INJECTION FAILED X-RAY ABORTED; during a run or run-off after the mask image.
Symptom
INNOVA: INJECTION FAILED X-RAY ABORTED; during a DSA aquisition or run-off after the mask image. The injector has failed to inject. The Innova aborts X-ray during a DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested. The Innova aborts X-ray during DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested.
Error message
2400017 Failed to start injector followed by: 1610034 IP software error followed by: 2400011 Injector became unarmed during sequence 2400017 AR XRPeriDevCtrl Failed to start injector Debug: Injection failed, please restart followed by: 1610034 DO XRImProc IP software error Debug: Blacken requested by fibre channel command on Frontal Followed by: 2400011 WR XRPeriDevCtrl ALARM (! , 1.8) - Injector became unarmed during sequence Debug: [XRPeriDevCtrl::onInjectorDisArmed] Injector is not armed 2400017 Debug: Injection failed, please restart followed by: 1610034 Debug: Blacken requested by fibre channel command on Frontal Followed by: 2400011 Debug: [XRPeriDevCtrl::onInjectorDisArmed] Injector is not armed
Applies to
- Models
- Innova, Advantx
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 $ IQ+ or PRO table ALLIANCE M3 ALL_2.2.16 M3 release for Alliance program (IQ table (tilting table) introduction on Harmony configuration).
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.