Unable to Complete TR Dynamic Disable Calibration with Driver Module Errors Due to the Driver Module.
Symptom
Unable to Complete TR Dynamic Disable Calibration with Driver Module Errors See Long Description System is a new 3T Excite HDx system being installed. The FE is unable to complete the TR Dynamic Disable Calibration due to the Driver Module errors shown below, which are logged on every attempt. Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150872 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD1 (Dynamic Disable Boards at Front of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150873 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD2 (Dynamic Disable Boards at Front of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD3 (Dynamic Disable Boards at Back of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD4 (Dynamic Disable Boards at Back of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive inside the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again.->
Error message
2252359 Driver Module has detected a potential open circuit in the DD Direct Drive inside the Body Hybrid Assembly path Error: 2252359 T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive ins ide the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again.-> Error: 2252359 T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive inside the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again. 2252358 on 11.0 and OPENMR4 is changing to 2252359 on 11.1 and OPENMR4a sw. 2252359 has been used on 12.0, 14.0, HDe 14.0 E2, G3, and OPENMR5 sw.
Applies to
- Models
- Excite
- Product
- 3T Excite HDx 14.0 Software. The software that this solution is tied to is indicated by the Software concept below.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Component
- SecondOpinion Excite HD & HDx Driver Module 5110612-2 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.