The Sumitomo compressor water flow and water temperature as individual vales are within specifications, But the combinat…
The Sumitomo compressor water flow and water temperature as individual vales are within specifications, But the combination of the 2 parameters is out of specifications.Rebuild flow sensor.5113506 Wat…
Symptom
MAC00017 PDS Alarm Compressor water supply fault caused by the combination of water flow and temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The combination of water flow and water temperature parameters is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow and water temperature as individual vales are with in specifications, But the combination of the 2 parameters is out of specifications. The OnWatch engine algorithm used the engineering specifications supplied by the manufacturer of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan. Refer to the latest appropriate service documentation here MR Service Documentation .
Error message
MAC00017 PDS Alarm Compressor water supply fault caused by the combination of water flow and temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The combination of water flow and water temperature parameters is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow and water temperature as individual vales are with in specifications, But the combination of the 2 parameters is out of specifications. The OnWatch engine algorithm used the engineering specifications supplied by the manufacturer of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan. Refer to the latest appropriate service documentation here MR Magnet Service Documentation
Applies to
- Product
- Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
- Software
- SHeM Proprietary Software 2.3.7. SHeM Proprietary Software 2.3.7 SHeM Proprietary Software 2.3.7.
- Component
- 5113506 Water Flow Meter Rebuild Kit. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. This information is Property of GE - For GE Service Personnel Only Disclosure to Third Parties Prohibited Subject: Spare Parts Announcement for Turbine Style Water Flow Meter Effectivity: All Magnet Monitor systems using the turbine style water flow meter part number 2333825. Announcement : Part number 5113506, Water Flow Meter Rebuild kit, is now available and orderable through GPO stock. The Illustration below shows the hardware contents of the kit. NOTE: The Illustration did not successfully transfer to the Long Description. See the Attachment for the FULL SMILe and use the following Link to view Service Note 67097 . IMPORTANT! Make sure the water flow meter is installed in the correct orientation. Details on performance issues relating to mounting orientation and instructions on how to replace the internal components are detailed in Service Note 67097. A copy of the Service Note is attached for your convenience. Paul Senski LSI - MR Service Engineering (262) 521-60 52 GE Medical Systems SMILe's and Service Notes are copyright (c) to General Electric Company Inc with all rights reserved. SMILe's and Service Notes issued by GE Medical Systems are proprietary to GE Medical Systems. Disclosure to persons not employed by GE Medical Systems or not in possession of a Advanced Service Agreement with GE Medical Systems is prohibited.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.