GE MR — field troubleshooting
9,114 field-service issues · page 50 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- What is the Part Number for the Serial Cables Connected to the Termserver.MR
- Computer Freezes When Loading Applications Software During Load From Cold Procedure due to HP Host PCMR
- The Sumitomo compressor water flow and water temperature as individual vales are within specifications, But the combination of the 2 parameters is out of specifications.Rebuild flow sensor.5113506 Wat…MR
- Instrumentation Lead LEMO Connector is Loose Inside the Magnet.LCCI2 ALARM I2 HE LEVEL CBL OPEN.De-ice and Reseat Instrumentation Lead LEMO Connector-wqr.Magnet LCC.LCCI2 ALARM I2 HE LEVEL CBL OPEN.MR
- New MFO Blower motor trips the breaker.MR
- No ID Flt Displayed on the 8290 Gradient SCA Board.MR · 2240263
- CWA PDU in Stop Mode and TPS Download failure.MR · 2248602
- What is the correct part number for a Reflex 100 AP board?MR · 2325947
- CWA PDU in Stop Mode and TPS Download failureMR · 2248602, 2223817
- CWA Scanner Locked Due to Magnet Temperature Out of RangeMR · 2240982
- CWA Browser lists exams from last to first instead of first to last.MR
- Cannot find ETH2 following HP 9300 Replacement Due to Incorrect BIOS Setting for Ethernet Controller.MR
- The host can't communication with TCU due to a defective Aurora board in the Host CPU.MR
- Unable to Send Images to the PACS due incorrect network configurationMR
- 2267833 XGD reports no 420 V power due to XGD gradient power supply (XPS).MR · 2267833
- 2254054 RF Amplifier in low power state avoid MEMP FSE scans Due to SRFD2 Amplifier Falsely States it is in Low Power State.MR · 2254054
- System Hangs when Accessing hisris Work List Due to WLSystem.cfg FileMR · 200002356
- Appears the X and Y Coil Drive is swapped Error In DQA Calibration.MR
- Auto and Manual Prescan Fail when using the 8 Channel Body Array Coil.MR · 2224666, 2224725
- Known Software issue with 15M4B coding error.MR
- Fails TPS Reset when booting up to Applications or when Resetting TPS.MR · 2275708, 31260660
- Site Air Conditioning failureMR · 2248609, 2247127
- Mouse Will Not Move Unable to Login to Boot ComputerMR
- PDU was in Stop Mode.MR · 2248602
- CWA Scan Prohibited, Scanning Range Is Outside The Head Coil.MR
- Vertical band artifacts on LAVA series using the 8ch body array coil due to bent pins on connector 2417162.MR
- CWA Will Not Scan with Gradient Errors.MR · 2244647
- PSD download errors on any 8 channel coil Due to DRF BoardMR · 2248130
- Defective LCD monitor.MR
- How to Configure Scanner to send Study Instance UID from MWL Modality Worklist with Images to PACS.MR
- Loose connection on cables at SRI causing a checksum error in the downloaded SRI Code.MR · 2224829, 2249110
- Cannot Bring Up iLinq Browser.MR
- MCQA will not run on HNS coil.MR · 2218525, 2220066
- Unable to Transfer or FTP Core Files to Insite or OnLine Center due to Core File Permissions Too Restrictive.MR
- Coil Not Recognized and CoilID Light is Red.MR · 2261184
- How Can Customer Order Accessories When The Web Site Is Down.MR
- 5X mobile system will not boot up past the mobile site selection.MR
- Images Reconstructed but not Listed in the Browser, Only Displayed in Auto viewer.MR
- Browser Application buttons are out of order due to a space is in front of the Viewer name in the Application. edit the Button name in the Browser Application ManagementMR
- OrthoMRI Customer wants to purchase the Viewer Lite OptionMR
- Prescan failures due to defective Receiver board in the DCERD2.MR · 2252246, 2254782
- Error 2227915 caused by a defective AP board in the mGD chassis.MR · 2227915, 2224360
- Host Monitor Power Light Does Not Come On, No Video.MR
- XGA power suplly faults for 15, 2.5, and 5 volts Due to XGD Amplifier.MR · 2267943, 2267858
- Audio Trigger Volume bar in gating Control window not responding.MR · 5334885
- MRAPPS MRIQ Cine Phase contrast image is very noisy.MR · 2227826, 13055
- NV head coil superior Latch Will Not Close and Hardware on the Latch is Missing.MR
- What is the Correct Part Number for the RF Amp on Contour 1 through 3B?MR · 2123464, 2123465
- Where are the Unknown Coil Definitions Located in the Software.MR
- Unable to Scan with RF Air Temperature Faults Due To Customer Coolant Chiller.MR · 2268905
- DAQA test results show a jump in TG due to Split Head coil halves not seated correctly.MR
- Patient Warming Due to Coil.MR
- TPS Fails to Download with errors 2249431 2249432 Due to Infiniband BoardMR · 2249432
- 2269110 The TDM did not detect the 80 MHz clock reference at the TDM outputs to the RRX modules due to TDM module 5165957-51.MR · 2269110
- MRCustomerCall Image Quality Uneven FatSat Due to Metal on Patient.MR
- System intermittently locking up while scanning with Error 2224347 pixel header length field is inconsistent with recon supplied data due to defective IT transfer card ( PCI ADAPTER CARD IT HOST )MR · 2224347, 1110252196
- How to remotely check whether a System has Archive Node set to Auto for any Remote Host.MR
- SRI SCP Communication Error Due to SRI.MR · 2224829
- MRSPT severe failures only on Body FSE and GRE Stability Tests due to body preamp.MR
- Applications software will not load Guided Install during LFC due to INFO Media left in CD/DVD Drive in SCSI Tower.MR
- SMPTE Pattern Not Listed On The BrowserMR
- Gradient Processor Can Not Communicate With the Gradient Switch Box.MR · 2224666, 2244645
- Will not scan with error 2248217 Receiver calibration error.MR · 2248217, 2847174
- Heat Exchanger Cabinet (HEC) detected the coolant in the power electronics reservoir due to the Pump.MR · 2261726
- Slow and intermittent erratic Table movement Due to New style cradles and wheels are not strong enough to handle weight.MR
- Compressor Will Not Start Up.TWINSPEED Alarm Failed To Reset Compressor.SecondOpinion Part Number 2188440-2 Sumitomo CSW Series 4K and 10K Compressor wqr.Magnet Monitor SHeM Advantech 2.3.7MR
- What is the Part Number for the Mobile Gradient Heat Exchanger.MR
- What Options are Provided with HDxT Scan Tools Catalog M3340KG.MR
- Grafidy 3 failing with error "java.lang.exception".MR · 2277554
- HEC Coolant Reservoir Tank is Low Due to Stuck Reservoir Coolant Level SensorMR · 2261725
- OrthoMRI Unable to Restore Back Up after disk drive replacement and sw load.MR
- PDU was in Stop Mode.MR · 2224666
- Power Surge or Drop.MR
- PDU was in Stop Mode.MR · 2224666
- Gradient Overcurrent Fault occurs in 3-Plane FGRE-XL Localizer with ART imaging option in oblique plane due to Software Problem.MR · 2244848, 2244574
- What is part number for penetration filters.MR
- CWA Intermittent Image Reconstruction Failures.MR · 2232902
- Endbell foam and or gaskets are damaged and or misaligned.MR
- Supercon Shim supply currents not stable when attempting to shim.MR
- MR000110 PDS - HEC Alert - Facility Chiller Flow Issues Detected.MR