Does the MEDCAM Baseboard p/n 2292662-11 Require Terminators?The MEDCAM Baseboard p/n 2292662-11 Does Not Use Terminator…
Does the MEDCAM Baseboard p/n 2292662-11 Require Terminators?The MEDCAM Baseboard p/n 2292662-11 Does Not Use Terminators.HF OpenSpeed.
Symptom
Does the MEDCAM Baseboard p/n 2292662-11 Require Terminators? See Long Description FE is troubleshooting the MEDCAM on this HFO3 system, and has a MEDCAM baseboard part number 2292662-11. He is removing/adding CPU and memory daughterboards trying to isolate a defective daughterboard. But in so doing, he needs to know whether this baseboard needs the terminators to be applied that some other baseboards require when removing daughterboards. Looking at the sc1rea2 AP BOARD REPLACEMENT procedure document, on the latest revision OpenSpeed Service Methods (Direction 2250758-1 Rev 3 December 2008) there is no mention at all of this baseboard or terminators for any baseboard. (OpenSpeed Service Methods uses Rev. 0 of this document, in which there is no mention of this baseboard) How should he proceed? Does this MEDCAM Baseboard p/n 2292662-11 require the 2292662-6 terminators when daughterboards are removed? The same part is used on Signa LX. Looking at the equivalent procedure for Signa LX, in the Signa LX Service Methods (2160623-1, Rev. 23 June 2009) in the same document, there is a later revision, rev. 2. But in this document there is a discrepency. TABLE 1 MEDCAM COMPATIBILITY CHART shows the terminator is compatible with MEDCAM baseboard 2292662-11. And there are several other sections in this rev. 2 of the procedure dealing with the terminators, but no mention is made as to whether the 2292662-11 should be excluded from this requirement. But in the revision block on the last page of the rev 2 document, it states that the MEDCAM Basebord 2292662-11 is "a new part that no longer needs terminators per PQR 13165487". Also that revision of the replacement procedure is in the Signa LX Service Methods, not in the OpenSpeed Service Methods, and we are working on an OpenSpeed system. So the question remains, does the MEDCAM Basebord 2292662-11 require the terminators or not for OpenSpeed systems?
Applies to
- Models
- Signa
- Product
- HF OpenSpeed HFO1 HFO2 and HFO3 Only.
- Software
- HFO3
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.