After Every TPS Reset or Reset of PHPS CAN Node, Error 2262605 is Logged due to a Known Software Problem.
Symptom
After Every TPS Reset or Reset of PHPS CAN Node, Error 2262605 is Logged. Does This Indicate a Problem? These four errors are logged every time a TPS Reset or reset of the PHPS CAN node is done. Does this indicate a problem? Should we troubleshoot the system for these errors? Note: This is not a diagnostics error. Notice that the text "SCP:getPhpsVal" is included. This means the system is trying to query the PHPS motor amp data for HART. SPR # MRIhc45001. Tue Jul 28 23:34:12 2009 2262605 2 b2a NSP SCP:getPhpsVal 446 ^MException Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 A Failure was encountered uploading parameter 0x92 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.-> Tue Jul 28 23:34:12 2009 2262605 2 b2a NSP SCP:getPhpsVal 446 ^MException Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 A Failure was encountered uploading parameter 0x94 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.-> Tue Jul 28 23:34:12 2009 2262605 2 b2a NSP SCP:getPhpsVal 446 ^MException Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 A Failure was encountered uploading parameter 0x80 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.-> Tue Jul 28 23:34:12 2009 2262605 2 b2a NSP SCP:getPhpsVal 446 ^MException Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 A Failure was encountered uploading parameter 0x81 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.->
Error message
2262605 A Failure was encountered uploading parameter 0x20 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.-> 2262605 ghmr-ow0 diagCoord getPhpsVal 445 Diagnostic: PHPS CAN Iteration: 1 of 1 Action: 1 Task ID: 0x3d5c6c8 Time: 107521 Object: SCP A Failure was encountered uploading parameter 0x20 from the PHPS Motor Amplifier. Please try again or try resetting the Motor Amplifier through the Diagnostic Screen. Failure code is 26.->
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.