Unable to Complete TR Dynamic Disable Calibration with Driver Module Errors Due to the Driver Module.

Symptom

Unable to Complete TR Dynamic Disable Calibration with Driver Module Errors See Long Description System is a new 3T Excite HDx system being installed. The FE is unable to complete the TR Dynamic Disable Calibration due to the Driver Module errors shown below, which are logged on every attempt. Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150872 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD1 (Dynamic Disable Boards at Front of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150873 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD2 (Dynamic Disable Boards at Front of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD3 (Dynamic Disable Boards at Back of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the BD4 (Dynamic Disable Boards at Back of Body Coil) path. Check for disconnected cables and run the calibration again.-> Thu Jan 24 15:10:39 2008 2252359 2 gemr diagCoord Trdd_Calib 2254 Diagnostic: DCB Diag Iteration: 1 of 1 Action: 1 Task ID: 0x3fc42e0 Time: 150874 Object: SCP Function: RF: RF Bias T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive inside the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again.->

Error message

2252359 Driver Module has detected a potential open circuit in the DD Direct Drive inside the Body Hybrid Assembly path Error: 2252359 T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive ins ide the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again.-> Error: 2252359 T/R DD Calibration Failure. Driver Module has detected a potential open circuit in the DD (Direct Drive inside the Body Hybrid Assembly) path. Check for disconnected cables and run the calibration again. 2252358 on 11.0 and OPENMR4 is changing to 2252359 on 11.1 and OPENMR4a sw. 2252359 has been used on 12.0, 14.0, HDe 14.0 E2, G3, and OPENMR5 sw.

Applies to

Models
Excite
Product
3T Excite HDx 14.0 Software. The software that this solution is tied to is indicated by the Software concept below.
Software
14.0 For both Excite HDx and 3T Excite HDx systems.
Component
SecondOpinion Excite HD & HDx Driver Module 5110612-2 See comments in resolution concept for second opinion requirements before ordering this part
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.