Tube Chiller low fluid alarm, The Chiller is making a beeping sound and the bowl indicator is lit.

Symptom

Tube Chiller low fluid alarm, or Healthpage reports The Chiller is making a beeping sound and the bowl indicator is lit. Reported by Healthpage as tube low level alarm. This error is reported via serial connection to the Jedi, and will be logged in the error log if the serial connection is present and working. Tube Chiller low fluid alarm, or Healthpage reports The Chiller is making a beeping sound and the bowl indicator is lit. Reported by Healthpage as tube low level alarm This error is reported via serial connection to the Jedi, and will be logged in the error log if the serial connection is present and working. If The Serial cable is absent or defective the Tube Chiller will sound this alarm when the reservoir is 2/3 full and the float switch is activated. The bowl indicator with low fluid will light on the front panel of the chiller.

Error message

INX100 : 3602084, error Text = Chiller: alarm sent, debug Text += jedi-error=814h, chiller alarm sent: Low level alarm, recovery Class = DO, major Function /= XRTechMgr INX100 : 3602084, error Text = Chiller: alarm sent, debug Text += jedi-error=814h, chiller alarm sent: Low level alarm, recovery Class = DO, major Function /= XRTechMgr. System impact: None. Displayed message : None. 3602084 DO XRTechMgr Chiller: alarm sent Debug: jedi-error-code=814h JEDI Error Code: 0814H chiller alarm sent: Low temperature alarm, Temperature in degrees celsius: XX Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
Component
Positioner Gantry Positioner Gantry Positioner Gantry Coolix XR Tube Chiller Coolix XR Tube Chiller Coolix XR Tube Chiller
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.