Tube Chiller low fluid alarm, The Chiller is making a beeping sound and the bowl indicator is lit.
Symptom
Tube Chiller low fluid alarm, or Healthpage reports The Chiller is making a beeping sound and the bowl indicator is lit. Reported by Healthpage as tube low level alarm. This error is reported via serial connection to the Jedi, and will be logged in the error log if the serial connection is present and working. Tube Chiller low fluid alarm, or Healthpage reports The Chiller is making a beeping sound and the bowl indicator is lit. Reported by Healthpage as tube low level alarm This error is reported via serial connection to the Jedi, and will be logged in the error log if the serial connection is present and working. If The Serial cable is absent or defective the Tube Chiller will sound this alarm when the reservoir is 2/3 full and the float switch is activated. The bowl indicator with low fluid will light on the front panel of the chiller.
Error message
INX100 : 3602084, error Text = Chiller: alarm sent, debug Text += jedi-error=814h, chiller alarm sent: Low level alarm, recovery Class = DO, major Function /= XRTechMgr INX100 : 3602084, error Text = Chiller: alarm sent, debug Text += jedi-error=814h, chiller alarm sent: Low level alarm, recovery Class = DO, major Function /= XRTechMgr. System impact: None. Displayed message : None. 3602084 DO XRTechMgr Chiller: alarm sent Debug: jedi-error-code=814h JEDI Error Code: 0814H chiller alarm sent: Low temperature alarm, Temperature in degrees celsius: XX Tube 1 70C: OK, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed Phase: STAND_BY
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry Coolix XR Tube Chiller Coolix XR Tube Chiller Coolix XR Tube Chiller
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.