GE MR — field troubleshooting
9,114 field-service issues · page 41 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Maxwell Term Artifacts Due to Scanning with Flow Comp and Swap Phase and Frequency.MR · 15000, 638761410
- Where are the wlsErrors.log hisris Modality Worklist MWL Error Log, Config Files, and Worklists Kept on Discovery MR450 and MR750.MR
- CWA Applications Software Will Not Boot.MR · 2252246
- Annefact Star Artifact Root Cause.MR
- MRIQ Shading in Images Due to the Receive Coil in use.MR · 2224709
- Low Voltage on the High Voltage SSM Supply.MR · 2225516, 2225540
- Power monitor fault due to SSM.MR · 2225738, 2225739
- MRCustomerCall Image Quality Low Signal to Noise Ratio (SNR) Due To Coil Cable.MR · 2224725
- Exam is not in the Browser because it was deleted.MR
- Blue Handle Broken Off the Foot End of the Table.MR
- Low Voltage on the High Voltage SSM Supply.MR · 2249147, 2224666
- Star Artifact Peripheral signals are generated outside the desired field of viewMR
- Unable to Select New Patient, Patient Register button for New Pt Is Grayed Out, due to corrupt config files.MR · 2248681, 2223836
- MRAPPS How do you access operator manuals from within the system.MR
- MRAPPS Where can I find information on non-GE cardiac anatomy.MR
- MRAPPS Cine Phase contrast image is very noisy.MR · 2227826, 13055
- GASM V BUS -HI Monitoring Error.MR · 2238746
- Magnet Monitor devices Alarming for Coldhead Temperatures because the Checkout was not completed properly.hfo_orgi2 alarm I2 - ShieldTemp Low.Magnet Monitor Devices Alarming For Coldhead Temperatures…MR
- Grafidy does not converge on all axes.MR · 2234211
- How to check RRI Z2 Shim Power Supply Communication.MR · 60642
- 159027 How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 and MR750 Systems.MR
- E-scanner, Small button on back left of monitor was off.MR
- How to Remotely Determine Whether System is a 16 or 32 Channel System.MR
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2267431, 200002372
- System Hangs During Image Reconstruction with Processor Exception Bus Errors and not enough memory available to start acquisition errors due to AP memoryMR · 2218527
- Signal loss is due to a failed coil element.MR
- Defective SGA AmplifierMR · 2244579
- Erbtec RF Amplifier 85 faults When Scanning with Extremity Coil Due to Damaged CoilMR · 2225664
- Magnet Monitor Satellite Serial Communication Failure due to Defective SHeM.MR
- Site is Requesting The Serial Number for HP Workstation.MR
- SecondOpinion Multicoil Assembly Excite3 5115143.MR · 5115143
- The Main Disconnect Panel Auto Restart circuit Battery is not properly charging.MR
- Application does not Boot up with VRE Errors due to ICN.Can Not Boot Application Software With VRE Errors.SecondOpinion Image Compute Node 5127452.Signa HDxT.15.0.2223817 Exception Class.MR · 2223859, 2223880
- SecondOpinion 2413107-1, 3T CTL II FRUMR · 2413107
- Unable to Load Applications Software due to SCSI Interface on HP xw8000 Host PC.MR
- Power Surge or Drop.siii2 alarm I2 Comp Off.Reset the Shield Cooler or Cold head Compressor.Magnet Monitor 3.siii2 alarm I2 Comp Off.MR
- Mouse Cursor becomes a Large Cross then Hangs Due to HP Linux PC.MR · 200002352
- Signal Too Small Due to SRFD2.MR · 2224725, 2224666
- Low SNR due to high noise caused by poor RF door seals.MR · 2224725
- Leaking coolant around pump assembly in Gradient Heat Exchanger.MR
- Patient Comfort Bore Fan Making Unusual Noises.MR
- eLicense Key Download Failed due to a Software Problem Between eLicense and ISD 4.0.MR
- The Scan Stops Because the Application Did Not Receive a Trigger on Time due to Defective PAC.ECG Cardiac Gating and PPG Pulse Gating lose their Waveform as Soon as Scan StartsMR · 2218537
- Error 2252306 due to shorted RF transmit cable.MR · 2252306
- After upgrade to 15.0 M4 LVshim is now way out Large Compensation numbers.MR
- How to Determine If Site Image Database Reset Is Still Running, or CompletedMR
- Signal Too Small Due to Banana plug on the coil port is loose.MR · 2224666
- Will Not Scan with Gradient Amplifier % Axis Current Distortion Fault due to BRM-DMR · 2245053, 59528
- How to Properly Set the Jumpers on the CDROM drive.MR
- CWA Unable to Download or Reset The TPS MGD or ISE.MR · 2249418
- SAR Limits for .35T Ovation in W/kg.MR
- CWA Application Software does not complete the boot process with TPS Download failure.MR · 2277672, 1537357
- 16 channel switch diags fail with 2247385 due to a design change in diode biasing made to recently released preamps with part number 5400044.MR · 2247385
- Getting loud feedback or squealing on the SCIM speaker due to SCIM.MR
- Unable to scan with RF errors due to RFI.MR · 2248816
- MRIQ Shading or Metal Artifact Due to Mascara on the Inside of the Coil.MR
- TPS or MGD Download Fails Due Defective Gradient Processor 2 Module (GP2).MR · 2225699, 2225704
- MRSPT System Locks Up during SPT Scan Due to Defective IPG.MR · 2223847, 2223831
- Alignment Lights, Patient Blower and Bore Light Do Not Function Due To SSM.MR · 2224733, 2225337
- Prescan Fails Due To SRFD2 RF Amplifier Peak Power Fault.MR · 2254212
- Does the New WideBore Magnet Need a Special Magnet Monitor?MR
- Images are Grainy Noisy Due to Multi Coil Assembly.MR · 2224725
- CWA HP Linux Workstation Fails To Boot To The Login Screen.MR
- lcc300 alarm System stuck in Fill Mode.Had customer turn the Fill Key Switch on the SHeM out of fill mode.Magnet Monitor SHeM Advantech.lcc300 alarm System stuck in Fill Mode.MR
- Severe noise due to 21132801.5T DYNAMIC DISABLE board.MR · 2224713
- Legacy multi-coil is not recognized and Coil Presence Failed Due to Coil Must be Manually Selcted From Drop Down List.MR
- Unable to Write Images to DVD Media.MR · 2243501
- The Leybold Coolpak CP 4000 Coldhead Compressor interface cable is not correct.SXI2 ALARM I2 COMP NO 24 VOLTS.Leybold RW4000 Compressor Interface Cable for use with Magnet Monitor devices.Magnet Monit…MR
- CWA Auto and Manual Prescan Fails.MR · 2224666
- CWA Accidental Push of E-stop Button.MR · 2267825
- 2252302 Multicoil Bias Fault Due to Coil.MR · 2252302
- CWA Unable to Scan with Power Monitor Faults due to Split Head Coil Halves Were Not Completely Closed Together.MR · 2254782, 2224589
- MRSPT SPT crashes with error 2227071 Due to Octane PCI bit 3 card.MR · 2219712, 2218630
- 8 Channel Coils are Not Recognized by Coil ID Due to Coil receptacle A not allowing coils to be plugged in properly. 8 Channel Coils are Not Recognized by coil id.MR
- CWA Prescan Successful But Fails to Start Scan With EOS and RF Amp errors.MR · 2252726, 2252738
- Error 2247383 The signal's channel-to-channel variance exceeded the specification for channel Due to UTNS3. 16 Channel Switch Diagnostics Fail.MR · 2247383, 685114
- ICN disk error 2277662 in log Due To ICN.MR · 2277662
- Detected 0 infiniband cables on the ICNs but 2 were expected Due to Sun Infiniband incorrectly cabled.MR
- CWA MOD Drive will Not Insert or Load MOD.MR
- Patient alarm is not working due to Alarm Control Unit.MR