Unable to Scan using the MRID 1.5T T/R Knee/Foot Coil due to error Multicoil Bias Fault Detected Open Circuit.
Symptom
Unable to Scan using the MRID 1.5T T/R Knee/Foot Coil with Multicoil Bias Fault Detected Open Circuit The FE had just replaced the MRID 1.5T T/R Knee/Foot Coil's cable: "MRID 1.5T KNEE/FOOT CABLE W/COIL ID" part number 2293674-13 when this problem began. Every time a scan is attempted using this coil, the prescan fails with the error shown below logged: 2252301 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 Channel 5 of 16, counting from 1 Value: 163 mA Limit: 348 mA Mask of all failed channels: 0x10-> The FE had just replaced the MRID 1.5T T/R Knee/Foot Coil's cable: "MRID 1.5T KNEE/FOOT CABLE W/COIL ID" part number 2293674-13 when this problem began. Every time a scan is attempted using this coil, the prescan fails with the error shown below logged: 2252301 SIG213 NSP SCP:DCB 779 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 Channel 5 of 16, counting from 1 Value: 163 mA Limit: 348 mA Mask of all failed channels: 0x10-> Note: The errors shown below are also seen logged at the same time as the error code 2252301, but these are a consequence of error code 2252301. On systems equipped with both a Driver Module and an SSM (as on 11x systems) there is a race condition, with faults reported by the Driver Module causing a false reporting of both Head and Body Path Open faults from the SSM. The Driver Module fault is the only real fault here. Once it is fixed, the other faults will also disappear. When encountering this situation always work on the Driver Module fault first. 2249149 SIG213 NSP SCP:../TrDriverMdsHWO.cpp 1286 T/R driver fault, head path open Possibly a disconnected cable between the driver board and the head T/R network, or an open diode in the head T/R switch. EN 268 2249151 SIG213 NSP SCP:../TrDriverMdsHWO.cpp 1302 T/R driver fault, Body Path open. Possibly a disconnected cable between the driver board and the body T/R network, or an open diode in the body T/R switch.
Error message
2252301 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCDx Channel x of y, counting from 1 Value x mA Limit y mA See Long Description for Extended Error 2252301 MRI_GB_OW0 NSP SCP:DCB 816 Multicoil Bias Fault Detected - Open Circuit. Try re-seating all coil connectors. MCD1 (or MCD2) Channel 1 of 16, counting from 1 Value: 2 mA Limit: 298 mA Mask of failed channels: 0x1 Ch 1-8 : Legacy MC Conn Ch 17-24 : Conn A Ch 25-32 : Conn B-> Extended Error: This fault was detected by the Driver Module. An open circuit fault occurs when the actual value is less than the pre-defined limit. Check system cables, connectors, coils and configurations. Re-seat all coil connectors. The mask of all failed channels indicates additional channels with the same fault - convert the hex number to a bitmap to decipher the mask, with channel 1 indicated by the least significant bit and channel 16 indicated by the most significant bit. For example, a mask of 0x3c converts to 0011 1100, meaning channels 3, 4, 5, and 6 all experienced the same failure. The key at the bottom of the error message shows the MC driver bias channels provided by the Driver Module used with each mult
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- 2293674-13 is the Cable for MRID Knee/Foot PA Extremity coil 2293674-2
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.