GE MR — field troubleshooting
9,114 field-service issues · page 32 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- How to Turn Off Grayscale Softcopy Presentation State (GSPS).MR
- Error Message When Executing MCQA Tool, MCRV tool has not been run or no data from the MCRV tool.MR
- T/R Driver fault short caused by defective 50 ohm resistor in the Body Hybrid.MR · 2225520
- Does the MEDCAM Baseboard p/n 2292662-11 Require Terminators?The MEDCAM Baseboard p/n 2292662-11 Does Not Use Terminators.HF OpenSpeed.MR · 2292662, 2250758
- Gradient Diagnostic Failure due to STIF or SRF/TRF I/O Board Failure.MR · 2250108, 2250106
- How to Add, Update, or Delete a Network Host.MR
- Manual Prescan failed Due to Devices are emulated.MR · 2224667, 2224666
- Analogic 8280 Gradients Fail to Come Up with HV PS Fault Due to Gradient Amplifier.MR · 2240308
- CWA System Monitor Has a Dark Area on the Screen.MR · 200002352, 200002
- Scan Range in Guided Install Changes From Long to Short on Guided Install Close/Open due 20.0 Software.MR · 13252953
- Cannot Boot Applications with Host Monitor Timeout Error.MR · 2217989, 2232651
- HOS Calibrations Make IIS Key Generation Fail.MR
- Loss of All Site Protocols after Save/Restore INFO due to 20.0 Software.MR · 13261149
- Part Numbers for the Filters used on the Rear of the SSM.MR
- Missing 48 V from PDU 48V power supply.MR · 2267431
- How to deselect GSPS (grey scale presentation state) series from appearing in browser with save state.MR
- How to deselect GSPS (grey scale presentation state) series from appearing in browser with save stateMR
- MRAPPS How to perform CartiGram imagingMR
- MRAPPS How to perform CartiGram imagingMR
- How to perform Graphic Rx ResetMR
- How to perform Graphic Rx ResetMR
- MRAPPS Where are interactive operator manuals.MR
- After LFC image Disk space is full.MR
- Where are interactive operator manuals.MR
- CTL adapter block is brokenMR
- MRAPPS How to perform Curved Reformat.MR
- MRAPPS How to perform Curved Reformat.MR
- Large Body Flex Coil cable is frayed.MR
- The Main Disconnect PDU Power Breaker Tripped due to Loss of Incoming Power.MR
- How do you view the Dicom header information of image files on an MR system.MR
- CWA Prescan Successful But Fails to Start Scan With EOS and RF Amp errors.MR · 2252716, 2252726
- Banding in 3DSPGR Saggital Images using any Multi-coil Coil.MR
- Need 12 in cable stub to complete Body Reflected Power Calibration (For 3.0T systems with LCC300 magnets).MR · 2254057, 50206
- Cannot find a FRU part number for the Patient Comfort Blower in HDe SM.MR · 2121199, 5323683
- The low efficiency of the cryo-cooler circuit has been identified.MAC00003 PDS Alarm Magnet Efficiency Issue detected a Magnet Performance Issue, Magnet Pressure increasing and Heater Duty Cycle at 0%…MR
- Cradle is making a screeching sound when it moves Due to The Cradle Connection pin worked itself out of position.Table is Making a Squeaking Noise When Going into Bore.Inspect the top and press the co…MR
- PC Will Not Boot.MR
- Probe calibrations are not to be performed on CRM systems the probepfix.dat file needs to contain only zero's.MR
- Gradient Hammer Test Fails Intermittently With No System Problem due to Known Problem in 20.0 SoftwareMR · 2267445, 2577258
- Magnet Monitor 3 was not placed into Service Mode.LCCI2 ALARM I2 WATERTEMP LIMIT.Explanation of the Magnet Monitor 3 Service Mode.Magnet Monitor 3.LCCI2 ALARMI2 WATERTEMP LIMIT.MR
- Duplicate Series Number with Internal Software and Recon Errors Logged due to Known Software Problem in 20.0 Software.MR · 2218546, 2219555
- Intermittently unable to scan with CAN errors 2252132 PDO Communication Failure and 2252133 SDO Communication Failure logged.due to CAN terminators and CAN cable.MR · 2252132, 2252133
- Several Series Were Missing and Never Reconstructed.MR · 2218537, 2272035
- unable to install vibrant flextrial optionMR
- Profile 4B LFC failed.MR
- After Every TPS Reset or Reset of PHPS CAN Node, Error 2262605 is Logged due to a Known Software Problem.MR · 2262605, 107521
- Who to Contact Regarding Magnetic Properties, Safety of Scanning Artificial Implants and Pregnancy in Patients.MR
- MGD downlaod fails due to defective inifiniband board.MR · 2249420
- The service key was expired.MR
- How to Determine Warning and Inhibit Limits For Patient Comfort Bore Temperature.MR
- TPS Reset Fails due to RRF Chassis Digital Power Supply Unable to Download or Reset The TPS MGD or ISE.MR · 2247157, 2247153
- CWA Exam is not in the Browser because it was deleted.MR
- Unable to Open MCQA Tool after Installing 15.0 M4 SP02 due to presence of old mc_qa_mcr directory (/usr/g/tools/mc_qa_tool/mc_qa_mcr).MR
- Defective Patient Handling Power Supply Module (PHPS).MR · 2262606
- Grafidy 3 failing with error "java.lang.exception" due to eight (8) channel or sixteen (16) channel option keys are not installed on the system due to not being structured on Gold Seal orders.MR
- What Should the SHeM Master Alarm be Set to?SHeM Master Alarm Settings.Magnet Monitor SHeM Advantech.SHeM Proprietary Software 2.3.7MR
- Compressor Not Functioning Due to insufficient power to the compressor.SIVI2 ALARM I2 - COMP NO 24 VOLTS.Facility power was restored and compressor was reset successfully.Magnet Monitor 3.SIVI2 ALARM…MR
- VRE configuration fails with the error Unknown board type found in ICN system Due to VRE.MR
- Defective SUN ICN caused VRE configuration failure.MR · 17047
- Link Needed for ACR (American College of Radiology) Web Site.MR
- Magnet Monitor 3 was not placed into Service Mode.LCC300I2 ALARM I2 HELEVEL LOW.Explanation of the Magnet Monitor 3 Service Mode.Magnet Monitor 3.LCC300I2 ALARM I2 HELEVEL LOW.MR
- Unable to Run LVShim after Loading 15.0 M4 SP02 Service Pack.MR · 2227938, 52973
- CWA Auto and Manual Prescan Fails.MR · 2223850, 10303
- CWA Unable to Scan with SGA Power Supply UnderVoltage Fault.MR · 2244855, 2244585
- ALARM I2 COMP NO 24 VOLTS due to Magnet Service Alarm Handling Procedure Failure.HFOI2 ALARM I2 COMP 2 NO 24 VOLTS.Use Magnet Monitor 3 Service Mode When Performing Magnet Service.Magnet Monitor 3.MR
- Patient alarm is not working due to failed Alarm Control Unit.MR
- CWA Cant Start A New Patient, screen is locked Due To Diagnostic Communications (DC) Error When Reading Socket Connection.MR · 2247814
- What is the Manufacturing Date to Enter on the ACR Accreditation Form to be Submitted to American College of Radiology.MR
- Unable to Load Applications Software During Load From Cold ProcedureMR
- VRE Configuration Failed Due to ICN Connections.MR
- Advance to scan is Required Multiple times to get Table to Scan Position Due to 40-1 reducer gear box.MR · 2224727
- Intermittent Warnings of high Patient Comfort Temperature Readings Due to Scan room air conditioning is not working.MR · 2225682
- The "36 GB HD replacement kit", p/n 5105101 for Octane II, is no longer available.MR · 5105101
- Failed Fan Control Board in 8645 Gradient Cabinet.MR · 2225703
- Extended TPS Reset Occurs on Most System Boot Sessions, Even When Not Required due to Software Problem in 20.0 and 20.1 Software.MR · 2223854
- Will Not Scan with Gradient Errors.MR · 2240265, 1177491864
- One of the Body Coil Bias boards reads open across the Pin Diode.MR · 2239991
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2249129
- eLicense invalid error when trying to install from GUI Due to Wrong HostID used when generating key.MR
- CWA How to Turn ON or OFF Application Guidance Which Flashes the Next Step in Patient Scanning.MR