Extended TPS Reset Occurs on Most System Boot Sessions, Even When Not Required due to Software Problem in 20.0 and 20.1…
Extended TPS Reset Occurs on Most System Boot Sessions, Even When Not Required due to Software Problem in 20.0 and 20.1 Software.
Symptom
Extended TPS Reset Occurs on Most System Boot Sessions, Even When Not Required See Long Description The system reports it is running an "Extended TPS Reset" on most boot up sessions of this system, even when, seemingly, it is not required. For example, when just restarting the system for unrelated reasons, and no power cycling of anything took place, we still see this message, which adds about two additional minutes to the reboot. Why is this happening and what can be done to avoid it? SPR # MRIhc45847. 2223854 ERROR: EM_mrNSP_VRE_RESET_PROLONGED Extended TPS Reset in progress (up to 8 minutes). Please be patient. Extended Error: One or more ICNs of the VRE might have been non-responsive during a TPS Reset. We therefore reboot all ICNs in an attempt to recover. The operator will experience longer TPS Reset times because of this.
Error message
2223854 Extended TPS Reset in progress (up to 8 minutes). Please be patient.-> See Long Description 2223854 ERROR: EM_mrNSP_VRE_RESET_PROLONGED Extended TPS Reset in progress (up to 8 minutes). Please be patient. Extended Error: One or more ICNs of the VRE might have been non-responsive during a TPS Reset. We therefore reboot all ICNs in an attempt to recover. The operator will experience longer TPS Reset times because of this.
Applies to
- Models
- Discovery, Optima
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.