Intermittent ROTMI Calculation Errors Due to too broad of a detection for radial prescriptions
Symptom
Intermittent ROTMI Calculation Errors Seen at Download See Long Description SMILe March 5, 2007 This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Subject: Intermittent ROTMI Calculation Errors Seen at Download And Recommended Customer Workaround. Effectivity: All Signa 1.5T and 3.0T MR Systems operating with 11.0M4 SP1, 12.0M5 SP2, 14.0M4 SP1, and 14.0 SP2. Problem: Sites have reported intermittent ROTMI calculation errors at download time for specific pulse sequences. The following error message is logged in the gesys log: "Rotmi Calculation Error found during Download". This error text corresponds to error codes 2218692 (14.0 platform), 2218717 (12.0 platform), and 2218674 (11.0 platform). This issue primarily occurs on Radial and MSMA prescriptions. In 2006 a potential safety issue was reported and, to prevent scanning after a geometric calculation error, a download failure that resulted in an error message stating, "Rotmi Calculation Error found during Download" was introduced. Unfortunately, this fix used too broad of a detection for radial prescriptions. Resolution: When a ROTMI error occurs the workaround is to force a recalculation using very slightly different locations that cover the same anatomy. Do not simply reuse the failing graphic prescription. Ask the customer to perform these steps: View-Edit the current Series which has the download failure. On the GRx window, select the slices. Click [Erase Selected]. Re-prescribe the graphic prescription. Do not use Copy-Rx. Do not copy/paste the GRx prescription. Do not use Copy-Series or Paste-GRx from the series which had the download failure. A new version of the preventive fix, which more precisely detects an error, is in validation at this time and will be released as soon as possible. Field Engineers and Apps Specialists : Notify the site and advise of the above workaround. Verify that the workaround is being implemented correctly. If the workaround is unsatisfactory, please enter a product complaint (PQR/iTrak) and, if necessary, contact OnLine Center support. Jacqui Budde Software Engineering GE CONFIDENTIAL! © 2007 General Electric Company CLASS M DOCUMENTATION--PROPERTY OF GENERAL ELECTRIC COMPANY FOR USE BY GE PERSONNEL ONLY ANY OTHER USE EXPRESSLY PROHIBITED
Error message
2218692 Rotmi Calculation Error found during Download 2218692 "Rotmi Calculation Error found during Download" 2218694 Slice:FreqMatError:Incorrect Rotmi row[1] = 0.048462 0.000592 0.998825 Error: 2218694 Host: mr02 Process: scn File: RxManagerIF.m Line: 976 Slice:FreqMatError:Incorrect Rotmi row[1] = 0.048462 0.000592 0.998825
Applies to
- Models
- Excite, Signa
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.