GE MR — field troubleshooting
9,114 field-service issues · page 22 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Part Numbers for Paint used on the Cradle, Table and Magnet Enclosure.MR
- Scan Aborts with Error code 2257270 due to 3T Dual Body Hybrid.MR · 2257270, 53051
- Cannot scan Head coil with error 2252305 TR driver fault detected - open circuit Source of fault is Head T/R on Connector A Value 370 mA, limit 500 mA due to Preamp Boards.MR · 2252305
- What Catalog Numbers Provide Scan Tools Options for HDxT.MR
- Clarify. Can Annotation Font Size Be Changed ?MR
- MRIQ Severe noise artifacts Die to Integrated Multicoil Assy.MR
- UPM Body functional checks fail with peak power faults Due to RF Body Out of Calibration.MR · 2254782
- Missing Sixteen 16 Channel Option.Unable to Run MCQA Surface Coil SNR Tool.MR
- LX systems view the Dicom images from the workstation as an Ultrasound image, which is not a compatible image type for LX MR.No Workaround.MR · 11029, 11033
- Unable to Access the CD/DVD Drive due to the SCSI Tower was Powered Off During the Host Computer Software Load.MR
- ConnectPro HisRis Work list does not Update Due to Wrong date on the system.MR
- No ID Flt Displayed on the 8290 gradient SCA Board. profileMR · 2240271, 2240239
- How to Query Hard Drive Size Remotely or On Site.MR
- Probe calibrations have not been performed.MR
- Oscillatory Terms Do Not Converge in ECMT2 Calibration due to Burnt Component Within 6 TO 1 COAXIAL SWITCH part of ECMT2 Hardware Kit (2309800).MR
- CWA ID136466. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR
- Entries in the Patient Register Could Not be Removed due to Corrupted Entries In the /usr/g/protocols/patients/exam and series Directories Prevent Removal.MR · 2219663, 2219776
- Compressor Shut Off Due to Chiller Issue.svi2 alarm I2 Comp Off.Verify the water parameters are in spec and reset the shield cooler compressor.Magnet Monitor 3.1.56 SoftwareMR
- CWA ID136521. Scan Aborts with EOS Error.MR · 2218537, 2252713
- What is the Weight Limit of the Profile System Table?MR
- What is the Weight Limit for the Ovation Table?MR
- The SHeM and it's FRUs are no longer being stocked.Magnet Monitor SHeM Will Not Call Out.The SHeM and its FRUs are no longer valid parts and must be replaced by a Magnet Monitor 3.Magnet Monitor SHeM…MR
- Patient alarm is not working due to failed Alarm Control Unit.MR
- System gain calibration fails Due to UCERD Receiver.MR
- Unable to scan with multicoil TR driver faults due to a failed preamp protection module.MR · 2225553
- The Scan Stops Because the Application Did Not Receive a Trigger on Time due to Defective PAC.MR · 2226158
- 2260007 due to bad value in GUI for shim power supply.MR · 2260007
- Coils Will Not Stay Connected to the Legacy Multi Coil Port Due to the Multi coil Assembly.MR
- Scans Stop Intermittently With Error Code 2248008 Logged Due To Failed Remote RF DIF Board.MR · 2248008
- Pressure Heater Controller Software is Stuck.MAC00007 PDS Alarm Stuck Helium Pressure and Frequent Heater Cycling Condition.Resetting the Pressure Controller.Magnet Monitor 3.MAC00007 PDS Alarm Stuck…MR
- HFO Magnet Monitor 3 Connectivity Issue Has Been Identified.MAC00010 PDS Alarm Stale HFO Magnet Data, No Updates for Two Days.Cycle power to the Magnet Monitor 3 and hit "Call Insite".Magnet Monitor 3…MR
- No or Little Signal From Coil Elements 5 and 6 of 8CTL Coil due to Wrong Coil Name in Scan Prescription.MR
- CWA ID136797. Protocol PSD Download Fails.MR · 2248102, 10151
- GSC Was Not Detected Due to Gradient Switch Module Box.MR · 2244652
- The GP is reporting % Axis SGA Internal Wiring Fault and Internal Power Supply Undervoltage Due to ACGD SGA Control Board.MR · 2244599, 2244573
- Independent Vector Gating unavailable in scan application due to PAC Type is set incorrectly.MR · 2226158
- Power Monitor Faults Due to Patient weight was entered incorrectly.MR · 2254782
- Where Can I Find The Serial Number And Model Number For The MR System.MR
- Patient Table Loose Inside Mobile During Mobile Move.MR
- Table is Undocking as the Table is Raised Due to Loose Bolts on the Front of the Docking Assembly.MR
- Unable To Film.MR · 14029, 14019
- Grafidy 3 failing with "java.lang.exception" due to the Default Head Coil Selection of Head Port Linear T/R Tool Adapter.MR
- How do you modify the ProDiag schedule remotely.MR · 2218088
- What Systems can be Affected by the Conficker Worm.MR
- Environmental Sensors Not Reporting Due to Defective OneWire Hardware.MR · 2269251, 2269013
- Need a Software Vulnerability Report Addressed.MR
- 16 Channel Switch Diagnostics Fail Due to 16 Channel Switch. 16 Channel Switch Diagnostics FailMR · 2247387, 10509
- System ID Not Displayed in iCenter.MR
- Corrupt Protocol. scanning has stopped, error 2218527.MR · 2218527
- Head TR Driver faults Due to Loose head heliax connection at the penetration panel.MR · 2252305
- What is the Part Number for the Tape that the Cradle Rollers Ride On to Reduce Noise.MR
- Cannot Import Protocols in Proto Exchange Application Due to Password Request.MR
- Cradle Will Not Advance With Patient Loaded due to Cradle Release Block is Extended.MR
- Will Not Scan with Gradient Errors.MR · 2238414, 2238662
- Low Hydraulic Fluid Level.MR
- Patient comfort sensor trip Due to Gradient Cooling ProblemMR · 2248650
- MDS Configuration failed and RF Cabinet MDS peripheral response timeout due to defective SSM.MR · 2248679, 2248683
- Dot artifacts on 3T VH3 3T/940MR
- Probe calibrations are not to be performed on CRM systems the probepfix.dat file needs to contain only zero's.MR
- AP Errors Due to PPC Module on AP board.MR · 2228010, 2228016
- Need MSDS And Spill Response Due To Fluid Leak From Chiller Hose.What Is MSDS Information For BRM Coolant?.GE MSDS Numbers are USFS-44, WM-71.2138791MR
- Customer is repairing the chiller.LCC300 Alarm Water Flow Low.During Scheduled Chiller Maintenance FE should take ownership of ALL Magnet Alarms.Magnet Monitor SHeM Advantech.Software 2.3.7MR
- Restoring images from a Pioneer mod on a sony driveMR
- Unable to Reset TPS Due to Defective Ethernet Cable to ICN.MR · 2223859, 2249418
- The helium level is dropping greater than 5% over a 30 day period due to a possible helium leak.MAC00005 Proactive Magnet Performance Issue.MR
- Intemittent erorrs locked up system during scanning, needed system reboots to clear.MR · 2265211, 2265166
- What is the Part Number For TOD on Octane Computers or Dallas DS1687-5 NVRAM RTC Module.MR · 2291172
- MRIQ Signal Void in Propeller Images.MR
- Mouse not Working Due to SCIM.MR · 2248584, 1207812070
- Low Voltage on the High Voltage SSM Supply.MR · 2248599, 2249147
- CD/DVD Button Is Missing From the Browser Menu.MR
- MOD drive will not recognize media.MR · 10033
- CERD DIAGS ASC Static RAM Failure Due to CERD Digital Board.MR · 2236402
- Blank Monitor Due to DIMMs.MR
- Images Flipping Customer Letter.MR
- Low Voltage on the High Voltage SSM Supply.MR · 2225516
- Gradient Error 2244573 GP Reporting X Axis SGA Internal Wiring Fault Due to SGA Control Board.MR · 2244573, 2234211
- Patient Intercom Volume at Keyboard Much Too Loud Due To Defective SCIM.MR
- Light or Faint Corduroy Artifact Seen using All CoilsMR · 2248715
- Profile Application Software Fails to Boot.MR · 2219906, 200002352