GE MR — field troubleshooting
9,114 field-service issues · page 9 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Unable to Print Due to No Communication Between the DASM and Camera.MR
- CWA ID114702. Protocol PSD Download Fails.MR · 2217489
- Magnet Monitor lost call out function during a power failure due to Main Disconnect Panel Auto restart circuit failure.MR
- OrthoMRI Gradient amplifier inducing noise into gradient coil.OrthoMRI A crackling or hissing sound is coming from the magnet.OrthoMRI Replaced the gradient amplifier.OrthoMRI Escan XQ.MR
- Burn Smell coming from RF Cabinet.MR
- 8Channel 8CTL No or Low Signal due to Multicoil Assembly.MR · 2224725
- Octane Computer Intermittently Locks Up.MR
- Unable to Scan due to Error Code 2267906 due to One of the Leak Sensor Strips in Base of PGR Cabinet was Disconnected.MR · 2267906
- High Vessel Pressure Due to Cold Head efficiency. hfo_orgi2 alarm I2 HePressure Limit.MR
- 241605 PPBM Output Voltage (VRAIL) Monitoring Error Due to PPBM.MR · 2241605, 1083061534
- Elevated vessel pressure due to degraded cold head performance. hfoi2 HePressure Limit.MR
- WaterTemp Low Due to problems with Water Flow Sensor Assembly.MR
- ProfileHD Magnet Shimming Cables are not a FRU.MR · 5196273, 5110815
- Unable to Boot Applications Software with Host Monitor Faults Due to Corrupt Image Database.MR · 200002352, 200002372
- OrthoMRI What is the part number for the table extension wheel?MR
- Cannot Access Media After Replacing CD Drive with New DVD Due to Termination Jumper Missing on DVD.MR · 10033
- How to Determine if Functool is installed.MR
- OrthoMRI Blown main fuse.MR
- SHeM Software Versions prior to 2.3.2 are NOT capable of being remotely updated.MR
- Customer Network Speed does not allow Magnet Monitor 3 communication.MR
- CWA ID 115202 Can Not Scan.MR · 2233312
- OrthoMRI DSPM Troubleshooting.OrthoMRI Error Starting DSP code.OrthoMRI Replace the DSPM board.OrthoMRI E-Scan (Windows) NE.OrthoMRI Error starting DSP Code 43MR
- What is the normal condition for the status LED's on the Sumitomo F-50H Compressor.MR
- OrthoMRI The Power switch lamp is broken.MR
- CWA ID115234. Can Not ScanMR · 2219549, 2218630
- CWA ID115238. Scan Aborts with MDS Link Error.MR · 2225693, 2225704
- MRIQ Collapsed Image Bright White Line Down or Across Middle of The Image due to Site Power Fluctuations.MR · 2244847
- Cradle Will Move in Briefly then Stop Due to Table Plunger was preventing the table from advancing.MR
- What is the part number for the checkINFO software CD and how can it be ordered?MR
- OrthoMRI UPS is not working properly.MR
- Satcomm Modem is disabled or "zapped".MR
- OrthoMRI Customer accidently deleted the protocol.MR
- OrthoMRI Can we order patient positioning pads on the iProcurement web site.MR
- OrthoMRI Coil 1 is failing SNR test during troubleshooting.MR
- OrthoMRI The 4th Channel gradient cables are reversed.MR
- Customer is unable to view any SPT Files.MR
- Location of OnLine Operator Manuals for Hino/Beijing MR Scanners.MR
- Main Display is on the Waveform Monitor Due to Wrong Cable.MR
- Retrieve Historical SHeM Data.MR
- What is the Vacuum Specification for the Universal Fill Line Kit.MR
- Parking Current Calculator for Conquest (CX) MagnetMR
- Checking to see if a Magnet Monitor Satellite modem is Provisioned or turned on with Orbcomm.MR
- How Does The Helium Circuit of a Magnet Work.MR
- Will Not Scan With Gradient Errors Due To GRAM Module.MR · 2238686
- The Scan Stops Because the Application Did Not Receive a Trigger on Time due to Defective PAC.MR
- Shading in Lumbar Images Due to Auto-N-Coil, CV24 is 1.MR · 15000, 638915050
- Profile 5 shoulder coil failing autoprescan with open circuit bias faults.MR · 2262725, 2224666
- The service key was expired.MR
- 2225686 The bore temperature reading is low due to Lytron chiller set point too low.MR · 2225686
- CWA ID115671. SecondOpinion 1.5T HD NV Array Medrad with cable 5117092-2.MR · 5117092
- MRIQ All Signal in a Narrow Band of Image or Partially Collapsed Gradient Due to GP3.MR
- Scan Pause and Bright Zipper or Band in Images caused by TWIN GRAD SWITCH BOX.MR · 2244655
- 2232902 Processor Exception Frame, Bus Error Due to UCERD Digital Board.MR · 2232902
- Unable to archive Due to svst File.MR · 10191, 10180
- OrthoMRI Shoulder coil 1 will not tune without errors.MR
- MRIQ Grainy low SNR Quad Head Coil Images with Normal Prescan Values due to Quick Disconnect box.MR
- Scan Pauses with Gradient Errors Due to STIF board.MR · 2250083
- What are the Differences Between Profile 4B and Profile High SR.MR
- Magnet Monitor 3 is sending only partial data to Questra.MR
- Corrupt Image Database.MR · 2218527, 2217995
- What are the Magnet Monitor 3 Alarm Fault Codes.MR
- Z-Axis Mini GRAM FailureMR · 2241520, 2241528
- PSD Download fails due to CAT5 cable from Network switch in system cabinet to the Host PC NIC card.MR · 2248355, 2219712
- LX system won't scan due to 8645 Power Module PPBM errors on all 3 Gradient axis.MR · 2238450, 2238451
- Table Longitudinal Drive Problems Due to Gear Reducer 40 to 1 Gear Box.MR
- Magnet Monitor 3 is unable to connect to the Questra, Insite2 database.MR
- CWA ID116004. Intermittent ROTMI Calculation Errors Due to too broad of a detection for radial prescriptions.MR · 2218725, 2218624
- CWA ID116009. Mouse Stops Working During A Scan.MR · 2247819
- Mouse Cursor Movement Erratic Due to Mouse.MR
- What is the file format for the Auto Voice.MR
- 2225536 Dynamic disable and T/R driver board error Due to Quad Extremity Coil.MR · 2225536
- Low water flow alarm due to Water Flow and Temperature Assembly Failure.MR
- NEC 1990 SXi LCD Gamma Table Pop-up window does not appear after loading the patch.MR
- MultiCoil Receive Test (MCR) Fails with Low SNR.MR
- Intermittently Unable to Download PSDs Due to Network Switch (Ethernet Hub) in the System Cabinet.MR · 2218630, 2218501
- System is slow after FMI HD 12.0M5a 60746 with 8200 HP Due to 2 Video Cards.MR · 60746
- Unable to run MCR2 functional checks due to using a MCR3 tool on a HDx upgrade. 1.5T/3.0T MCR2 Service Tool No Longer Ships with HD Forward Production or UpgradesMR
- The SRP was not issuing the TTL logic control signal to the Preamp which enables the RX Coil Protection Circuit.MR · 2240010
- What Are The Gradient Power And Rise Time and Slew Rate RatingsMR
- How do you view the Dicom header information of image files on an MR system.MR