- When new landmark is made, and new localizer image is created, in the Graphic Rx of unsaved series, the old localizer image may still be displayed and used for slice setting.MR
- When performing MRA imaging, When collapsed image turned on in vascular screen, images appear in autoview and browser appear to be magnified, elongated and beyond the original field of viewMR
- There is a label displayed near the [Scan] button, which may wrongly display "First Level".MR
- Unable to perform Head Scan because of UPM Body Peak Power faults.MR · 2254782, 13444
- Corrupt Protocol.MR · 2219663
- Unable to Access the CD/DVD Drive due to the SCSI Tower was Powered Off During the Host Computer Software LoadMR
- The System Clock Was Incorrect.MR · 2228179
- Gradient Control Board not Communicating with the MGD.MR · 2248674, 2248662
- Improper Network Speed Setting Causes Slow Image Transfers.MR
- Software was corrupted due to a bad block on the hard drive.MR
- Both eth1 and eth2 are configured as IP Address 192.168.0.1MR · 2227915
- Multicoil Bias Fault Detected Short Circuit due to wire bearing the MC4 bias current crushed between the halves of the Run 4110 cable at J19 of the 8ch Switch.MR · 2252303
- Things to check when Cold head temperature and or RUO temps are not reading at SHEM magnet monitor correctly at 0 or 24 degreesMR
- unexpected table drive into bore at full speed. 11.0MR
- Geometry errors Due To Software Update ServicePack-02.MR · 2218682
- What are Gather Load Data test results from a normal HFO5 system using the OpenSpeed USAI GE Signa OpenSpeed MILLENNIUM 5000 HFO NEUROVASCULAR ARRAY GE Catalog Part Number.MR
- Part numbers found on some of the HDx (14.0) coil component labels are not the numbers that should be used to order a FRU replacement.MR
- OrthoMRI Customer has selected the wrong bed positionMR
- Z2 Supply front panel output to Fluke cable is disconnected or faulty message is being logged.MR · 2249624
- Cannot scan an Abdomen sequence because of various TPS, Gradient and RF Amp errors.MR · 2252738
- Auto Prescan Fails With Could Not Set the Z2 Shim.MR · 2249631, 2249677
- One of the TNS assemblies had no power.MR · 2224666
- Application Software does not complete the boot process with TPS Download failure.Shutdown Software and Power Off the HP Power Cycle Systems Cabinet via PDU.MR · 200002348
- auto prescan fails with erbtec 85 fault, but only on sagittal T2 scan.MR · 2213312
- Can Not Scan. Excite HD 12.0. 2248131 APS DC Send DRF info error.MR · 2248131
- Unable to Download or Reset The TPS MGD or ISEMR · 2224932, 2209284
- Daylight Savings Time Change.MR
- Unable to Boot Applications Software and TPS Download Fails due to Minerva II AP Master in the MGD Chassis.MR · 2223817, 2223849
- CWA ID 73160 Unable to Download or Reset The TPS MGD or ISEMR · 2237273, 2237285
- Common Service Desktop Software Bug.MR
- The /usr/g/hisris/wlsErrors file was incorrectly owned by root Worklist update fails, but no errors are logged in the /usr/g/hisris/wlsErrors file.MR
- Future BRM Gradients 2124499-7 & 2124499-3 have been modified in the region of aluminum support plate attachment (2213167-3 & 2213168-3).MR · 2124499, 2213167
- New GE MR Chiller Vendor Service Request Process for USMR
- Unable to Scan with 1.0T CTLBOT due to Multi-Coil T/R Driver Fault.MR · 2224583, 2225558
- Table Is Getting Stuck Is Due To The Hook.MR
- Corrupt Image Database.MR · 10182
- Cycle Power to the System and Press the EMO Reset Button on PDU Cabinet on Power-up.MR · 2254347, 2254342
- Failures on the Z Axis when running the Gradient Fidelity Test.MR · 2245297, 33644216
- Will Not Scan With RF Errors.MR · 2254052
- How to Install Patches from CDROM on Linux Based System.MR
- Octane Computer Hangs With Errors.MR · 195805184
- AirSys Chiller Initial Checkout Procedure Unclear. 3T Excite HD 12.0.MR
- Scanner noise causes longitudinal encoder counts and pauses the scan until advance to scan and start scan buttons are pressed.MR
- Intermittently unable to download or scan the Propeller PSD Due to the Eight Port Ethernet Switch.MR · 2257100
- Unable to Boot Applications Software due to TPS Reset Failure.MR · 2223817, 2223849
- Defective Octane I System Module Brick OPTION 195MHZ PROCESSOR MODULE.MR
- Unable to Boot or Power Up 3T RF Amp. 3T Excite HD 12.0. 2254352 RF Amplifier Serial Link FailureMR · 2261230, 2223817
- MRI Slice-to-Slice Misalignment of Reformats of Abdominal Region using the Cardiac coil.MR · 13094076
- MRIQ One Leg Brighter with Poor Background Suppression.MR · 13094034
- The table top is made up of individual sections.MR
- OrthoMRI Wiring base for the number 2 (knee) coil had frayed wiresMR
- Will Not Scan With Power Monitor Faults Due To The APM Board In The SSM.MR · 2254052
- OrthoMRI Getting an error when running a scout.MR · 18004
- Unable To Bring Up Fe tools Due To Alt O is Not a Supported Command with Mozilla Browser.MR
- How to interpret failing open circuit Gather Load data results to determine if the HD coil is bad versus the LPCA port.MR · 2252301
- Mobile Message Log Missing Information.MR
- The pointer and the frame whether the field to enter the value on Graphic Rx window is not be shown when Graphic Rx window is open.MR
- Cannot DICOM Network Images Due to A back slash in the Protocol Name.MR · 11057
- The new graphic prescription will not be able to prescribed occasionally after the prescribed all slices are erased by [Erase All] button.MR
- Ways to Minimize Blurring or Ghosting Artifacts with 2D FSE, FRFSE, FSE-IR, T1FLAIR, T2FLAIR. with Phase Correct.MR
- Auto Prescan Failed, RF Amplifier is not readyMR · 2254352, 2254347
- Intermittently Unable to Scan using the MRID 1.5T T/R Knee/Foot Coil due to T/R driver fault, head path short Errors.MR · 2249150
- PM Check and thus IBIS Fails for LVShim, but the Data Passes and SPT and LVShim were run within 24 hours of each otherMR
- Unable to Scan using the MRID 1.5T T/R Knee/Foot Coil due to error Multicoil Bias Fault Detected Open Circuit.MR · 2252301
- Intermittent ROTMI Calculation Errors Due to too broad of a detection for radial prescriptions.MR · 2218674
- Scan room temperature was warmer than normal.MR · 2248652
- Second Opinion Part Number 2194003-2 Sumitomo Cold Head and Gasket Kit.MR
- Unable to Download or Reset The TPS MGD or ISE.MR · 2257200, 2223619
- Does a Fat Sat Troubleshooting Document exist.MR
- Will Not Scan with No Respiratory Trigger Gating Signal Found.MR · 2218527, 2227337
- CWA ID73745. Will Not Scan with Gradient Errors.MR · 2250081
- Image Database does not Respond or Update.MR · 10097, 2224358
- No signal in Head Transmit Mode due to Head RF Transmit Cables Swapped between MSHSII J1 & J10.MR
- Auto Prescan Fails Due To Center Frequency Off By 2000hz.MR · 2224666
- Log Entries in /var/log/messages Bear a Future Date/Time Stamp.MR
- What is the Part Number for the Hand Held Gauss Meter?MR
- Can Not Scan. Reset Image Data Base Using GUI.MR · 2218527
- Working with the customer over the phone...need to talk them through a reboot.MR
- No or Low signal from Coil Element 5 of USLS456 Coil Array.MR
- With the Front Enclosure Microphone Connected, Neither Microphone Works.MR