GE Healthcare · MROptima22757083126066022678492267425139512269076
Fails TPS Reset when booting up to Applications or when Resetting TPS.
Symptom
Intermittent SRPS shutdown during scanning
Error message
2275708 The RF Hub failed to recover CAN communication on wakeup. The RRX is reporting that RF Hub power is OK and clock is on. See Long Description Error: 2275708 Host: C-3TMRI2 Process: diagCoord File: RfHubCanHWO Line: 5792 Diagnostic: CFB Board Level Diagnostics Iteration: 1 of infinite Action: 1 Task ID: 0x2537bb0 Time: 31260660 Object: SCP Function: RF: RF Receive Communication Failure. The RF Hub failed to recover CAN communication on wakeup. The RRX is reporting that RF Hub power is OK and clock is on. Check RF Hub CAN cable connections.-> 2267849 The GMC is reporting a clock stop condition 2009 Error: 2267849 Host: LIBR-MR1 Process: NSP File: SCP:FspMac.cpp Line: 320 Exception Class: Unknown Severity: Unknown The GMC is reporting a clock stop condition Extended Error: Check that the system clock is plugged into the GMC. 2267425 No Clock Signal to IRF3 board. Error: 2267425 Host: WIMRMR2 Process: diagCoord File: Irf3.cpp Line: 1402 Task ID: 0x493f6b0 Time: 13951 Object: AGP Exception Class: Notification Function: Software/Firmware/Config: N/A No Clock Signal to IRF3 board. The IRF3 board did not detect a clock signal on the J8 fiber optic clock cable. This condition will
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA ID100513. Will Not Scan with Gradient Errors.
- CWA ID103384. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- CWA ID103582. Unable To Scan With Driver Module Errors.
- CWA ID104077. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.
- IApplication Software does not complete the boot process with TPS Download failure Due to Idle Overnight With Power On.
- CWA ID107471. Unable to Download or Reset The TPS MGD or ISE.