GE MR — field troubleshooting
9,114 field-service issues · page 100 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- RRF Data Path Exc Rec Signal Test goes over the allotted time (remaining time goes negative) and reports error 2247144 with an odd frequency used.MR · 2247144
- Unable to Graphically Prescribe off of a 3-plane Localizer.MR · 2224340
- cannot scan due to RF errors.MR · 2225713, 2225714
- Uneven or Incomplete Fat Saturation with Invivo HDX 8 Channel NV Array Coil in NVARRAY_A Configuration in Neck and Brachial Plexus Studies.MR · 5147135, 13090646
- Cannot scan. Replaced gradient switch.MR · 2244653
- Corrupt Image DatabaseMR
- Syntax Error in Line 0 Message Due to CoilConfig.vf file is empty.MR · 2227566
- 2220090 Internal software error Due to CoilConfig.vf File is Empty. 3T Excite HDx 14.0. 2220090 Internal Software Error.MR · 2220090
- POMP and 3DTOF PSD Failed to Download due to Defective Octane1MR · 2217489, 2218624
- MRIQ Coherent Noise Due to Body Heliax Connector.MR · 15000, 638474600
- ReportCARD 3.0 Customer Release Notes and Errata Needed.MR
- Wide Borders on Films from Sony Film Station.MR
- Can We Use a CRM QUAD HEAD COIL 46-282118G202 to Troubleshoot a 9.1 BRM system?MR
- Defective Coil ID path through Preamp, IMA and IMA ControlMR
- Longitudinal Drive Calibration Does Not Converge. 3T Excite HDx 14.0.MR
- MRIQ Bright or High Intensity Dot or Signal in 3D FLAIR Sequence on 3T Excite HD 12.0.MR
- The Patient's Name Appears in the Images and Films with a Question Mark ? at the End.MR
- HIS RIS Worklist Displays SPS Start Date of 01/01/00 and Birth Date of 01/01/1900.MR
- Intermittent ROTMI Calculation Errors Due to too broad of a detection for radial prescriptionsMR · 2218692, 2218694
- The Performed Procedure Step option was installed and it caused this issueMR · 123456
- How Can I Find the Software Version an Image Was Scanned On.MR
- Unable to Boot ReportCARD 2.0 Workstation due to Pins 4 & 8 Were Bent Over and Touching on Rear of Hard Disk Drive Inside Computer Chassis.MR
- ACR Slice Position Accuracy Test Fails.MR
- Unable to Post Process PROSE Image Set in FuncTool2 Program.MR
- Unable to install mini root during the software load from cold.MR
- System Crash After Date Change and Will Not Boot.MR
- What is the Speed of the Network On Unix Systems.MR
- Daylight Savings Time Change.MR
- The NIC card is causing communication errors to the MGD Chassis.MR · 2223817, 200002322
- MRIQ Ghosting and Digital Artifacts.MR
- Auto Window Width/Level WW/WL Not Applied Evenly Across Series.MR · 13100834
- U41 of AGP Board Appears to be Burned, but AGP Continues to Function, Should We Replace It.MR · 13093613
- MR-Echo FIESTA Scans Intermittently Abort Midway Through an Acquisition.MR · 2258024
- MR010014 PDS - EQUIP ENV Alert - Chronic Humidity Issues Detected.MR
- PURE Calibration Scan Invalid, Not Recognized, But It Was Run.MR · 2228004, 31214
- Fuse F10 on RFSC Power Supply Board was Blown.MR · 2224709, 2224580
- CWA ID74638. AP will not Initialize after Power Hit.MR · 2227996
- ACR American College of Radiology Accreditation Requires Images to be Submitted on CD-ROM, but this System Cannot Write to CD-ROM.MR
- Replaced bad I or Q heliax cable leading to the body coilMR
- Shim Plate Change on Shinetsu MagnetMR
- Unable to Scan Diffusion Weighted EPI Due to Poor Seating of CERD Receiver # 1.MR · 2218537, 2221976
- Defective Patient Handling Power Supply Module (PHPS).MR · 2262606
- What Codes are used to define RF Amplifier Type.MR · 2225487
- Accidental Push of E-stop Button.MR · 2248602, 2252318
- CWA ID74708. PDU was in stop modeMR · 2224666
- Cannot Bring Up iLinq Browser.MR
- Protocol PSD Download FailsMR · 2227387
- Action Items sent from the RIS are not mapped out or associated to protocols in the SCP tab in the GUI.MR · 2219940
- Body TR Bias Not Present at Output of Body Heliax.MR · 2252305
- UCERD Exciter was cause of TPS download failuresMR · 2223832, 2223823
- The Ellis & Watts Main Disconnect Panel MDP Will Not Power On After Power Outage To Site.MR
- MRCustomerCall Fine line Artifact Due to an Uneven NEX.MR
- The Y axis Master 8607 Gradient Amp did not have a grafidy board on itMR
- Some customers decline Magnet Monitor or Insite connectivity due to security, privacy, or other network concerns.MR
- Zipper due to RF Leak due to Screen Room Door Threshold or Sill being Extremely Dirty and Two Small Holes in Pen Panel.MR
- Bug in Functool 2.5.36c software as contained in 9.1 Patch 13L.MR · 2224358
- FE Used Wrong Command, conf, to Find Host ID for eLicense. sysinfo is Correct Command.MR
- Coil ID Fails. Re prescribe Scan After Ensuring the Connected Coil Matches Prescribed Coil.MR · 2220007, 2218630
- Scan Inhibited Due To Gradient Cooling Unit Not Cooling Circulating Water.MR · 2248652
- Found that earlier in the day an older MOD was put into the drive for a Restore function.MR
- PDU was in stop mode.MR · 2225704, 2225697
- No Clock Signal Due To an open primary winding on the low-voltage AC line clock transformer.MR · 2248356
- The Power, Reset Buttons, and Indicator Lights Were Not Wired to the Mother Board of the PC Computer.MR · 2284297, 13085962
- The CAN Link is Reporting Hard or Intermittent CAN Link Failures.MR · 2252236, 2252230
- Can I Run PM Assist or PM Check Remotely.MR
- MGD And Host Have Lost Sync.MR · 2249372, 1706269
- SPT fails to run the body section of the test Due to The Table will not advance to the 1135 location.MR · 2224727
- Ghosting Only On T2 FLAIR Scans Due to X-Axis SGA.MR
- Corrupt Coil Configuration File.MR · 3000004, 2257110
- How Do I Change From AM PM Time Format to Military 24 Hour Time Format.MR
- Appears the X and Y Coil Drive is swapped Error Due to DQA Phantom Fluid level.MR
- After LFC Unable to Reset TPS Common Service Desktop Missing and Hostmonitor Timeout Error.MR · 13099619
- Scan Pause and Bright Zipper or Band in Images caused by TWIN GRAD SWITCH BOX.MR · 2244655
- ERBTEC RF Amplifier fault 84 after reseting the TPS, generic MDS link errorsMR · 2225693, 2225512
- Restore Protocols From MOD Must Be From Same Scanner Software Platform.MR · 10032
- Why doesn't a spec exist for LVShim on Ovation?MR
- OrthoMRI How to change the IP Address on E-Scan Win Systems.MR
- Early failure of HFA-S-LITE CUV Error Current Under Voltage Troubleshooting Notice.MR
- Auto and Manual Prescan Fails.MR · 2224666
- MRID 7channel Breast Coil Wont Scan Vibrant Protocol Due to Vibrant Configuration.MR