Low water flow alarm due to Water Flow and Temperature Assembly Failure.

Symptom

Erratic and low readings with the Turbine style water Flow Temp sensor. Erratic and low readings with the Turbine style water Flow/Temp sensor.

Error message

LCCI2 ALARM I2 WATERFLOW LOW. LCCI2 ALARM I2 WATERFLOW LOW, the Water Flow is lower than the low alarm limit setting on the Magnet Monitor 3.

Applies to

Product
Magnet Monitor 3. Magnet Monitor 3 Magnet Monitor 3
Software
Magnet Monitor 3 Revision 1.56. Magnet Monitor 3 revision 1.56, distributed to sites with Connectivity automatically post FMI 60755 release on 6/23/2008. See Long Description for Fixes and Notes. Magnet Monitor 3 Revision 1.56 Software (formerly known as 1.55). Fixes New magnet type selection page with menus for both compressors. New remote commands to change the compressor selections. New uploaded properties to show the current compressor selections. A fix to the satellite interface so MM3 doesn't lose the sat link if it gets a malformed entitlement message. Changed configuration files so ABM and BOM magnets with DT500 sensors use the correct lookup tables. Disabled alarms actually won't generate alarms. The net mask no longer has to be entered with extra zeros (i.e. - 255.0.0.0 is now good enough instead of 255.000.000.000). The "Show Digital IO" web page shows all compressor types correctly - no more messages saying that Leybolds are inverted. New alarm limits for ABM and BOM for 2nd_stage_shield (is now 10K to 25K, was previously 3.5K to 10K). Changed Master Interval to 720 minutes for LCC and Non-Zero boil off magnets and 360 minutes for HFOs to reduce dispatch volume. NOTES •Software will be downloaded to all communicating sites except satellite modems. •Currently there is no CD that is orderable as a FRU for sites that do not have communication or have a satellite modem so that the software can be manually updated.
Component
5113506 Water Flow Meter Rebuild Kit. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. SMILe 05/12/2005 "Spare Parts Announcement for Turbine Style Water Flow Meter". See Attachment and Long Description. This information is Property of GE - For GE Service Personnel Only Disclosure to Third Parties Prohibited Subject: Spare Parts Announcement for Turbine Style Water Flow Meter Effectivity: All Magnet Monitor systems using the turbine style water flow meter part number 2333825. Announcement : Part number 5113506, Water Flow Meter Rebuild kit, is now available and orderable through GPO stock. The Illustration below shows the hardware contents of the kit. NOTE: The Illustration did not successfully transfer to the Long Description. See the Attachment for the FULL SMILe and use the following Link to view Service Note 67097 . IMPORTANT! Make sure the water flow meter is installed in the correct orientation. Details on performance issues relating to mounting orientation and instructions on how to replace the internal components are detailed in Service Note 67097. A copy of the Service Note is attached for your convenience. Paul Senski LSI - MR Service Engineering (262) 521-60 52 GE Medical Systems SMILe's and Service Notes are copyright (c) to General Electric Company Inc with all rights reserved. SMILe's and Service Notes issued by GE Medical Systems are proprietary to GE Medical Systems. Disclosure to persons not employed by GE Medical Systems or not in possession of a Advanced Service Agreement with GE Medical Systems is prohibited.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues