Cannot Scan With Coil Plugged into LPCA Upper Port.
Symptom
Cannot Scan With Coil Plugged into LPCA Upper Port. Coil ID Does Not See Any Coil in LPCA Upper Port See Long Description This is a research site that builds and uses their own coils. This coil ID failure began right after the customer had plugged in one of their research coils that they had built. The Coil ID LED stays dark and does not recognize any coil plugged into the LPCA's upper port. However they can continue to scan with any multicoil plugged into the LPCA's lower port. The error message shown below is logged on system reboot: Fri Feb 15 09:30:40 2008 2224862 2 CB-3TMR NSP SCP:SRI 575 Coil ID Warning. Information returned from the coil indicates the coil does not contain a valid ID. An older coil that has not been upgraded with coil ID would fail in this way. If this is instead a newer coil, the coil may be programmed incorrectly. The error message shown below is logged when trying to scan with a coil plugged into the LPCA's upper port: Fri Feb 15 09:40:16 2008 2220008 5 CB-3TMR scn RxMgrDownload.m 2148 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. Upper coil connect status:0, Upper coil code:Null, Lower coil connect status:1, Lower coil code:Null
Error message
2224862 Information returned from the coil indicates the coil does not contain a valid ID. An older coil that has not been upgraded with coil ID would fail in this way. Thu Feb 12 15:01:10 2004 Error: 2224862 Host: lxmr Process: NSP File: SCP:SRI Line: 575 Coil ID Warning. Information returned from the coil indicates the coil does not contain a valid ID. An older coil that has not been upgraded with coil ID would fail in this way. If this is instead a newer coil, the coil may be programmed incorrectly. 2220008 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. Upper coil connect status:0, Upper coil code:Null, Lower coil connect status:1, Lower coil code:Null 2220008 CB-3TMR scn RxMgrDownload.m 2148 RF coil connection failure detected, reconnect coil and if problem persists contact GE Service. Upper coil connect status:0, Upper coil code:Null, Lower coil connect status:1, Lower coil code:Null
Applies to
- Models
- Excite
- Product
- 3T Excite G3 Software ONLY
- Software
- E2 3T Eclipse
- Component
- 2362995-2 Eight 8 Channel Switch
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.