Unable to Run LVShim after Loading 15.0 M4 SP02 Service Pack.
Symptom
Unable to Run LVShim after Loading 15.0 M4 SP02 Service Pack. Error is returned IMAGE READ ERROR See Long Description With 15.0 M4 SP2 software package installed When LVshim tool is launched Clicked on Scan Button Tool failed with error message popup as follows: " IMAGE READ ERROR ". [First Time] Also some errors were found in the /usr/g/service/log/gesys* message log. (see below for errors in log). Clicked on "Scan" button again and tool finished scanning with successful completion. Thu Oct 15 09:39:50 2009 2227938 4 mr-excite NSP MH_MBOX_VRE:ed_rdb_hdr_check 10 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: LVshim Coil: BODY Scan: 52973/1 The integer value for rdb_hdr_npasses in the header = 0, and is out of range. EN 298 Thu Oct 15 09:39:50 2009 2218527 1 mr-excite scn MsaScanOpsScrn.m 1037 Scanning has stopped. error please try again Hardware Details ------------------- Field Strength : 1.5T Gradient Coil Type : BRM Gradient Amplifier : HFD-S Software details ------------------ Software : ServicePack-02 , 15.0_M4_0910.a
Error message
2227938 The integer value for rdb_hdr_npasses in the header = 0, and is out of range. See Long Description 2227938 mr-excite NSP MH_MBOX_VRE:ed_rdb_hdr_check 10 Exception Class: Unknown Severity: Unknown Function: Recon: PSD: LVshim Coil: BODY Scan: 52973/1 The integer value for rdb_hdr_npasses in the header = 0, and is out of range. IMAGE READ ERROR See Long Description IMAGE READ ERROR This error appears in a popup window to the operator. It is not logged on the system. 2218527 Scanning has stopped. Error, please try again 2218527 lx-mr scn MsaScanOpsScrn.m 916 Scanning has stopped. error please try again
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.