Pular para o conteúdo principal
GE Healthcare · MRSignaExciteDiscoveryOptima225271622527262252738225271222542152252739

CWA Prescan Successful But Fails to Start Scan With EOS and RF Amp errors.

Symptom

Prescan Successful But Fails to Start Scan With EOS and RF Amp errors Prescan Successful But Fails to Start Scan With EOS and RF Amp errors.

Error message

2252716 Sequence playout error The SRF synchronizer FIFO became empty

2252726 SRF error. One or both DSP sequencers on the SRF board has indicated an error 2252726 SRF error. One or both DSP sequencers on the SRF board has indicated an error.

2252738 Sequencer DSP SSP_GRD_SEQ did not receive data from AGP prior to SSI causing a synchronizer EOS error. Error: 2252738 Host: mrs1_oc0 Process: NSP File: AGP:seq_drv.c Line: 1686 Sequencer DSP SSP_GRD_SEQ did not receive data from AGP prior to SSI causing a synchronizer EOS error. The AGP did not have enough time to download the sequencer updates. Please increase EOS-SSI time.

2252712 Sequence playout error. EOS from one or more sequence generators was not received prior to SSP EOS. Wed Sep 1 19:14:27 2004 Error: 2252712 Host: MRI1-OC0 Process: NSP File: AGP:agp_drv.c Line: 411 Sequence playout error. EOS from one or more sequence generators was not received prior to SSP EOS. Generator: Theta 2

2254215 SRFD2 RF Amplifier Gate Fault. Error: 2254215 SRFD2 RF Amplifier Gate Fault. RF Amplifier reports an unblank pulse width exceeding specification (100sec). Possible causes: the PSD is exceeding the limits of the system, or defective RF 

Applies to

Models
Signa, Excite, Discovery, Optima
Product
Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
Software
15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues