GE Healthcare · X-ray VascularInnova

After Customer performed EPO the 20KVA UPS would not turn on properly and provide power the system.

Symptom

After Customer performed EOP the 20KVA UPS would not turn on properly and provide power the system. Customer performed a EOP to reboot the system after it hung and then when they tried to bring the system back online the 20KVA UPS would not turn on properly.

Error message

The 20KVA Display showed "error 4100 rectifier Fuses Failure"

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Software
$INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144. Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production. SPAD M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1 SPAD (Biplane) M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1 - MCB fix is related to frontal LC vibrations fix. SPAD (biplane) M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1. MCB fix is related to frontal LC vibrations fix. SPAD M4 TR1 BIP_5.11.0 DL_SPAD_4.23.1 SPAD M4 TR1 BIP_5.11.0 DL_SPAD_4.23.1 SPAD M4 TR1 BIP_5.11.0 DL_SPAD_4.23.1 $ Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9 FMI 12105 Unity M4 SP3.2 DL_Unity_4.18.9, FMI 12105 healthpage tag for this software is UNITY_M4_FMI_4.21 212009270 03/26/2010 13:31 GMT $ M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $ INX1PRO or IQ+,Harmony_M3 INX1PRO or IQ+, Harmony_M3 Product is called INX1PRO or IQ+: Harmony_M3 sw release applicable to Harmony systems. $ IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 $ INX1PRO or IQ+, Pathfinder_M3, DL_PATHFINDER_1.17.1 $ INX1PRO or IQ+, Pathfinder_M3, DL_PATHFINDER_1.17.1 $ INX1PRO or IQ+, Pathfinder_M3, DL_PATHFINDER_1.17.1 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 Date 01-01-2010 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 SP4 SYSTEM RELEASE UIS 4.52.1 DL GHOST 22.2.3 DL DL_Unity_4.19.14 GITANE V7.47 ITU OS: 2.2.4.6 RAFI: 1.11 GE: 1.3.3 Calypso CLY.PLATFORM 4.52.XX IDC 5.39.XX GITANE V9 FW1.5 POS CPU RR POS LBY 1.4.4U_23 PST 1.9.D PIB SW V3.6 FPGA V4.3 (with every type of interco lift) MCB DSP 34F / FPGA317 STEPPER BOARD IS6.31L JEDI P6.36BF1 AW AW4.4_04 or AW4.3_05.04 or AW4.2_07 3DXR 1.0.5.XX VOLUME VIEWER 6.5.0 or 6.7.0 or 6.8.3 or 7.4.71 $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 M3 release for Alliance program (IQ table (tilting table) introduction on Harmony configuration).
Component
SG-20 KVA UPS SG-20 KVA UPS Seelong. SG-20 KVA UPS OPM_SGS_USM_10K_40K_0US_V010.pdf 5380482 UL PDB Phase Control Relay LS1
Area
X-ray Vascular