Unable to Load Solaris Operating System on SPARC Ultra2 Computer.
Symptom
Unable to Load Solaris Operating System on SPARC Ultra2 Computer See Long Description. Version 2.5.1 Rev.11/97 Solaris would stop loading after the load process accessed the Auto-install floppy. The floppy drive was cleaned and operating normally (access LED had activity). HDD was replaced which prompted the Load-From-Cold. CD-ROM drive was working because questions pertaining to time zone, networking, etc would appear and accept input. These questions are extracted from the Solaris CD which is mounted in the CD drive. All replacement drives must be labeled before loading Solaris.
Error message
Warning Could not find matching rule in rules. ok This message appears in a pop-up window during the Solaris load at the point when the floppy drive is accessed. Full message as follows; "Searching for JumpStart directory… rules.ok found on floppy. Copying information to disk... Using rules.ok from floppy. Checking rules.ok file... Warning: Could not find matching rule in rules.ok Press the return key for an interactive Solaris install program.." "Searching for JumpStart directory… rules.ok found on floppy. Copying information to disk... Usingles.ok from floppy. Checking rules.ok file... Warning: Could not find matching rule in rules.ok Press the return key for an interactive Solaris install program.."
Applies to
- Product
- Profile 3 Ultrasparc CPU with AN8290Y gradients
- Software
- Profile Contour 7.67 Applies to Profile1 through 4 and Contour1 through 4. This is the last revision of software for this product line. Requires 7.66 LFC. 7.67 is a patch.
- Component
- 2317555-2 HDD Must use 5197352 Auto Label floppy with this HDD. See SN64588 for Profile3-4 to determine correct Auto-Install floppy. See SN64591 for Profile1-2 to determine HDD jumper settings and correct AutoInstall floppy part number.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- OrthoMRI Network cable is unplugged
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- CWA ID100060 Unable To Film.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.