GE MR — field troubleshooting
9,114 field-service issues · page 113 of 114
Symptom, error message and equipment context for each GE MR issue are public — the full cause analysis and step-by-step resolution are available to FSELIB subscribers.
- Need the part number of the SHeM Serial Cable.MR
- eLicense Unable to update the Host ID, troubleshooting steps.MR
- Will Not Scan with Gradient Errors.MR · 2250080
- Images Not Displayed In The Viewer Or The Browser Due To Corrupt Software.MR · 2224356, 2227972
- Table Carriage is moving slow Due to Clutch is too tight.MR
- How to Identify ICN Number on Multi-ICN SystemMR
- No annotation on IVI images(pjn) transferred to 3rd party PACS Due to the PACS does not know how to handle the Dicom tag (0x0008,0x0064).MR
- Unable to Complete TR Dynamic Disable Calibration with Driver Module Errors Due to the Driver Module.MR · 2252359, 2252358
- Host Monitor Timeout Error Due to Ethernet Cable on NIC was SwitchedMR · 2223817
- Is it Possible to Remotely Remove Purchased Option Keys.MR
- Unable to Scan with SGA Power Supply UnderVoltage Fault due to PS-Lite2 Control Board.MR · 2244607, 2244605
- SRI Power Cable Run # 773 Connection Loose at Rear of SSM MR1-A7-J35.MR · 2224733
- Bug in Software.MR · 13166914
- CoilID Not Working for Any Coil due to SRI-3 Assembly.MR · 2261176
- What is the part number for the new Turbine style waterflow assy.MR
- Gradient Error 2244573 GP Reporting X Axis SGA Internal Wiring Fault Due to SGA Control Board.MR · 2248016, 32754
- Corrupt Image Database.MR
- Auto Prescan failed, RF Amplifier is not ready.MR · 2254215
- Coil Not Upgraded With Coil ID Box.MR · 2262133
- Cannot Scan With Coil Plugged into LPCA Upper Port.MR · 2224862, 2220008
- SMPTE Pattern Not Listed On The Browser.MR
- How Do I Setup the Table Home Sensor Flag Position.MR
- Coil Not Recognized Due To Bent Pins In Quick Disconnect Box.MR · 2258107
- What is the Part number for the ATD Auto Tunning Device.MR
- Illegal Character in the Destination Hostname (space).MR · 11004, 11026
- Mechanical installers had run Infiniband cables to left port on ICNs (port 2).MR · 2249420, 106634
- The Low Level Magnet Drift Z2 Shim Supply Has Reached the Extreme Lower End of its Range and Cannot Find Procedure to Re Zero it.MR · 13167902, 60642
- W/L setting must be standardized to enable printer setup.MR
- CWA ID97626. Computer Will Not Boot with the message on the screen that says Do Not Interact With System.MR · 2223817
- Defective Analogic RF amplifier.MR · 2225744, 2225590
- How to locate the Satellite Modem Serial number (ST250XXXXXXX).MR
- Magnet Monitor Alarm for high water temperature.MR
- hfo alarm He 2 upper Low.MR
- Low Voltage on the High Voltage SSM Supply.MR · 2225526, 2225516
- Need the Gauss Line Map for a 1.0 T GE Magnet.MR
- HFOi2 alarm for the Recondensor Si410 Cable.MR
- Protocolup Command Is Needed Due To Transferring Protocols From One System to Another.MR
- can link is interrupted due to GP3 module failure.system hangs intermitently.replace GP3 Module PNMR · 2252243
- HDe TPS Reset Fails Due to VRE Configuration.MR · 3000004, 2249420
- 2252305TR Driver Fault Detected Open Circuit Source of Fault is Body TR.MR · 2252305
- Cold Reset Message Occurs During Reboot due to Three Cables Not Connected to APS Board.MR · 2249320, 1081934830
- Unable to Obtain Cable Needed for Customer Turnover.MR
- ACGD Gradient Hardware Limitation When Running Double Oblique FIESTA Scans.MR · 2244592
- How does the Customer save Raw Data.MR
- Will Not Scan in Body Transmit Mode Due to Hybrid Splitter.MR · 2252305
- Intermittent Image Reconstruction Failures Due to AP BoardMR · 2228010, 2228016
- How Much ACR Assistance Does GE Provide Free To Contract Customers.MR
- Cannot Bring Up iLinq Browser Due to Closing Ilinq Window by Clicking on the "x" in upper Left.MR
- Unable to adjust Window or Level on Images.MR · 2236699
- Intermittent warnings of high patient comfort temperature readings Due to Low Coolant LevelMR · 2225682
- Unable to Load Solaris Operating System on SPARC Ultra2 Computer.MR
- Operator error when selecting prescriptions, needed to instruct on proper use of mouse, with graphic prescription.MR
- CWA ID98111. Image Database does not Respond or Update.MR · 2219864
- Auto Prescan Never Ends Due To Bad STIF Bd in MGD Chassis.MR
- Computer Pauses Before Operating System Boot With Error Message "expansion memory initialization error, PCI mass storage controller in pci slot 03" due to HP xw8000 Computer.MR
- Linux HP Computer Intermitent Crash and Monitor is Blank Due to GOC Fan.MR
- Unable to Scan either Body or Multicoil Modes with 3T Body Hybrid Errors Due to System Cables Under Water. 3T Excite HDx 14.0.MR · 2252363
- Applications will not Initialize with PM Due Pop Up Message Due to PM Not Scheduled.MR · 2220066, 2218670
- Browser Viewer Application Invocation String Had Upper Case V instead of Lower Case v for viewer Browser Viewer Does Not Open When Series or Image Double-Clicked in Browser, nor When Viewer Button Sel…MR
- Corrupt Image Database.MR
- OrthoMRI Broken and missing RF fingers on the door of the pavilion.OrthoMRI Getting RF streaks on all images.OrthoMRI Replaced damaged RF finger strips.OrthoMRI Escan (Unix Digital)OrthoMRI Warning, s…MR
- OrthoMRI corrupt software.OrthoMRI Unable to run exams, OPI.exe errors.OrthoMRI replaced the hard drive.OrthoMRI Cscan.OrthoMRI error message OPI.exe errorMR
- OrthoMRI Wheels on the door are broken and will not moveMR
- OrthoMRI RF shield boots are worn and corrodedMR
- OrthoMRI Corrupted calibration file.OrthoMRI Ghosting on multislice scans.OrthoMRI Restored the .rec file back up files.OrthoMRI EscanNE.MR
- Environmental Sensor (temperature and humidity) not working.MR · 13091170
- CWA ID98363. No Power To The PDU on a Mobile after a power outage.MR
- OrthoMRI Daylight Savings Time changeMR
- Unable to scan with Power Monitor Faults due to HN Bulkhead Connector (Body Heliax Feed Through Connector).MR · 2225737, 2225738
- Is there documentation on the Leybold or Balzer to Sumitomo Coldhead upgrade.MR
- OrthoMRI SCSI bus not working due to external CD writer.MR
- Scan room Door Inflatable Seal is Not Working.MR
- Looking for further information on installation and orientation of Turbine Style Water Flow / Temperature sensor assembly.MR
- Will Not Scan With RF Errors due to the Processor Board.MR · 2225612
- Grafidy 3 Fails to Converge Long Time Constants due to crossed cables.MR
- CWA ID98607. Unable to scan with DRF Over Range Errors.MR · 2248108
- calculate pressure drops through sumitomo compressorMR
- OrthoMRI There is no selection in the software for the gap value to be placed on the films.OrthoMRI Need to put the slice gap on the images.OrthoMRI How to calculate the gap.OrthoMRI EscanNE.MR
- OrthoMRI corrupted rec files.OrthoMRI Ghosting on phantom and patient images.OrthoMRI Restored the back up rec files.OrthoMRI EscanNE.MR
- OrthoMRI Coil is still loose after closing locking handle.OrthoMRI Coil locking device is broken.OrthoMRI Replaced the coil locking mechanismMR