GE Healthcare · X-ray VascularInnova00400003
168180 Innova, When performing a worklist Query the DL status bar indicates "Worklist Query Failed"
Symptom
Innova, When performing a worklist Query the DL status bar indicates "Worklist Query Failed" Innova, When performing a worklist query the DL status bar indicates "Worklist Query Failed"
Error message
Innova: mwlServer.log reports EXT: DJR - root error= 4090 ; final Error=1004; Message= MC_Get_Value_Count() : Patient Name = xxxx^xxxx : Patient ID = xxxx : Tag = 00400003 Root Cause 4090 Indicates the worklist broker has not populated DICOM Tag 0040,0003 properly. Tag 0040,0003 is the Scheduled Procedure Step Start time. The Value may not be null. mwlServer.log reports EXT: DJR - root error= 4090 ; final Error=1004; Message= MC_Get_Value_Count() : Patient Name = xxxx^xxxx : Patient ID = xxxx : Tag = 00400003 Root Cause 4090 Indicates the worklist broker has not populated DICOM Tag 0040,0003 properly. Tag 0040,0003 is the Scheduled Procedure Step Start time. The Value may not be null.
Applies to
- Models
- Innova
- Product
- X Innova 4100 X Do not use---------4100 systems 4100 systems
- Software
- $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 Date 01-01-2010 $ Unity M4 SP4, DL_Unity_4.19.14, FMI 12118 SP4 SYSTEM RELEASE UIS 4.52.1 DL GHOST 22.2.3 DL DL_Unity_4.19.14 GITANE V7.47 ITU OS: 2.2.4.6 RAFI: 1.11 GE: 1.3.3 Calypso CLY.PLATFORM 4.52.XX IDC 5.39.XX GITANE V9 FW1.5 POS CPU RR POS LBY 1.4.4U_23 PST 1.9.D PIB SW V3.6 FPGA V4.3 (with every type of interco lift) MCB DSP 34F / FPGA317 STEPPER BOARD IS6.31L JEDI P6.36BF1 AW AW4.4_04 or AW4.3_05.04 or AW4.2_07 3DXR 1.0.5.XX VOLUME VIEWER 6.5.0 or 6.7.0 or 6.8.3 or 7.4.71
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.