Duplicate Series Number with Internal Software and Recon Errors Logged due to Known Software Problem in 20.0 Software.
Symptom
Duplicate Series Number with Internal Software and Recon Errors Logged. See Long Description and Attachment A series number may be seen to be duplicated in the browser, and there are many internal software and recon errors logged. The user interface seems to hang briefly while this is happening. (See Attachment for two screen shots from the site, showing the duplicate series number in the browser). This is the operator's description of what happened from SPR # MRIhc43731 "System assigned same series number to two consecutive scans": System assigned same series number to two consecutive scans. Was in auto scan mode and scan was going on. Then I prescribed a new series save and click scan button. System UI was hanging for a while and gave an error msg. Then after the previous scan done, I scanned this series, and somehow I got two series with the same series number. Workflow User had auto scan on. Series #37 was scanning. User saved next series (#38) and it tried to download (either manually via manual attempt to scan, or from Auto Scan...I can't tell from logs). Once series #37 is done, user re-scans series #38 which, after scan is done, is numbered as #37, resulting in two series #37. These are the errors logged when this happened: Thu Jun 4 13:11:46 2009 2218546 4 lx-bay11b scn ../MsaScanMgr.m 4057 Could not exec son-of-recon process /usr/g/bin/recon1711. Thu Jun 4 13:11:46 2009 2218591 1 lx-bay11b scn ../MsaScanMgr.m 4058 Internal Software Error. Recon may not be complete Please see the log for details. Thu Jun 4 13:11:48 2009 2218548 4 lx-bay11b scn ../MsaScanMgr.m 4138 Son-of-Recon failure, exit status=65280. (The above sequence repeats many times) Thu Jun 4 13:33:50 2009 2219555 2 lx-bay11b scn ../SrxParScrCV.m 588 An internal software error occurred. (hundreds of the preceding error are logged, interspersed with the previous sequence of errors) Thu Jun 4 13:39:17 2009 2248336 4 lx-bay11b NSP SCP:sct_hct_reset_scan 708 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: zhangjam/gremre Coil: BODY Scan: 238/37 Host to SCT Interface Error. SCT received a new exam, series, or scan reset packet when scanning, prescanning, or preparing to scan. It therefore did not do the reset. Thu Jun 4 13:39:22 2009 2218592 4 lx-bay11b scn ../msaUtil.m 176 The MrMail send of reset to SCP timed out. Thu Jun 4 13:39:22 2009 2220147 1 lx-bay11b scn ../RxMgrDownload.m 860 Failed NEW SERIES level SCP reset Thu Jun 4 13:39:22 2009 2218630 4 lx-bay11b scn ../RxManagerIF.m 1165 The download of a prescribed series failed. Internal status code is 2220147. (the above sequence repeats, then the first sequence repeats again)
Error message
2218546 Could not exec son-of-recon process See Long Description 2218546 lx-bay11b scn ../MsaScanMgr.m 4057 Could not exec son-of-recon process /usr/g/bin/recon1711. 2219555 An internal software error occurred Tue Jul 18 14:42:23 2006 Error: 2219555 Host: lx-mr Process: scn File: SrxParam.m Line: 879 An internal software error occurred. 2218592 The MrMail send of reset to SCP timed out. See Long Description 2218592 lx-bay11b scn ../msaUtil.m 176 The MrMail send of reset to SCP timed out. 2220147 Failed NEW SERIES level SCP reset See Long Description 2220147 lx-bay11b scn ../RxMgrDownload.m 860 Failed NEW SERIES level SCP reset 2248336 Host to SCT Interface Error. SCT received a new exam, series, or scan reset packet when scanning, prescanning, or preparing to scan. It therefore did not do the reset. See Long Description 2248336 lx-bay11b NSP SCP:sct_hct_reset_scan 708 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: zhangjam/gremre Coil: BODY Scan: 238/37 Host to SCT Interface Error. SCT received a new exam, series, or scan reset packet when scanning, prescanning, or preparing to scan. It therefore did not do the reset 2218548 Son-of-Reco
Applies to
- Models
- Discovery
- Product
- Discovery MR750. Also called DVMR. This product is compatible with 3.0T 20.0, 20.1_IB1, IB2, 21.0 and DV22.0 software only
- Software
- 20.0 Also called DVMR. This software is compatible with 3.0T Signa MR750 systems only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- Corrupt Image Database.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID104279. System Software suddenly locked up.