GE Healthcare · X-ray VascularInnova40013400008010456361041
Innova, The worklist query returns some patients, but not all the patients that should be there.
Symptom
Innova, The worklist query returns some patients, but not all the patients that should be there.
Error message
Innova MWL log indicates error messages referencing "attribute tag validation violations" See long description for an example. Innova MWL log indicates error messages referencing "attribute tag validation violations" DATE: 10/27/10 13:51:07 HOSTNAME: DLBP1 PROCNAME/PROCID: None/1,720 THREADNAME: 2,508 PRIORITY: 2,147,483,647 DESTHINT: [MwlDestinationHintMask]1:1 TEXT: DJR -> root error= 4090; final Error=1004; Message= MC_Validate_Message() : Patient Name = TEST^CASE : Patient ID = 4001340 : Tag = 00080104 ---------- DATE: 10/27/10 13:51:07 HOSTNAME: DLBP1 PROCNAME/PROCID: None/1,720 THREADNAME: 2,508 PRIORITY: 2,147,483,647 DESTHINT: [MwlDestinationHintMask]1:1 TEXT: Attribute tag with validation violation = ---------- DATE: 10/27/10 13:51:07 HOSTNAME: DLBP1 PROCNAME/PROCID: None/1,720 THREADNAME: 2,508 PRIORITY: 2,147,483,647 DESTHINT: [MwlDestinationHintMask]1:1 TEXT: Validation failed, Record rejected ---------- DATE: 10/27/10 13:51:07 HOSTNAME: DLBP1 PROCNAME/PROCID: None/1,720 THREADNAME: 2,508 PRIORITY: 2,147,483,647 DESTHINT: [MwlDestinationHintMask]1:1 TEXT: JobId : 56361041; Result received = 17 records ---------- DATE: 10/27/10 13:51:07 HOSTNAME: DLBP1 PROCNAME/PROCID: N
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- $ M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108 $New, M4 SPAD BIP_4.18.5, DL_SPAD_4.15.1 FMI 12108 or $ new, Innova Biplane M4 BIP_4.18.5, DL_4.15.1 FMI 12108
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.