systems
Software
$ Innova2000, HER_M6_12.31, M6 release to be used with DL6/RTAC6 hardware Innova2000 M6 release to be used with DL6/RTAC6 hardware on Innova 2000. Heroic M6 release to be used with DL6/RTAC6 hardware on Innova 2000.
Component
Innova 2000 Digital Detector Digital Detector; 2270465, Heroic 20cm Apollo detector CRD or PKI 2270465-2, Heroic 20cm Apollo detector PKI, 2232205, Heroic 20cm Apollo detector CRD, Status and 2232205-2, Heroic 20cm Apollo detector PKI, Status: Non Orderable Always use the most appropriate documentation for your system. The following was taken from Direction 2394605-200 Rev 1 and is provided for your reference: Digital Detector; 2270465, Heroic 20cm Apollo detector CRD or PKI 2270465-2, Heroic 20cm Apollo detector PKI, 2232205, Heroic 20cm Apollo detector CRD, Status and 2232205-2, Heroic 20cm Apollo detector PKI, Status: Non Orderable Always use the most appropriate documentation for your system. The following was taken from Direction 2394605-200 Rev 1 and is provided for your reference:
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues