Unable to Load Solaris Operating System on SPARC Ultra2 Computer.
Symptom
Unable to Load Solaris Operating System on SPARC Ultra2 Computer See Long Description. Version 2.5.1 Rev.11/97 Solaris would stop loading after the load process accessed the Auto-install floppy. The floppy drive was cleaned and operating normally (access LED had activity). HDD was replaced which prompted the Load-From-Cold. CD-ROM drive was working because questions pertaining to time zone, networking, etc would appear and accept input. These questions are extracted from the Solaris CD which is mounted in the CD drive. All replacement drives must be labeled before loading Solaris.
Error message
Warning Could not find matching rule in rules. ok This message appears in a pop-up window during the Solaris load at the point when the floppy drive is accessed. Full message as follows; "Searching for JumpStart directory… rules.ok found on floppy. Copying information to disk... Using rules.ok from floppy. Checking rules.ok file... Warning: Could not find matching rule in rules.ok Press the return key for an interactive Solaris install program.." "Searching for JumpStart directory… rules.ok found on floppy. Copying information to disk... Usingles.ok from floppy. Checking rules.ok file... Warning: Could not find matching rule in rules.ok Press the return key for an interactive Solaris install program.."
Applies to
- Product
- Profile 3 Ultrasparc CPU with AN8290Y gradients
- Software
- Profile Contour 7.67 Applies to Profile1 through 4 and Contour1 through 4. This is the last revision of software for this product line. Requires 7.66 LFC. 7.67 is a patch.
- Component
- 2317555-2 HDD Must use 5197352 Auto Label floppy with this HDD. See SN64588 for Profile3-4 to determine correct Auto-Install floppy. See SN64591 for Profile1-2 to determine HDD jumper settings and correct AutoInstall floppy part number.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.